Logs 

 

STi 270 

                   07631 

 

STi 310  

    

       07632 

 

STi 360 

 

       07632 

 

Fasteners 

Self Tapping Screws-#8 

       08510 

Self Tapping Screws-#10 

       08515 

Hardware Package 

 

       08600 

Door Hooks   

 

       04081 

Door Springs   

 

       04082 

Tinnerman Clips 

 

       05149 

Door Hinges   

 

       06095 

Bullet Catches  

 

       04079 

 

Venting Components 

Appliance Adaptor 

 

       29700 

 

Gaskets 

Pilot Assembly Gasket 

       05100 

Burner Supply Line Gasket         05105 
Thermal Fan Switch Gasket         05101 
Appliance Adapter Gasket 

       29701 

 
For current prices and policies covering 
replacement parts, contact the factory or your 
Alpine distributor or dealer.  Parts will be 
supplied at current prices.  To order parts, you 
must have the following information: 
 
1.  The model number of the appliance. 
2.  The part number. 
3.  A description of the part. 
4.  The purchase date of the appliance. 
 
If you have any questions or problems, contact 
your local distributor/dealer or: 
 

Alpine Gas Fireplaces 

782 West State Street 

Lehi, Utah 84043 

(801) 768-8411

 

 

GAS PARTS

  

SIT Control Valve       

     04036 

Flexible Gas Line Connector       04048 
Burner Supply Line w/ Fittings   05114 

Burner Orifice 

STi 270NG  04054        STi 270LP  04099 
STi 310NG  05112        STi 310LP  04102 
STi 360NG  05113        STi 360LP  05111 
Pilot Assembly 

 

     04038 

Thermocouple  

 

     04040 

Thermopile   

 

     04041 

Propane Pilot Orifice   

     05082 

Burner 

 

STi 270 

 

     03200 

 

STi 310  

 

     03201 

 

STi 360 

 

     03202 

 

 

 

     

Electrical Parts 

Fan 

 

      

      

     08218 

KB Switch 

 

 

     09232 

 

Thermal Fan Switch   

     08222 

Piezo Ignitor Button    

     04046 

Thermostat (Wall Mount) 

     08260 

Wall Switch   

 

     08255 

Wire (Wall Switch/Thermostat)  08255 
 

Face Trim, Logs, Fan Accessories 

Glass - STi 270  

 

     06182 

 

STi 310                            06138 

 

STi 360 

 

     06184 

Glass Gasket   

 

     07840 

Face Trim Frame (3 Pieces)        
Brass Knob W/Screw  

     04032 

 
 
 
Face Pieces 

 STi 

270 STi 

310 STi 

360 

Top  32130  

33130  

34130 

Left  32135  

33135  

34135 

Right  32140  

33140  

34140 

B.F.   32145  

33145  

34145 

Doors

 

 STi 

270 STi 

310 STi 

360 

Valve 32065  

33065  

34065 

Vent  32820  

33820  

34820 

REPLACEMENT PARTS INFORMATION 

Содержание STi - LP

Страница 1: ... life Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life INSTALLER PLEASE LEAVE THIS MANUAL WITH THE CUSTOMER HOMEOWNER PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE These gas appliances have been tested in accordance with National Safety Standards and have been certified by Warnock Hersey for installation operation as...

Страница 2: ...14 Log Replacement 14 Normal Operating Sounds 15 Clearance Information 16 Instruction Plate 17 Troubleshooting Guide 18 Replacement Parts List 19 Exploded View 20 Warranty Information 21 IMPORTANT SAVE THESE INSTRUCTIONS The STi Series Direct Vent Fireplace must be installed in accordance with these instructions Carefully read all the instructions in this manual first Consult the authority having ...

Страница 3: ...e with the manufacturer s installation instructions and with local codes if any if not follow the current ANSI Z223 1 in the USA Electrical supply 120VAC 50 Amps 60Hz NOT FOR USE WITH SOLID FUEL This vented gas fireplace is not to be used with air filters Alpine Gas Fire places Lehi Utah Field Converted Put Label Here Clearances to Combustibles Unless Specified Side Wall from glass frame A 10 Ceil...

Страница 4: ...ther flammable vapors and liquids 13 If the pilot goes out for any reason turn the control knob to the off position Wait five minutes before attempting to re light pilot 14 Never obstruct the flow of ventilation and combustion air to the fireplace Always be sure the vent termination and air inlets remain clear and open INSTALLATION REQUIREMENTS BEFORE YOU START NOTE TO BUILDING CODE OFFICIALS The ...

Страница 5: ...ugh the damper or has excessive bends it must be removed 7 Plan gas piping and routing see Routing Gas Piping to Fireplace on page 6 MINIMUM FIREPLACE OPENING Model Width Height Depth STi 270 27 5 20 5 16 75 STi 310 31 5 23 16 75 STi 360 36 5 25 16 75 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system whe...

Страница 6: ... or rough handling will allow he glass to fall out of the trim 6 Set the trim aside so that it will not get damaged during the installation process Removing the Appliance Adapter The appliance may have been shipped with the Appliance Adapter installed Gently remove the adapter by sliding it to the rear of the appliance See figure 2 Take great care not to damage the white adapter gasket If the Gask...

Страница 7: ...Alpine STi Series Gas Fireplaces 7 CHIMNEY LINERS COMBUSTION AIR DAMPER FLASHING COMBUSTION AIR VENT LINER ...

Страница 8: ... 3 7 Push the liner onto the nipple that flows through the adapter until it seats against the gasket material 8 Fasten the liner to the adapter with 3 4 sheet metal screws 9 Lower the liner for combustion air and fasten it to the co linear adapter in the same manner as the vent liner to the remaining nipple 10 Lower the adapter onto the flashing and fasten with sheet metal screws through the tabs ...

Страница 9: ...through the fan control switch the thermostatic on off switch and also the blower motor itself These switches are connected in series or end to end GROUNDING NOTE Star Washer must be placed between base material and closed loop connector Note Be sure to protect the hearth with cardboard thin plywood or light sheet metal to prevent the inset from marring or scratching the hearth Figure 5 Connecting...

Страница 10: ...They must be located in these positions to avoid combustion related problems GAS REQUIREMENTS LOG PLACEMENT ADJUSTMENTS UNIT TESTING AND ADJUSTMENTS AERATION ADJUSTMENT Pilot Light Adjustment The pilot light is preset at the factory and should require no adjustment The flame on the pilot should project about 5 8 past the pilot head with enough flame to impinge on both the thermocouple on the left ...

Страница 11: ... See fig 9B A dark orange flame with sooting and black smoke indicates a lack of primary air The primary air shutter is located in the firebox on the right hand side of the burner Adjust the primary mixture by loosening the set screw on the air shutter and increasing the opening for more air and a bluer cleaner flame or by closing the air shutter for a more yellow flame See figure 10 The primary a...

Страница 12: ...d to meet an individual comfort level Note On cold start up of the fireplace the pilot should be allowed to run for at least five minutes to start a draw and to allow the thermopile time to heat up before turning the fireplace on Note There may be air in the gas line that needs to be purged out when first lighting the appliance Note If the pilot will not stay lit after several tries turn the gas c...

Страница 13: ... technician to inspect the appliance and to replace any part of the control system and any gas control which have been under water 7 If the venting system is disassembled for any reason it must be properly resealed as per the instructions in the venting section of this manual Never operate the appliance if the venting system is not properly sealed GOLD or NICKEL TRIMS The gold plate or nickel trim...

Страница 14: ... In the event that you break your glass by impact purchase your replacement from an authorized Alpine dealer See the replacement parts list for ordering information Follow the replacement steps below CAUTION Never use an open flame to check for gas leaks Always use a soap solution to check for leaks 3 Remove all loose or damaged glass from the frame 4 Insert the new glass panel with the gasket pre...

Страница 15: ...ed air throughout your home It is not unusual for the fan to make a rushing air sound when it is on This sound will increase and decrease in volume depending on the speed of setting of your blower controller Metal Firebox The firebox is made of a high quality steel Steel by its very nature expands and contracts as it heats and cools You will often hear a ticking or clicking sounds as the appliance...

Страница 16: ...tel Clearance C See Figure 15 16 Mantle Depth D See Figure 15 16 Hearth Height E 0 Hearth Depth F 16 Minimum Hearth Width G 48 CLEARANCE REQUIREMENTS CLEARANCE REQUIREMENTS Fig 15 Mantel Clearance Fig 14 Insert Clearances 0 2 4 6 8 10 12 10 12 14 16 18 23 side view of fireplace 3 1 2 mantel 8 mantel 12 mantel top of fireplace faceplate top ...

Страница 17: ...nder water This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air CAUTION Hot while in operation Do not touch Keep children clothing furniture gasoline and other liquids having flammable vapors away Keep burner and control compartment clean See installation and operating instructions accompanying appliance LIGHTIN...

Страница 18: ...opile and thermocouple are fully inserted into pilot bracket Check switch wires to make sure they are not grounding Check thermopile with millivolt meter Take reading at thermopile terminals of valve TP TPTH Should read 325 millivolts circuit open minimum while thermopile has pilot flame on it With the pilot ignited turn valve knob to on Take reading at TP TPTH with on off switch in on position Re...

Страница 19: ...ntact your local distributor dealer or Alpine Gas Fireplaces 782 West State Street Lehi Utah 84043 801 768 8411 GAS PARTS SIT Control Valve 04036 Flexible Gas Line Connector 04048 Burner Supply Line w Fittings 05114 Burner Orifice STi 270NG 04054 STi 270LP 04099 STi 310NG 05112 STi 310LP 04102 STi 360NG 05113 STi 360LP 05111 Pilot Assembly 04038 Thermocouple 04040 Thermopile 04041 Propane Pilot Or...

Страница 20: ...Alpine STi Series Gas Fireplaces 20 EXPLODED VIEW Termination Cap 09317 Venting Adapter 09318 Band Clamp 08530 3 Aluminum Venting 09400 Appliance Adapter 29700 Band Clamp 08530 Adapter Gasket 29701 ...

Страница 21: ... provided that the purchaser shall pay a reasonable charge for the transportation of the serviceman and needed parts and equipment from the nearest Alpine service center to the location of the appliance and return LIMITATIONS These one year and limited lifetime warranties are in lieu of all other express warranties ALL IMPLIED WARRANTIES INCLUDING ANY IM PLIED WARRANTIES OF MERCHANTABILITY OR OF F...

Отзывы: