background image

33

041-036-B000-001, Rev. A (07/2013)

7.0   Warranty And Consumer Information

ALPHA GENERATOR WARRANTY
Generators are covered by this warranty from the date of original retail purchase for a period of 1 year for 

residential use and 6 months for commercial applications. Units used in rental fleets, reconditioned or as 

demonstration models will be considered commercial usage. The warranty coverage is continual from the original 

date of purchase, and does not restart upon the replacement of any part or complete unit. Individual parts 

replaced at any point during the warranty period are only eligible for warranty coverage for the balance of the 

original warranty period.
Eligibility
To be eligible for warranty replacement, the product must be purchased in the United States or Canada from 

an authorized Coast Distribution dealer. This warranty applies to the original retail purchaser only, and is not 

transferable. Proof of purchase and the serial number is required.
Coverage
Pre-approved parts and labor costs will be covered by Alpha for any failure that is proven to be a failure in 

material or workmanship under normal use during the applicable warranty time period. This coverage is limited 

to parts, labor and ground shipping of repair parts. It is the responsibility of the end user to return the product 

to the nearest authorized repair center as directed by the warranty administration center. If in the event that the 

generator is deemed to be not repairable or the necessary repair would be economically unfeasible, the warranty 

department will authorize its prepaid return to the nearest Coast Distribution location and Coast will prepay the 

returned shipping to the dealer, repair center or consumer. The Coast Distribution System, Inc. reserves the right 

to repair or replace any part or unit at its option. The Coast Distribution System, Inc. may request defective parts 

to be returned. Anything replaced under warranty becomes the property of The Coast Distribution system, Inc.
To Obtain Warranty Service
Do not return this generator to the store where you purchased it. Contact any authorized dealer or contact our 

national customer service center at: 

Phone: 1-877-544-4449 (8am to 6pm ET)

Fax: 1-800-263-0280

E-mail: [email protected]

If contacting us by fax or e-mail, be sure to include a description of the problem as well as all return contact info 

such as address, phone number, fax number, e-mail, etc. Engine serial number, barcode number and proof of 

purchase are required.
Exclusions

This warranty does not extend to parts affected or damaged by accident and/or collision, normal wear, fuel 

contamination or degradation, use in an application for which the product was not designed or any other misuse, 

neglect, incorporation or use of unsuitable attachments or parts, unauthorized alteration, or any causes other than 

defects in material or workmanship of the product. This warranty does not extend to normal maintenance items 

such as belts, hoses, spark plugs, wheels and filters past the first scheduled replacement or service interval for 

these items whichever comes first.

Disclaimer of Consequential Damage and Limitation of Implied Warranties
THE COAST DISTRIBUTION SYSTEM, INC. DENIES ANY RESPONSIBILITY FOR LOSS OF TIME OR 

USE OF THE PRODUCT, TRANSPORTATION, COMMERCIAL LOSS, OR ANY OTHER INCIDENTAL OR 

CONSEQUENTIAL DAMAGE. ANY IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THIS 

WRITTEN LIMITED WARRANTY.

Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or 

limitation of incidental or consequential damages. Therefore, the above exclusions and limitations may not apply 

to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to 

state.
Replacement Parts Availability
To purchase replacement parts please refer to the www.powerhouse-products.com website.

Содержание ACX2000i

Страница 1: ...AlphaGen ACX2000i 120V Portable Generator Operation Manual Effective July 2013...

Страница 2: ...s fumes safety information to PREVENT INJURY OR DEATH to the technician or user WARNING FUMES HAZARD FIRE HAZARD WARNING provides flammability safety information to PREVENT INJURY OR DEATH to the tech...

Страница 3: ...er or improperly maintained Photographs and drawings in this manual are for illustrative purposes only and might not exactly match your installation Review this manual before proceeding If there are q...

Страница 4: ...m 19 2 12 Economy Switch 19 2 13 Stopping the Engine 20 3 0 Maintenance 21 3 1 Emission Control System 21 3 2 Maintenance Schedule 22 3 3 Changing Oil 23 3 4 Servicing the Air Cleaner 24 3 5 Spark Plu...

Страница 5: ...verload LED Location 16 Figure 2 8 Battery Charging 17 Figure 2 9 Circuit Breaker Location 18 Figure 2 10 Low Oil Alarm LED Location 19 Figure 2 11 Economy Switch Location 19 Figure 2 12 Engine Switch...

Страница 6: ...ring the generator indoors WARNING FUMES FIRE HAZARD Generators are a potential source of electrical shocks when misused do NOT operate wet conditions WARNING ELECTRICAL HAZARD Do not operate the gene...

Страница 7: ...generator Keep all accessories in a convenient location for future use or reference Battery Charge Kit Oil Jug Oil Drain Pipe Quick Start Guide Screwdriver Spare Spark Plug Spark Plug Wrench Spark Plu...

Страница 8: ...panel is removed The bar code number label is found in three locations On the side of the generator near the fuel valve On the back of this manual The BCN number is on the foil label on the shipping c...

Страница 9: ...c oil is approved for use in Alpha generators generally and is recommended when operating the generator in temperatures below 32 F Use synthetic oil to fill the oil well of the generator and use it fo...

Страница 10: ...ed If any undesirable operating symptoms appear while using a gasoline that contains ethanol replace it with a gasoline that has the proper blend CAUTION Use automotive unleaded regular gasoline only...

Страница 11: ...ead Screwdriver Procedure 1 Remove the maintenance cover 2 Remove the three screws from the air cleaner Remove the cover to check the element Clean or replace as necessary see Section 3 4 for details...

Страница 12: ...uel tank was empty it may be necessary to pump the primer bulb 7 times to get fuel to the carburetor 2 Turn the engine switch ON 3 Move the choke lever to the START position 4 Pull the starter grip li...

Страница 13: ...s engine damage caused by an excessively lean air fuel mixture CAUTION 2 6 Operating at Extreme Temperatures High temperature adversely affects generator operation Generator performance will decrease...

Страница 14: ...ions for standby power to Alpha equipment should only be made by authorized and qualified personnel Do not connect the generator to an automatic transfer device or severe damage may result WARNING ELE...

Страница 15: ...before connecting them to the generator If the equipment begins to operate abnormally becomes sluggish or stops suddenly turn off the generator engine switch immediately Disconnect the equipment and e...

Страница 16: ...erload LED Location The total wattage of all equipment connected must be considered Do not exceed the current limit specified for any one receptacle Do not modify this generator or use it for purposes...

Страница 17: ...nd sparks if you make accidental contact between a battery terminal and the vehicle s frame or body Connect the positive charging cord to the positive battery terminal Do not reverse the charging cabl...

Страница 18: ...mmediately If swallowed drink large quantities of water or milk and follow with milk of magnesia or vegetable oil Call a physician immediately KEEP OUT OF REACH OF CHILDREN WARNING ELECTRICAL HAZARD T...

Страница 19: ...automatically when the electrical load is disconnected and returns to the proper speed to match the power of the electrical load when the load is reconnected Turning the Economy switch OFF disables th...

Страница 20: ...ut disconnecting all loads can cause damage to the generator or equipment Continually stopping the generator with a load applied can lead to damage of the control module CAUTION Normal Shutdown 1 Turn...

Страница 21: ...standards The regulations dictate that the manufacturer provides operation and maintenance standards regarding the emission control system Tune up specifications are provided in Section 6 0 Specifica...

Страница 22: ...s or 50 Hours Every 6 Months or 100 Hours Once per Year or 300 Hours Engine Oil Check x Change x x Air Cleaner Check x Clean x Spark Plug Clean Adjust x Spark Arrester Clean x Fuel Filter Check x Repl...

Страница 23: ...on the dipstick 6 Reinstall the dipstick and then the maintenance cover and tighten the screws securely Recommended oil is SAE 15W 40 when ambient temperature is above 32 F 0 C Synthetic SAE 0W 40 is...

Страница 24: ...TION 1 Loosen the panel screws and remove the side maintenance panel 2 Remove three air cleaner retaining screws Remove the air cleaner cover and check the air cleaner element Clean or replace the ele...

Страница 25: ...any dirt from around the spark plug base 4 Use the supplied wrench to remove the spark plug 5 Visually inspect the spark plug Discard it if the insulator is cracked or chipped 6 Clean the spark plug w...

Страница 26: ...cap on the spark plug securely 12 Reinstall the spark plug maintenance cover The spark plug must be securely tightened An improperly tightened plug can become very hot and possibly damage the generat...

Страница 27: ...issue unless you drop the arrester or the clamp or screws behind the grill Taking the grill off or leaving it on is a matter of your convenience but the procedure below will include removing the grill...

Страница 28: ...breakdown and the formation of gum and varnish and to inhibit corrosion in the fuel system and carburetor CAUTION 1 Be sure the storage area is free of excessive humidity and dust 2 It is best to keep...

Страница 29: ...Exercising the Generator It is essential that the generator be exercised on a regular basis This will prevent the accumulation of varnish or sludge in the fuel system remove moisture from the generat...

Страница 30: ...tch on Is there a spark from the spark plug Is there fuel in the tank Refuel the fuel tank NO YES To check spark 1 Remove the spark plug cap and clean any dirt from around the spark plug 2 Remove the...

Страница 31: ...he electrical equipment to an electrical shop for repair NO NO YES YES YES Is the circuit breaker and ON Reset the circuit breaker NO 33 2000Wi OM Take the generator to an authorized Powerhouse servic...

Страница 32: ...00 RPM with economy switch off Ignition system Electronic Spark plug A7RTC Starting system Recoil Fuel Automotive unleaded gasoline Lube oil synthetic or conventional SAE 15W 40 0W 40 for extreme cold...

Страница 33: ...Inc may request defective parts to be returned Anything replaced under warranty becomes the property of The Coast Distribution system Inc To Obtain Warranty Service Do not return this generator to th...

Страница 34: ...s If any emissions related part on your engine is defective the part will be repaired or replaced by The Coast Distribution System Inc Owner s Warranty Responsibilities As the SORE owner you are respo...

Страница 35: ...System Carburetor including the choke system and replaceable high altitude main jets Engine speed control system Economy Throttle Intake manifold Engine control module Evaporative Control System Fuel...

Страница 36: ...ou read and follow the instructions provided exactly c To reduce risk of battery explosion follow these instructions and those marked on the battery d Never smoke or allow an open spark or flame in th...

Страница 37: ...ip to carburetor fuel lines or sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block vii Connect charger ac supply cord to electric outlet and viii When disconnecting...

Страница 38: ...667 8743 Alpha Technologies GmbH Hansastrasse 8 D 91126 Schwabach Germany Tel 49 9122 79889 0 Fax 49 9122 79889 21 Alphatec Ltd 339 St Andrews St Suite 101 Andrea Chambers P O Box 56468 3307 Limassol...