3 & 5 Amp Models
Fig. 1-1, Main Features of the XM3.1-HP Series Power Supply
1.0 Overview
The XM3.1-HP provides Outputs 1 & 2 for powering broadband devices and one auxiliary output for powering ancillary
devices in the enclosure. The output voltage for Output 1 and 2 are dependent on the model of the power supply and
the location of the Vout Selection Tap. The output voltage of Auxiliary Output 1 is dependent on the model. See page
5 for model numbers and their corresponding output voltages. The XM3.1-HP is composed of the following embedded
modules:
Transformer Module —
provides a critical load with current-limited regulated AC power that is free of spikes, surges,
sags and noise.
Power Processing Module (PPM) —
contains circuits for the Inverter, Sensing, Relays and Input/Output power.
Power Control Module (PCM) —
controls the core power supply functions such as Line Mode (AC Input), Inverter,
Battery Charger, Data Storage and AC Output.
Element Monitoring Module (EMM) —
is the interface between the Power Control Module and the Cable Modem Module
(CMM). The EMM provides the necessary data storage and performs advanced functions such as logging power supply
events, utility events, and battery health analysis. Additionally, the EMM provides the interface for the local web page and
logic for the ancillary equipment such as tamper switches.
NOTE: Should the EMM be removed, the Smart Display will
be disabled.
Cable Modem Module (CMM) —
interfaces with the EMM to provide the necessary communication over the DOCSIS
®
and Ethernet networks. The CMM enables the local Ethernet port for local web server access. The CMM may be removed
from the power supply along with the EMM.
NOTE: Smart Display functionality will cease until the EMM is installed.
1
Line Cord IEC Input
9
Alarm LED
17 Ethernet (ETH) Connector
25 SFP Port
2
Aux Output, 110Vac/220Vac, RMS
10
Self-Test Button
18 LNK: CPE Link Status
3
Output 1 [Voltage set by V
out
Selection]
11
Local/Remote Indicator (LRI) Connector
19 Alarm / Ready
4
Output 2 [Voltage set by V
out
Selection]
12
Precision Temperature Sensor (PTS) Connector
20 RF Connector for CMM
5
V
out
Selection Tap Terminal Block
13
Cable Modem Power (PWR) Indicator
21 Rx/Tx Power Indicator
6
Smart Display
14
Tamper (TPR) Switch Connector
22 Battery Input 12V
7
Soft Keys
15
Environmental Control Connector
23 External Ground Connection
8
Output LED
16
Upstream/Downstream Indicator for CMM
24 Folding Handle
This power supply has been approved by regulatory authorities which require its use with Alpha
®
enclosures.
Refer to Section 8.
ATTENTION:
Introduction
This guide describes the XM3.1-HP power supply (3 and 5 Amp models) and provides procedures with regard to the
installation of the power supply, battery connection, the Smart Display, initial startup and test, battery configuration and
verification of successful installation. For detailed information, refer to the XM3.1-HP Broadband UPS™ Technical Manual
for 3 & 5 Amp Models
(Alpha p/n 017-947-B0-001)
available at www.alpha.com.
This guide is intended for experienced, qualified and licensed installation personnel familiar with the mechanical and
electrical requirements of power supply enclosure systems. Review the XM3.1-HP Broadband UPS™ 3 & 5 Amp
Technical Manual
and other support documentation on the website to become familiar with the features and functions of
the equipment in this system before proceeding. Failure to install and/or use this equipment as instructed in the system
documents can result in a hazard to personnel or damage to the equipment. Once installation is complete, only qualified
personnel should service the system.
1
Line Cord IEC Input
10 Self-Test Button
19 Alarm / Ready
2
Aux Output, 110VAC/220VAC, RMS
11 Local/Remote Indicator (LRI) Connector
20 RF Connector for CMM
3
Output 1 [Voltage set by V
out
Selection]
12 Precision Temperature Sensor (PTS) Connector
21 Rx/Tx Power Indicator
4
Output 2 [Voltage set by V
out
Selection]
13 Cable Modem Power (PWR) Indicator
22 Battery Input 12V
5
V
out
Selection Tap Terminal Block
14 Tamper (TPR) Switch Connector
23 External Ground Connection
6
Smart Display
15 Environmental Control Connector
24 Folding Handle
7
Soft Keys
16 Upstream/Downstream Indicator for CMM
25 SFP Port
8
Output LED
17 Ethernet (ETH) Connector
9
Alarm LED
18 LNK: CPE Link Status
™
3
4
5
2
1
24
23
LEFT SIDE
FRONT
3
4
5
2
1
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
CMM
EMM
PPM
25
PCM