Alpha CD24/32 - Contents/Introduction
CONTENTS
1
Introduction ....................................... 2
2
Technical data ................................... 3
3
General boiler information .................. 7
4
Installation ......................................... 13
5
Commissioning ................................. 20
6
Boiler operation ................................. 23
7
Routine servicing ............................... 24
8
Component replacement ................... 26
9
Wiring diagrams ................................ 33
10 Fault finding ...................................... 36
11 Short parts list ................................... 41
12 Service history .................................. 42
The Alpha CD range of high efficiency condensing boilers are wall mounted, fan assisted room-sealed boilers. The burner is lit
electronically and the heat output is controlled by a modulating fan and gas valve.
The CD24C and CD32C are combination boilers providing both central heating and domestic hot water at mains pressure. The
CD24S is a system boiler providing heating only for sealed central heating systems.
The boilers are supplied with a pump, pressure relief valve, expansion vessel and pressure gauge fully assembled and tested.
They are designed for use with a fully pumped, sealed and pressurised central heating system using only Natural gas.
The CD24C and CD24S boilers are suitable for central heating loads of between 4.9 and 25.4 kW (16 700 and 86 700 Btu/h).
The CD32C boiler is suitable for central heating loads of between 6.5 and 29.8 kw (22 200 and 101 700 Btu/h).
The maximum output available for domestic hot water is 24.2 kW (82 600 Btu/h), capable of providing 9.6 litres/min with a
temperature rise of 35°C for the Alpha CD24C boiler and for the Alpha CD32C boiler - 32 kW (109 200 Btu/h), providing 13.2
litres/min with a temperature rise of 35°C.
IMPORTANT
It is the law that all gas appliances are installed by a competent person, ie CORGI registered personnel, in accordance with
the following recommendations:-
Current Gas Safety (Installation and Use) Regulations
All relevant Building Regulations issued by the Department of the Environment
Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Department
UK Water Regulations/Byelaws (Scotland)
Health & Safety Document No. 635 (The Electricity At Work Regulations 1989)
The installation should also be in accordance with the following British Standard Codes of Practice:-
BS 5440:1:2000
Flues
BS 5449:1990
Forced circulation hot water systems
BS 5546:2000
Installation of hot water supplies for domestic purposes
BS 6700:1997
Design, installation, testing and maintenance of services supplying water
BS 6798:2000
Installation of gas fired hot water boilers
BS 6891:1998
Gas installation
BS 7593:1992
Code of Practice for treatment of water in heating systems
BS 7671:2001
Requirements for electrical installations, IEE Wiring Regulations
If installation is in a timber framed building, refer to the Institute of Gas Engineers document IGE/UP/7.
This appliance meets the requirements of IPX4D, ie degree of protection against moisture.
Failure to install this appliance correctly could lead to prosecution. It is in your own interest and that of safety to ensure that the
law is complied with.
Manufacturer's instructions must NOT be taken in anyway as over-riding statutory obligations.
Note: Ensure that the Benchmark Log Book has been completed after the boiler has been installed and commissioned.