background image

 

 

G    S    M        D  O  O  R        I  N  T  E  R  C  O  M

 

GDI Bell 

 
 
 

 

 

User and programming manual V 2.6 

 

 

Содержание GDI Bell

Страница 1: ...G S M D O O R I N T E R C O M GDI Bell User and programming manual V 2 6 ...

Страница 2: ...s operation the GSM network is used therefore you don t need any telephone line or other cables Model with 1 or 2 buttons Under each button you can program up to 7 phone numbers After pressing the button the numbers are dialled progressively Automatic regulation of microphone volume 2 independent remotely controlled switching relays with different ways of activation activation by ringing or by cod...

Страница 3: ...for saved numbers only GDI might also reject incoming calls see later in relay function Before picks up might GDI alert by preprogrammed melody adjustable Notification for call establishing listen in control 2 remotely controlled switching relay Each can be controlled up settings by different ways 1 By ringing incoming call is rejected confirmation of command accept and simoultaneously is activate...

Страница 4: ...ted It might be programmed 1 number only ON OFF Then is send 1 SMS only up selected status 2 opening detection When input is activated during call for example by gate door opening the GDI generates into a call 3 short beeps for time of input activation Voice signalling of different status Up settings might be different status signalling by voice language adjustable When is voice signalling present...

Страница 5: ...4 Assembly of front panel CAUTION During assembly of the front panel may be needed to connect disconnect the speaker connector see schematics ...

Страница 6: ...5 GDI Wall mounting Wall mounting assembly you make by attached screws 5mm ...

Страница 7: ...6 Cards inserting name labels Every button has an individual card holder with a plastic flag see the figure below ...

Страница 8: ...ts and connection Switch For operation put to position ON SIM reader For operation insert the SIM Setting of speaker loudness Loudness is also possible setup by parametr input Relay 2 Relay 1 PSU Speaker screw terminal ...

Страница 9: ...se 2x independent PSU One for GDI and second for electrical locks The electrical lock 2 is connected inversaly fire emergency doors 3 External camera or lighting activation 4 Electrical lock and additional bell combination CAUTION Relay contacts cant close 230V directly To control directly 230V devices you must use contactor 1 2 3 4 ...

Страница 10: ...insert the SIM We recommend use SIM without PIN When you need PIN setup PIN 1234 Release the SIM holder 1 Move it up 2 Insert the SIM in correct position 3 to the holder Close the SIM holder 4 Pull the SIM holder for lock up 5 1 2 3 4 ...

Страница 11: ...ile under name ADMIN1 4 On the SIM save phone number which should be dial after pressing button 1 A under name ABUTTON1 5 When you have GDI with 2 numbers save on the SIM also phone number which will be dial after pressing button 2 B under name BBUTTON1 6 When you want dial automatically next numbers when first number is busy or not available then save those numbers under appropriate names ABUTTON...

Страница 12: ... not preprogrammed then first step is SIM programming via following article 3 and then try connection After voice connection you can adjust setting of speaker volume Then screw up front panel of GDI 3 Programm GDI parametres The parametres in GDI must be switch on you can programm by 2 ways By SMS or by PC special sw via USB port A Programming by SMS Due security reasons you can programm GDI param...

Страница 13: ...format WRITE ABUTTON1 420xxxxxxxxx WRITE BBUTTON1 etc 4 Up your needs send next SMS with other parametres for opening by ringing SMS alarm sending etc 5 Setup parametres GDI via table Parametres you can setup individually for each parametr appropriate SMS When you need setup more parametres simoultaneously we recommend use SMS for batch setting By SMS READ PAR read firstly current setting to your ...

Страница 14: ...p appropriate port 4 Program control GDI connection After that display GSM signal strength and voltage on GDI back up ACU Now you can programm Monitor mode For parametres programming stop firmware running in GDI For operation monitoring dont press Stop GDI running Identification of seriál line connection After GDI voice connection will show voltage in GDI After GDI voice connection will show GSM s...

Страница 15: ... sends to GDI command for stop and wait for GDI response via After click to button monitor is shown GDI operation when operation is not stoped by button STOP Record savings from monitor to file for service purposes record sending Waiting for GDI response ...

Страница 16: ...pper button Saving of all programmed parametres including numbers to GDI Reading of all programmed parametres including numbers from GDI Saving of all programmed parametres including numbers to PC Reading of all programmed parametres including numbers from PC GDIset version and fw GDI SIM number of position Field to programm up to 7 phone numbers for second button GSM provider where is GDI registr...

Страница 17: ... Phone Book Phone book of authorised numbers for ringing opening as same as automatic call receiving Position for name Position for phone number Add line above cursor Delete line with cursor Find inserted name ...

Страница 18: ...tting Way of incoming call receiving reject opening by ringing automaticaly picked up calls from numbers at list only pick up all calls Signalization Informing GDI tones Ringing during incoming call Voice signalling Waiting Call Waiting to dial the next number on the list of button ...

Страница 19: ...Parametres setting for relay 2 Relay mode camera light button control by SMS Relay control by ringing only from SIM phone numbers DTMF code for relay activation during a call Relay time of activation Relay control by ringing from all phone numbers ...

Страница 20: ...ber where will be sent SMS ALARM OFF when input is deactivated Input mode Input deactivated Tones when input is activated during a call open signal sending SMS Sending SMS to ADMIN1 with list of numbers which activated relay by ringing Activation of time settings from GSM network ...

Страница 21: ...20 Item ADMIN numbers setting Field to save up to 7 ADMIN numbers ...

Страница 22: ...ON Unauthorised manipulation can blocked the unit List of files you want record to GDI manually editable Reading of list from PC List erasing Start of files saving from list to GDI Indicator shows the process of savings Select and play ringing tone Savings of selected ringing tone to GDI ...

Страница 23: ...eturn from programming mode to monitor mode restart of GDI GDI behaviour after restart is the same like during power supply connection tones eventually voice messages To return to monitor mode run GDI click on button Run Programm detects GDI runs the same way like stop ...

Страница 24: ...elay 1 SET REL1 OFF Deactivation relay 1 SET REL1 ON xx Activation relay1 for xx minutes xx 00 99 SET REL2 ON Activation relay 2 SET REL2 OFF Deactivation relay 2 SET REL2 ON xx Activation relay 2 for xx minutes xx 00 99 WRITE JMENO 420cc c Saving of phone number under NAME WRITE PAR VOLIN x Saving of microphone loudness x 1 7 4 WRITE PAR VOLOUT x Saving of speaker loudness x 1 7 4 WRITE PAR INCAL...

Страница 25: ...SMS 0 WRITE PAR WAIT xx Waiting to dial the next number on the list xx 10 to 90 sec by dozens 20 SMS might be sent from ADMINx numbers only WRITE PAR RL1COD y Code for relay1 activation during call y 0 9 5 WRITE PAR RL1MOD x Relay 1 modes x 0 control by SMS x 1 switch mode ringing in only from SIM phone number or by code x 2 camera mode activated by pick up deactivated by hang up x 3 lighting mode...

Страница 26: ...ck up deactivated by hang up x 3 lighting mode activated by pick up and stays ON for activation time after hang up x 4 activated for activation time after button press x 5 switch mode all ringing in from all phone number or by code 0 WRITE PAR RL2TMON yy Relay2 activation time after ringing in or by code yy seconds yy 00 99 05 WRITE PAR RL2RING x Relay2 activation by ringing in x 0 OFF x 1 ON 0 WR...

Страница 27: ...st stayed otherwise remote settings will not be possible neccessary to make new initialization INIT Initialization During first setting when SIM doesnt includes any ADMINx number is neccessary to put such number on the SIM card It is done by SMS with INIT command The SMS might be sent from various number When SIM card already has at least one number with name ADMINx the command is ignored WRITE co...

Страница 28: ...this number is called from GDI when number under ABUTTON3 is busy unreachable not picked up a call for certain relay1 or relay2 activated by ringing in calls are automatically received from this number ABUTTON5 to this number is called from GDI when number under ABUTTON4 is busy unreachable not picked up a call for certain time relay1 or relay2 activated by ringing in calls are automatically recei...

Страница 29: ...lled from GDI when number under BBUTTON3 is busy unreachable not picked up a call for certain time relay1 or relay2 activated by ringing in calls are automatically received from this number BBUTTON5 to this number is called from GDI when number under BBUTTON4 is busy unreachable not picked up a call for certain time relay1 or relay2 activated by ringing in calls are automatically received from thi...

Страница 30: ...ay2 activated by ringing in calls are automatically received from this number ALARMON to this number is send SMS ALARM ON when input is activated against ground ALARMOFF to this number is send SMS ALARM OFF when input is deactivated VER firmware version in GDI just info do not adjust PARGDI GDI parametres A B C D E F G H default 4 4 0 0 1 5 0 0 A microphone sensitivity 1 7 B speaker loudness 1 7 C...

Страница 31: ...l activated by ringing in all phone numbers or by DTMF code during call CC activation time 00 99 D relay activation by ringing in 0 deactivated 1 activated PARRL2 parametres for relay 2 A B CC D default 6 0 05 0 A DTMF code for relay activation during call 0 9 B relay mode 0 SMS mode control by SMS 1 switch mode activated by ringing in from SIM phone numbers or by DTMF code during call 2 camera mo...

Страница 32: ...S READ STAT READ STATUS VER 101 BATTERY 4030mV TIME 00 01 01 00 01 55 OPER T Mobile CZ INP 1 RL1 0 RL1 0 GDI response for SMS READ PAR READ PAR VOLIN 4 VOLOUT 4 INCALL 0 WRCALL 1 TMGSM 1 TONE 5 INPMOD 2 WAIT 20 RL1COD 5 RL1MOD 4 RL1TMON 03 RL1RING 1 RL2COD 6 RL2MOD 1 RL2TMON 05 RL2RING 1 SMS example for GDI parametres setting WRITE PAR VOLIN 1 TONE 7 INPMOD 2 RL1COD 2 ...

Страница 33: ...sages the GDI has own signalling of operation via setting possibilities High tone Alerting Medium level tone verify action Low level tone error High tone follow by medium level tones in period cca 5 sec High tone repeated Medium level tone repeated during button holding high tone High tone once after dial number to GSM ...

Страница 34: ...33 LED signalling Red LED Permanent light Not light Yellow LED Not light Flashing space and light same duration Short flashing with frequency 2 sec Permanent light ...

Страница 35: ...ve already GDI with a backup battery in the delivery pull out before operation insulating tape Do not store the device with a battery pack without insulating tape Self discharge can damage the battery not covered by the manufacturer s warranty ...

Страница 36: ...h are not covered warranty of manufacturer Use only batteries approved by the manufacturer Li Ion 14650 1600 mAh Observe the polarity Never place the inverted battery It can damage the device Attention to the polarity battery is cap isolated from the casing Before inserting the battery off GDI using the switch red LED goes out ...

Страница 37: ...36 ...

Страница 38: ...37 The manufacturer is not liable for defects caused by failure to comply with the prescribed procedure Technical parametres Again turn on GDI moving the switch to the ON position ...

Страница 39: ...rated ACU 1600mAh for cca 30h of operation Buttons 1 or 2 up casing for each button max 7 numbers progressively dialled Relay 2x switching contact Max voltage 48V when I 1A Max Current 2A when U 30V Activation time by code 1 to 99 sec Activation time by SMS 1 to 99 min Detection of start restart relay1 contact switch to 7s Input 0 5V GSM networks 850 900 1800 1900 MHz SIM 3V 1 8V ...

Страница 40: ...39 Alphatech Technologies s r o sales alphatechtechnologies cz www alphatechtechnologies cz ...

Отзывы: