![Alpha Technologies CFR 1500 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/alpha-technologies/cfr-1500/cfr-1500_operators-manual_2905900005.webp)
THE ALPHA CFR
i
IMPORTANT:
EMERGENCY SHUTDOWN PROCEDURE ON INSIDE BACK COVER
Table Of Contents
The Alpha CFR1500 and CFR 1500 RM
Uninteruptible Power Supplies
1.
INTRODUCTION ............................................................................ 1
1.1
The Alpha CFR
1
1.2
The CFR Advantage
2
1.3
Unpacking and Inspection
4
2.
FEATURES .................................................................................... 5
2.1
A Tour of the CFR
5
2.2
The CFR Front Panel
5
2.3
CFR Rear Panel
6
2.4
Information Management Options
8
Standard Interface Device
Intelligent Interface Device
External Modem
2.5
Communication / Interface Options
10
2.6
RS-232 Communication Options
15
RS–232 Connector
Rear Panel RS–232 Port
Terminal Emulation Setup
Connecting an External Modem
Desktop IID RS–232 Por t
3.
INSTALLATION ........................................................................... 18
3.1
Pre-Installation
18
Site Preparation
Utility Circuit Breaker
Grounding
Standby Generators
3.2
Connecting the CFR (Plug and receptacle)
19
3.2.1
Terminal Block Input and Output Wiring
20
3.3
External Battery Pack
22
3.4
208 VAC vs 240 VAC (60 Hz) Configurations
23
4.
OPERATION ................................................................................ 26
4.1
Start-up, Test and Shutdown
26
4.2
External Modem Configuration
29
Specifications
Enabling External Modem
Configuring the modem to work with CFR
74
7.1
Specifications
,
continued
Common Specifications
Input Frequency
60 Hz or 50 Hz (± 3%)
Input Voltage Variation
- 20% to + 10%
Output Frequency
± 0.1 Hz (inverter mode)
Output Regulation
± 1%
Efficiency @Typical Load
90%
Total Harmonic Distortion
< 5%
Output Waveform
Sine
Step Load Response
< 10% @ 100% load
Noise Attenuation
Common Mode
-120dB (100K - 1 MHz)
Normal Mode
-60dB (100K - 1 MHz)
Low Voltage Trigger
80% nominal voltage (adjustable)
High Voltage Trigger
110% nominal voltage (adjustable)
Batteries
Valve regulated, maintenance-free
Battery Voltage
48 VDC
Batt. Low Volt. Cutout
39 VDC (>25% load), [42 VDC (<25% load)]
Battery Recharge Time
5.0 hrs.
Charger
Linear
(3 A max.)
Charger Voltage
55.2 VDC at 25°C (adjustable)
Operating Temp
32°-104° F / 0°-40°C
Heat Output
574 BTU/h; 168 W
Audible Noise @ 1M
CFR 1500
< 40dBA
CFR 1500RM
< 50 dBA
Indicators
Line Present, Line Failure,
Low Battery Shutdown,
Low Battery Warning (LED / audible alarm),
Test, Service and Output Load
Controls
Manual Start / Test, Alarm OFF
Connectors
AC Input, AC Output, External Alarm;
Intelligent Interface Device and
External Battery
Output Alarms
Rear panel RJ-45 connector (Form C
contact closures rated 1A, 30 V) for
Line Present / Line Failure, and
Battery OK / Low Battery Warning
Specifications subject to shange without notice
7. SPECIFICATIONS