background image

17

Subject to technical amendments without notice  |  83059700gUK – Translation of the operating manual |  ait-deutschland GmbH

Technical data/Scope of supply

LWP 450AR3

LWP450AR3

bis 10 (7)

-22   I   35

 10   I   40

dB(A)

-

dB(A)

dB(A)

-

dB(A)

dB(A)

m³/h

15000 (9000)

-

l/h

bar  I  bar  I  l/h

bar

kg

kg  I  kg  I  kg

-

-

14B

kW  I  kW  I  kW

W

im Lieferumfang: • ja    — nein

—   I   —

im Lieferumfang: • ja    — nein

—   I   —

integriert: • ja    — nein

—   I   —

Schwingungsentkopplungen Heizkreis 

integriert: • ja    — nein

  •

integriert: • ja    — nein

  •

integriert: • ja    — nein

  •

Performance data

At A7/W35 per EN14511

At A7/W45 per EN14511

At A2/W35 per EN14511

At A10/W35 per EN14511

At A-7/W35 per EN14511

At A-15/W65 per EN14511

At A-7/W55 per EN 14511

At A35/W18

At A35/W7

Operating limits

°C

°C

Heat source, heating

min. I max.

°C

Heat source, cooling

min. I max.

°C

additional operating points

Sound

Sound pressure level at 1 m distance from edge of unit

Inside

Max.

dB(A)

Sound pressure level at 1 m distance from edge of unit

Outside

Max.

dB(A)

Sound power level

Inside

Max.

dB(A)

Sound power level

Outside

Max.

dB(A)

Sound power level per EN12102

dB(A)

Heat source

Air flow rate at maximum external pressure

m³/h

Maximum external pressure

Pa

Heating circuit

Volume flow rate: minimal   I   nominal    I   maximal

l/h

Free pressing I Pressure loss I   Volume flow rate

bar  I  bar  I  l/h

max. allowable operating pressure

bar

General unit data

Total weight 

kg

Weight, individual components

kg  I  kg  I  kg

Electrics

Degree of protection

IP

Electric heating element output

3  I  2  I  1 phase

kW  I  kW  I  kW

Circulation pump power consumption, heating circuit

min. — max.

W

Other unit information

Heating circuit safety valve  

included in scope of supply: • yes    — no

Heating circuit expansion vessel 

included in scope of supply: • yes    — no

Overflow valve I   Changeover valve, heating -Domestic hot water

integrated: • yes    — no

Heating circuit vibration decouplers 

integrated: • yes    — no

Controller

integrated: • yes    — no

Heat quantity recording

integrated: • yes    — no

1 Compressor values in brackets

Содержание LWP Series

Страница 1: ...UK 83059700gUK Translation of the operating manual Air water heat pumps Operating Manual LWP...

Страница 2: ...cope of supply 8 5 2 Storage 8 5 3 Unpacking and transport 8 5 4 Installation 9 5 5 Noise 10 6 Hydraulic installation 12 6 1 Condensate drain 13 7 Electrical installation 14 OXVKLQJ OOLQJ DQG YHQWLQJ...

Страница 3: ...l hydraulic integration Operating manual of the heating and heat pump controller Brief description of the heat pump controller Operating manual of the expansion board Log book 1 3 Symbols and markings...

Страница 4: ...ies and damage to property Ensure that personnel are familiar with local regulations especially those on safe and hazard aware working OORZ TXDOL HG SHUVRQQHO ZLWK HOHFWULFDO WUDLQLQJ only to carry ou...

Страница 5: ...ystems Proper planning design and commissioning Closed system with regard to corrosion Integration of an adequately dimensioned pressure maintaining device Use of demineralised heating water or VDI 20...

Страница 6: ...sides 3 2 Wall mounted controller The box with the wall mounted controller is located at the bottom right in the device 3 3 Layout NOTE This section essentially names the FRPSRQHQWV UHOHYDQW IRU IXO O...

Страница 7: ...is hereby discharged to the heating water and is used in the heating circuit The liquid refrigerant at a high pressure and high temperature is depressurised expansion valve The pressure and temperatur...

Страница 8: ...cutting your hands on sharp edges of the device Wear cut resistant protective gloves The hydraulic connections are not designed for mechanical loads Do not lift or transport the device by the hydraul...

Страница 9: ...ice 2 Dispose of the transport and packaging material in an environmentally friendly way and in accordance with local regulations 5 4 Installation Set up and connection CAUTION In the air outlet area...

Страница 10: ...r unit model 7HFKQLFDO GDWD VFRSH RI VXSSO RYHUYLHZ HDWLQJ FLUFXLW VHFWLRQ RQQHFW WKH XQLW WR WKH HG SLSLQJ RI WKH KHDWLQJ circuit via vibration decouplers You must install them to prevent the transfe...

Страница 11: ...lectrical cables ATTENTION Irreparable damage to the compressor due to wrong URWDWLQJ HOG QVXUH WKDW WKHUH LV D FORFNZLVH URWDWLQJ HOG IRU the compressor load infeed Basic information about the electr...

Страница 12: ...HYHQWLQJ damage in hot water heating systems Required pH value 8 2 10 for aluminium materials pH value 8 2 8 5 Fill the system only with demineralised heating water VE water or VDI 2035 water low salt...

Страница 13: ...or the integration of storage tanks in series Complete the work steps quickly otherwise the maximum return temperature may be exceeded and the heat pump switches to high pressure fault 7XUQ WKH DGMXVW...

Страница 14: ...epartment In other countries Send notice of completion for heat pump systems and rough checklist to the manufacturer s local partner 4 Arrange for the heat pump system to be commissioned by after sale...

Страница 15: ...3 Faults Read out the cause of the fault via the diagnostics program of the heating and heat pump controller Contact the local partner of the manufacturer or the factory s customer service Have the fa...

Страница 16: ...16 Subject to technical amendments without notice 83059700gUK Translation of the operating manual ait deutschland GmbH...

Страница 17: ...nd pressure level at 1 m distance from edge of unit Outside Max dB A Sound power level Inside Max dB A Sound power level Outside Max dB A Sound power level per EN12102 dB A Heat source Air flow rate a...

Страница 18: ...t pump VD Compressor Temp Hot water temperature Flow Return 823279a 10 15 20 25 30 35 40 45 50 55 60 65 70 75 22 17 12 7 2 3 8 13 18 23 28 33 Temp C Qh kW 35 C 1VD 55 C 1VD 35 C 2VD 55 C 2VD 1 2 3 4 5...

Страница 19: ...SDFLW LQGH p Pressure loss heat pump VD Compressor 823279a 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 15 20 25 30 35 40 Temp C Q0 kW 7 C 1VD 18 C 1VD...

Страница 20: ...leranz Allgemein DIN ISO 2768 cL Oberfl chen ArtikelNr Dimensioned drawing LWP Item Name 1 Horizontal connection area water condensate 2 Vertical connection area water condensate feed through electric...

Отзывы: