3  Intended use

The unit may be used only for the intended use. This 

means:

 

● for heating.

 

● for heating hot water.

The unit may be operated only within its technical pa

-

rameters.

  “Technical  data / scope  of  delivery“,  from 

page 22

 NOTE

Notify the responsible power supply company 

of the use of a heat pump or heat pump sys

-

tem.

 

CAUTION

The unit is not suitable for use in IT network 

systems.

Exclusion of liability

The manufacturer will not be liable for damage result

-

ing from unauthorized use of the unit.
The manufacturer’s liability will also be voided in the 

following cases:

 

● if work is performed on the unit and its compo

-

nents in a manner that does not comply with the 

terms of this operating manual;

 

● if work is performed on the unit and its compo

-

nents in an improper manner;

 

● if work is performed on the unit that is not de

-

scribed in this operating manual, and this work 

was  not  expressly  approved  in  writing  by  the 

manufacturer;

 

● if the unit or components in the unit are modi

-

fied, redesigned or removed without the express 

written permission of the manufacturer.

EC conformity

The unit bears the CE mark of conformity.

  “EC declaration of conformity”, page 43

Safety

The unit is safe to operate when used for its intended 

purpose.  The  construction  and  design  of  the  unit 

conform  to  current  state-of-the-art  standards,  all 

relevant  DIN/VDE  regulations  and  all  relevant  safety 

regulations.
The operating manuals supplied with the product are 

intended for all users of the product.
The operation of the product via the heating and he

-

at pump control and work on the product which is in

-

tended for end customers / operators is suitable for all 

age groups of persons who are able to understand the 

activities and the resulting consequences and can car

-

ry out the necessary activities.
Children and adults who are not experienced in hand

-

ling the product and do not understand the necessa

-

ry activities and the resulting consequences must be 

instructed  and,  if  necessary,  supervised  by  persons 

experienced in handling the product and who are re

-

sponsible for safety.
Children must not play with the product.
The product may only be opened by qualified personnel.
All instructional information in this operating manual is 

solely directed at qualified, skilled personnel. 
Only  qualified,  skilled  personnel  is  able  to  carry  out 

the work on the unit safety and correctly. Interference 

by  unqualified  personnel  can  cause  life-threatening 

injuries and damage to property.

 

► Ensure that the personnel is familiar with the  local 

regulations, especially those on safe and hazard-

aware working.

 

► Only  allow  qualified  personnel  with  “electrical” 

training  to  carry  out  work  on  the  electrics  and 

electronics.

 

► Only  allow  qualified,  skilled  personnel  to  do  any 

other work on the system, e.g.

 

● Heating installer

 

● Plumbing installer

 

● Refrigeration  system  installer  (maintenance 

work)

Every person who carries out work on the unit must 

comply  with  the  applicable  accident  prevention  and 

safety  regulations.  This  applies  in  particular  to  the 

wearing of personal protective clothing.

Содержание LW 140A

Страница 1: ...UK 83054200iUK Air Water Heat Pumps Outdoor installation Operating Manual LW 140A LW 251A...

Страница 2: ...k on or operate the unit Treat all con stituent parts confidentially The information contained herein is protected by copyright No part of this oper ating manual may be reproduced transmitted copied s...

Страница 3: ...0 Circulating pumps 14 21 Water heating 14 22 Hot water tank 14 23 Electrical connections 15 24 Rinsing filling and bleeding the system 16 25 Insulating the hydraulic connections 17 26 Set the overflo...

Страница 4: ...The operating manuals supplied with the product are intended for all users of the product The operation of the product via the heating and he at pump control and work on the product which is in tende...

Страница 5: ...heat source Do not restrict or block the air conducting sides Dimensional drawings from page 27 and In stallation plans from page 29 for respective unit model WARNING Never switch on unit if air flow...

Страница 6: ...page 20 10 Operating principle of heat pumps Heat pumps operate on the principle of a refrigera tor the same technology only with the opposite effect The refrigerator extracts heat from foods which i...

Страница 7: ...ent through low emissions and reduced prima ry energy use You can operate and control the heat pump system with the control element of the heating and heat pump regulator NOTE Make sure that the contr...

Страница 8: ...very from page 22 Accessories necessary for operation IMPORTANT Use only original accessories from the manu facturer of the unit Heating and heat pump controllers as wall mounted controllers or integr...

Страница 9: ...area of the heat pump is permeable to water 16 2 Transport to installation site To prevent damage during transport always transport the unit to final installation site in its original packaging using...

Страница 10: ...st be lifted with a crane 1 Remove side laths on the wooden pallet 2 Guide lifting straps under the unit Insert laths or beams between the lifting straps and the unit in order to prevent damage to the...

Страница 11: ...the air flow baffles WARNING Unit has rotating parts For safety reasons mount the two air flow baffles on the unit before continuing with any other work 1 If you have not already done so remove lower...

Страница 12: ...nit and afterwards attach the lower facing pan els see Electrical connection work Heat pump side connection of control and sensor wires 6 4 Install air flow baffles IMPORTANT Remove the protective she...

Страница 13: ...nit 1 Install the outside pipes of the heating circuit be neath the frost line 2 Install shut off devices for the hot water outflow forward flow and hot water inflow return flow on the heat pump side...

Страница 14: ...Heating circuit section In mono energetic air water systems integrate the buf fer tank in the heating water outflow forward flow before the overflow valve 20 Circulating pumps CAUTION Always note the...

Страница 15: ...and sensor wires They are connected at the electric switch box on the switch box side of the heat pump 1 Screw control and sensor wires to the two con nectors on the side of the electric switch box 2...

Страница 16: ...2 8 5 Fill the system with deionised heating water VE water or with water corresponding to the VDI 2035 norm only low salt operation of the system 2 Guide control and sensor wires inside the unit thro...

Страница 17: ...itioning substances is of decisive importance Therefore they should be monitored regularly using appropriate water test equipment Rinsing filling and bleeding 1 Rinse and fill the heating circuit and...

Страница 18: ...t pump must be equipped with an all pole automatic circuit breaker with at least 3 mm contact spacing to IEC 60947 2 The heating circuit is flushed filled and thoroughly vented All valves and shut off...

Страница 19: ...ng to EU regulation EC 517 2014 leak inspections and maintenance of a log book are required by law for certain heat pumps Log book for heat pumps Section Information on use of the log book The compone...

Страница 20: ...electronic components in keeping with environmental considerations 29 Malfunctions In the event of a malfunction you can detect the cause of the malfunction via the diagnostic program of the heating a...

Страница 21: ...21 Subject to change without notice 83054200iUK ait deutschland GmbH...

Страница 22: ...l unit data Dimensions see dimensional drawing for the specified unit size unit size Total weight kg Connections Heating circuit Heat source Refrigerant Refrigerant type Quantity kg Free cross section...

Страница 23: ...9 6 3 813515d LW 251A 27 3 3 9 14 1 4 2 26 1 3 3 13 7 3 4 24 0 l 3 6 13 2 l 3 8 29 2 4 0 14 2 4 5 19 4 I 2 8 10 1 2 9 20 50 20 35 A 7 60 57 65 7800 2500 5000 6200 0 12 5000 5 540 R5 4 AG R407C 9 8 30...

Страница 24: ...22 24 26 28 30 20 15 10 5 0 5 10 15 20 25 30 35 Temp C 35 C 1VD 50 C 1VD COP 1 2 3 4 5 6 7 20 15 10 5 0 5 10 15 20 25 30 35 Temp C Pe kW 2 3 4 5 6 20 15 10 5 0 5 10 15 20 25 30 35 Temp C p bar 0 0 0...

Страница 25: ...28 30 32 34 36 20 15 10 5 0 5 10 15 20 25 30 35 Temp C 35 C 1VD 50 C 1VD 35 C 2VD 50 C 2VD COP 1 2 3 4 5 6 7 20 15 10 5 0 5 10 15 20 25 30 35 Temp C Pe kW 2 3 4 5 6 7 8 9 10 20 15 10 5 0 5 10 15 20 2...

Страница 26: ...0 42 44 46 48 20 15 10 5 0 5 10 15 20 25 30 35 Temp C 35 C 1VD 50 C 1VD 35 C 2VD 50 C 2VD COP 1 2 3 4 5 6 7 20 15 10 5 0 5 10 15 20 25 30 35 Temp C Pe kW 2 3 4 5 6 7 8 9 10 11 12 13 20 15 10 5 0 5 10...

Страница 27: ...rlauf R 1 1 4 2 Heizwasser Eintritt R cklauf R 1 1 4 3 Kondensatschlauch Au en 36x3 4 Grundplatte LR Luftrichtung A B 4 3 2 1 A B C D E F 4 3 2 1 Zust nde Schutzvermerk ISO 16016 beachten M 0 Key UK81...

Страница 28: ...uf R 1 1 4 2 Heizwasser Eintritt R cklauf R 1 1 4 3 Kondensatschlauch Au en 36x3 4 Grundplatte LR Luftrichtung A B 5 4 3 2 1 A B C D E F 4 3 2 1 Zust nderungste Schutzvermerk ISO 16016 beachten M 007...

Страница 29: ...3 2 1 a Zust P P Legend UK819377a All dimensions in mm A Front view C Top view Minimum clearances 1 Recess in base 2 Local heat pipe for heating water forward return flow 3 Empty pipe for electric cab...

Страница 30: ...N 34 beachten A B C D E F 4 3 2 1 Zus Legend UK819378 All dimensions in mm A Front view C Top view Minimum clearances 1 Recess in base 2 Local heat pipe for heating water forward return flow 3 Empty p...

Страница 31: ...t be ob served facing away from the coast prevailing wind direction 9 in a sheltered area near a wall 9 not in open areas 9 not in sandy surroundings to avoid the influx of sand on the seaward side 9...

Страница 32: ...32 Subject to change without notice 83054200iUK ait deutschland GmbH LW 140A LW 251A Row tank...

Страница 33: ...33 Subject to change without notice 83054200iUK ait deutschland GmbH Separate buffer tank LW 140A LW 251A...

Страница 34: ...mfort board Expansion board 29 Dirt trap 0 6 mm mesh 15 Mixer circuit three way mixer MK2 3 discharge r o t a l u g e r e c n e r e f f i d e r u t a r e p m e T 7 1 l a n o i t p o g n i l o o c r o...

Страница 35: ...1 TB1 9 B10 A MA1 MIS GND TA Function EVU 1 N PE 230V 50Hz GND TRL Overload protection internally wired TB1 L1 TA A1 HUP Heat pump Cut out controller unit X52 PE 10 3 N PE 400V 50Hz 6 HUP UK831170 A2...

Страница 36: ...Distribution box power supply additional heating Terminal in switch box heat pump Q5 E22 817333c X8 Q1 Q11 3 M1 S10 Q1 E20 1 G1 F3 E23 F4 X10 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 1...

Страница 37: ...mperature limiter heating element Terminal in switch box heat pump Plug on switch box heat pump control line Plug on switch box heat pump gauge line R51 817333c X10 F1 Q1 1800 Ohm 3 74 kOhm 6 19 kOhm...

Страница 38: ...n box power supply output compressor Distribution box power supply additional heating Terminal in switch box heat pump Q5 E22 817334c X8 Q1 Q11 3 M1 S10 Q1 E20 Q2 Q21 3 M2 S11 Q2 E21 1 G1 F3 E23 F4 X1...

Страница 39: ...ating element Terminal in switch box heat pump Plug on switch box heat pump control line Plug on switch box heat pump gauge line 817334c X10 F1 Q1 1960 Ohm 3 74 kOhm 6 19 kOhm Q2 K3 X10 K10 STB Q5 F2...

Страница 40: ...n box power supply output compressor Distribution box power supply additional heating Terminal in switch box heat pump Q5 E22 817344c X8 Q1 Q11 3 M1 S10 Q1 E20 Q2 Q21 3 M2 S11 Q2 E21 1 G1 F3 E23 F4 X1...

Страница 41: ...nal in switch box heat pump Plug on switch box heat pump control line K5 817344c K4 X10 R50 4 64 kOhm 5 62 kOhm 7 50 kOhm R51 R52 X10 F1 Q1 Q2 K3 K4 K5 X10 K10 STB Q5 F2 B10 1 2 3 4 5 6 7 8 1 2 8 A B...

Страница 42: ...sensor Hot gas sensor Encoding resistor Plug on switch box heat pump gauge line 817344c R5 R6 2200 Ohm R3 X10 R10 R2 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 3 3 3 4 5 6 7 AIT 817344 Str...

Страница 43: ...15031941 100545 15031941 LW 81A HT 1 LW 101A HT 2 LW 121A HT 2 LW 140A HT 2 100543 15031941 Designated position confirms that the following designated device s as designed and marketed by us fulfill t...

Страница 44: ...ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf E info alpha innotec de W www alpha innotec de alpha innotec an ait deutschland GmbH brand UK...

Отзывы: