Make sure that pipes do not damage cable assemblies
and components in the unit.
Guide pipes carefully past cable assemblies and
components in the unit.
3. Guide pipes out through the holes on the water
connection side.
4. Lift unit by the pipes, with at least four persons,
and place on the base. Make sure that the frame
of the unit is in full contact with the underlying sur
-
face.
Lifting the unit with a crane
NOTE
The unit type LW 251A must be lifted with a
crane.
1. Remove side laths on the wooden pallet.
2. Guide lifting straps under the unit. Insert laths or
beams between the lifting straps and the unit in
order to prevent damage to the housing, or re
-
move facing panels (see removal instructions un
-
der “Attaching air flow baffles”).
A Front view (switch box side)
B Side view 1
DANGER
Lifting straps should not be too close to-
gether or too near the center; otherwise
the unit may tip!
C Side view 2
IMPORTANT
Guide lifting straps past the fan on the side.
Make sure the straps do not press against the
fan during transport.
3. Lift unit with the crane and place on the base.
Make sure that the frame of the unit is in full con
-
tact with base.
Содержание LW 140A
Страница 1: ...UK 83054200iUK Air Water Heat Pumps Outdoor installation Operating Manual LW 140A LW 251A...
Страница 21: ...21 Subject to change without notice 83054200iUK ait deutschland GmbH...
Страница 32: ...32 Subject to change without notice 83054200iUK ait deutschland GmbH LW 140A LW 251A Row tank...
Страница 33: ...33 Subject to change without notice 83054200iUK ait deutschland GmbH Separate buffer tank LW 140A LW 251A...