ATTENTION
Install the heat pump only outdoors and operate
only with outside air as the heat source. Do not
restrict or block the air-conducting sides.
Dimensional drawing and installation plan for re-
spective model.
WARNING!
Never switch on unit if air flow baffles on
the unit are removed.
ATTENTION
The integration of the heat pump in ventila-
tion systems is not permissible. The use of the
cooled air for cooling purposes is not permitted.
ATTENTION
The ambient air in the location where the heat-
ing pump is installed and also the intake air which
is used as a source of heat must not contain any
kind of corrosive components!
Components such as ammonia, sulphur, chlo-
rine, salt, sewer gas, flue gases etc. may cause
damage leading to complete failure or even a to-
tal write-off of the heating pump!
ATTENTION
By cooling with low flow temperatures, conden-
sate can be expected to form on the heat distri-
bution system as the temperature falls below the
dew point. If the heat distribution system is not
designed for these operating conditions, it must
be protected by appropriate safety devices, e.g.
dew point monitor (purchasable accessory).
NOTICE
If the heating surfaces are used for heating and
cooling, the control valves must be suitable for
heating and cooling.
In addition, a dew-point monitor should be used
for cooling.
WARNING!
In the air outlet area the air temperature
is ca. 5 K below the ambient temperature.
Under certain climatic conditions, there‑
fore, an ice layer can form in the air out‑
let area. Install the heat pump so that the
air blower does not blow in the direction
of footpaths.
Customer Services
For technical assistance, please contact your qualified
technician or the manufacturer’s local service partner.
For a current list and additional partners of the manufac-
turer, please visit
DE: www.alpha-innotec.de
EU: www.alpha-innotec.com
Warranty / Guarantee
For warranty and guarantee conditions, please refer to
the purchase documents.
NOTICE
Please contact your dealer concerning warran-
ties and guarantees.
Waste disposal
When decommissioning the unit, always comply with ap-
plicable laws, directives and standards for the recovery,
recycling and disposal of materials and components of
cooling units.