background image

30

Subject to change without notice  |  83031300dUK  |  ait-deutschland GmbH

-F

13

A1

A2

-K

13

-F1

4

A1

A2

-K

14

-F

10

-F

12

A1

A2

ZI

P

M

K14 K13

ZIP

ZW2

PE

ZW1

L3

5

ZW2

3~N/PE/400V/50Hz

X7

:L

,N

,P

E

Pow
er

 suppl
y c

ont
rol

ler

 230V

PE

PE

A4

ZW1

N

N

MZ1

N

L

PE

PE

BUP

-X7

TA

-X3

L1

N

A3

L2

N
N

5

GND

A5

M

ZW2

ZW2/SST

BU

P

PE

F1

0

TB1

TA

A1

L1

N

ame

ZW
2

RF

V

A1

ZW2
/SS

T

A2

VBO

MI

S

PE

-X2

4

TB1

-X0

M

A3

ZUP

HUP

MA1

F1

2

HUP

A

ir w

ater

 in

si

de 

PE

3~PE/400V/50Hz

MA
1/

MI

S

L1

X7

X7:

L1,

L2,

L3

,P

E

A2

EVU

RFV

EVU

TBW

MOT

FP1

Ter

mi

nal

s

VBO

B10 A

ZW1

TBW

ZW1

In

fo

rm

ati

on

 o

n f

us

es

 c

an

 b

e f

ou

nd

 in

 th

e t

ec

hn

ic

al 

da

ta

ZIP

M

ZUP

3~N/PE/400V/50Hz

F1

4

GND

2

A4

BUP

TRL

3

F1

3

MZ
1/

MI

S

-X4

ASD

1~N/PE/230V/50Hz

GND

TRL

M

OT

RFV

ZW1

A5

ZW
1

GND

HUP

TB1

FP1

ZUP

Le

ge

nd:

GND

N

L1

X0

-X

4

TA

PEX

TBW

EVU

GND

A

ux

iliar

y c

irc

ul

at

ion

 pump

cir

cul

ati

on

 pum

p

Control

signal

of

additional 

heat 

generator 1

Control

signal

of

additional

heat

generator

2

(alternative 

is general 

malfunction)

PEX

U

K83

11

65

Function

Controller 

board; 

Attention: 

I-max = 

6A/230VAC

Terminals

in

heat

pump

switchbox

Sub-distribution

unit

internal

installation

Hot
water

or

buffer

storage

tank

Hot
water

or

buffer

storage

tank

3-pol. Cut out 

compressor; Attention: Right-hand 

rot. 
field is 

mandatory!

Cut
out
controller

unit

Cut
out
auxiliary

heating 1

Cut
out
auxiliary

heating

2

Contactor

electric

heating

element 

buffer tank

Contactor

electric

heating

element

hot
water

or

 

buffer tank

Hot 
water circulating 

pump/switching 

valve

Energy

supplier

contact;

closed

on
release;

bridge

 

if 

no blocking interval

Pump

for
mixing

circuit

1

Heating

circuit

circulating pump

Charge/discharge/cooling

mixer

1 open

Charge/discharge/cooling

mixer

1

closed

Overload

protection;

internally

wired

No
function

Accessories:

Remote control

External

sensor

Sensor

mixing

circuit 1

Hot
water

gauge/thermostat

External

return

sensor

Ventilator;

internally

wired

Terminal

strips

on
controller 

board (see sticker)

Terminal

strip

in

switchbox

of

heat

pump;

N/PE

distribution 

for 
external 

230V units

Power

supply

compressor;

3x400V;

Important:

Clockwise

rotary

 

field

is

absolutely

necessary!

Ter

m

inal
 di

agr
am

 LW 250 /

 31

LU

X2

8311

65

A

chi

m

 P

fle

ger

04

.12

.20

09

-

PE

P 020
/2

009

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1/1

1

04

.12.
20

09

10

X5

38

 - 10
X53

9;

A

chi

m

 P

fleg

er

10X
466 -

 1

0X

46

7;

Bla

tt-N

r.

Zus

ta

nd

Ä

nder
ung

Bea

rb.

D

at

um

N

am
e

Bl

 v

on

 An
z

D

at

um

Terminal diagram

LW 300(L)

Содержание 10078702

Страница 1: ...UK 83031300dUK Air Water Heat Pumps Indoor installation Operating Manual LW 300 L...

Страница 2: ...Domestic hot water preparation 12 12 Domestic hot water tank 12 13 Electrical installation 13 14 Installation of the control unit 14 15 Installation and removal of the screen 15 15 2 Removing the scre...

Страница 3: ...ing manual of the heating and heat pump controller Brief description of the heat pump controller Operating manual of the Comfort board 2 0 accessories Log book 1 3 Symbols and markings Identification...

Страница 4: ...must be instructed and if necessary supervised by persons experienced in handling the product and who are re sponsible for safety Children must not play with the product The product may only be opene...

Страница 5: ...essed air if necessary Improper action Requirements for minimum scale and corrosion damage in hot water heating systems Proper planning design and commissioning Closed system with regard to corrosion...

Страница 6: ...eat pump side 3 2 Layout Basic components NOTE This section essentially names the compo nents relevant for fulfilling the tasks described in this operating manual The following figure shows an LW 300...

Страница 7: ...uid refrigerant at a high pressure and high tempera ture is depressurised expansion valve The pressure and temperature drop and the process begins again The heated heating water can be used for the do...

Страница 8: ...purposes and extend it to its original posi tions following transport 1 Unpack the unit Unpacking page 11 5 Scope of supply storage transport and installation IMPORTANT Damage to the housing and the u...

Страница 9: ...e facing panel upwards remove and set aside in a safe place 4 Then remove side facing panels from the unit too and store safely Example Removing the lower facade on the operating side Example Removing...

Страница 10: ...tain climatic conditions an ice lay er can therefore form in the air outlet area Install the heat pump such that the air blow er does not discharge into footpath areas Installation room and space requ...

Страница 11: ...ing 9 Connect the unit to the heating circuit according to the hydraulic diagram for the respective model 9 Cross sections and lengths of the pipes for the heating circuit are adequately dimensioned 9...

Страница 12: ...energetic air water systems integrate the buffer tank in the heating water outflow forward flow before the overflow valve 10 Circulating pumps NOTE Do not use regulated circulating pumps Circulating p...

Страница 13: ...s closed open the lower facing panel on the operating side 2 Open electrical switch box of unit 1 Electrical switch box 3 Lead power cable power cable for circulating pumps and cable for external temp...

Страница 14: ...ontrol unit down until it locks into posi tion 3 Stick the heating and heat pump regulator s con trol cable into the right bushing on the bottom of the control unit NOTE A connection to a computer or...

Страница 15: ...me of delivery 1 recess for control unit 2 logo 3 temporary cover 1 First insert the screen below in the provided slots on the facade 2 Beginning first on one side and moving upwards lock the screen s...

Страница 16: ...ed con sult a company specialising in the treatment of heating water Keep a system log for hot water heating systems in which relevant planning data is entered VDI 2035 16 2 Flush fill and vent the he...

Страница 17: ...up if the air ducts weather and or rain louvres have been installed and the facing panels are closed 9 Relevant planning design data of the system is documented in full 9 The relevant energy supply c...

Страница 18: ...im mediately Check regularly to ensure that the condensate can drain out of the unit freely without obstruc tion To this end check the condensate pan in the unit and the evaporator regularly for dirt...

Страница 19: ...ainst being switched back on again Collect all media safely Separate components by their materials 22 2 Disposal and recycling Dispose of environmentally hazardous media in accordance with local regul...

Страница 20: ...pressure bar 3 Circulation pump control range min I max l h Hot gas use Flow rate pipe dimensioning l h Free pressing Pressure loss Flow rate bar bar l h General unit data Total weight kg 490 Weight o...

Страница 21: ...30 35 Temp C Pe kW 0 000 0 025 0 050 0 075 0 100 0 125 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 m h p bar p 15 20 25 30 35 40 45 50 55 60 65 25 20 15 10 5 0 5 10 15 20 25 30 35 40 Temp C Temp C L...

Страница 22: ...B Side view from left D Side view from right E Rear view LR Air direction Pos Pos Designation Designation Dim LW 300 Dim LW 300 1 Control unit 2 Hot water outlet flow R 6 4 3 Hot water inlet return R...

Страница 23: ...Side view from left D Side view from right E Rear view LR Air direction Pos Pos Designation Designation Dim LW 300L Dim LW 300L 1 Control unit 2 Hot water outlet flow R 6 4 3 Hot water inlet return R...

Страница 24: ...bau im Lichtschacht Kippmass der W rmepumpe 2050mm Bezeichnung B1 Bei Fertigwandst rke 240 bis 320 B2 Bei Fertigwandst rke 240 bis 320 Bei Fertigwandst rke 320 bis 400 Bezeichnung 5 6 7 9 Bei Fertigwa...

Страница 25: ...au im Lichtschacht Kippmass der W rmepumpe 2050mm 9 B2 Bei Fertigwandst rke 240 bis 320 Bei Fertigwandst rke 320 bis 400 5 6 7 Bezeichnung Bezeichnung B1 Bei Fertigwandst rke 240 bis 320 Bei Fertigwan...

Страница 26: ...man die Luftkan le eink rzen Dies hat eine erhebliche Erh hung des Schalldruckpegels zur Folge Kippmass der W rmepumpe 2050mm 8 7 6 5 Bezeichnung Bezeichnung B2 Bei Fertigwandst rke 240 bis 320 Bei Fe...

Страница 27: ...he Erh hung des Schalldruckpegels zur Folge KA Kondensatablauf G Schnitt Einbau im Lichtschacht Kippmass der W rmepumpe 2050mm 6 7 9 Bezeichnung Bezeichnung B2 Bei Fertigwandst rke 240 bis 320 Bei Fer...

Страница 28: ...28 Subject to change without notice 83031300dUK ait deutschland GmbH Separation buffer tank LW 300 L...

Страница 29: ...mfort board Expansion board 29 Dirt trap 0 6 mm mesh 15 Mixer circuit three way mixer MK2 3 discharge r o t a l u g e r e c n e r e f f i d e r u t a r e p m e T 7 1 l a n o i t p o g n i l o o c r o...

Страница 30: ...er storage tank Hot water or buffer storage tank 3 pol Cut out compressor Attention Right hand rot field is mandatory Cut out controller unit Cut out auxiliary heating 1 Cut out auxiliary heating 2 Co...

Страница 31: ...er supply output compressor clockwise rotary field is absolutely necessary Sump heating for compressor 1 Sump heating for compressor 2 Nozzle heating fan Motor protection fan Fan fuse 6 3 A Fan Contac...

Страница 32: ...compressor X10 L X10 X10 N X10 PE EVU A1 X10 2 X10 3 X10 X10 4 X10 Legend UK 817456 Controller board Attention I max 6 3A 230VAC Defrosting pressostat Energy supplier contact closed on release bridge...

Страница 33: ...EFS KEINE BERSETZUNG A1 Equipement Function A1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 TWE TWA TRL TVL THG TA TBW RVF CW TB1 Sensor mixing circuit 1 TA TBW RFV TB1 TWE TWA TRL TVL THG CW Legend UK 817456 Con...

Страница 34: ...34 Subject to change without notice 83031300dUK ait deutschland GmbH...

Страница 35: ...35 Subject to change without notice 83031300dUK ait deutschland GmbH...

Страница 36: ...ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf E info alpha innotec de W www alpha innotec de alpha innotec an ait deutschland GmbH brand UK...

Отзывы: