2.3 

Accessing Programing Mode 

In o

rder to access “Programing” mode, consecutively execute the following actions. 

1. Install the SIM card as shown in diag. 5. 

 

Caution! 

Prior to installing or removing the SIM card, it is necessary to de-activate the GSM Relay 

Sensor Alarm Switch electrical supply! (i.e. install the protective plastic battery insert or remove the 
battery). 
 

2. Remove the Protective Plastic battery Insert from in between the contacts and the battery 

(see diag. 5) or install a battery using correct polarity (if previously removed). 
 

 

 

Diagram 5: SIM card installation and protective plastic battery insert  removal 

 

3. The GSM Relay Sensor Alarm Switch 

LED indicator will glow red. The “GSM” LED will glow 

for 3 seconds and will begin to flash quickly. 
 

4. Wait for the SIM card to register on to the GSM network. At the conclusion of registration, 3 

beeps will be heard and the “GSM” LED will flash (1) once every (4) four seconds. The GSM Relay 
Sensor Alarm Switch LED indicator will glow green. This indicates that the GSM Relay Sensor 
Alarm Switch 

has entered “Programing” mode. During the entire duration of the “Programing” 

mode, the LED indicator will glow green. 
 

In the event the “GSM” LED continues to flash quickly, (the SIM card is not registering on the 

GSM network) and might be due to the SIM card being incorrectly or not installed, blocked by a PIN 
code or the GSM network is inaccessible (take steps in accordance with table 5). 

Upon  entering  “Programing”  mode,  the  GSM  Relay  Sensor  Alarm  Switch  sends  an  SMS 

notification  with  settings  to  the  primary  notification  telephone  number  (if  the  primary  number  was 
previously recorded in the SIM card memory). 

For the span of (1) one minute, the GSM Relay Sensor Alarm Switch 

remains in “Programing” 

mode and stands by for an incoming call and/  or  SMS containing any changes to the settings. In 
the absence of an incoming call/ SMS, the GSM Relay Sensor Alarm Switch at the expiration of (1) 
one minute enters “Armed On Guard” mode. 

In the event of an incoming call/ SMS occurring and being accepted,  the GSM  Relay  Sensor 

Alarm  Switch 

at  the  expiration  of  (1)  one  minute,  will  enter  “Armed  On  Guard”  mode  and  will 

transmit  an  SMS  notification  reflecting  the  setting  changes  to  the  primary  registered  telephone 
number. 
 

Содержание polus gsm

Страница 1: ...3 ...

Страница 2: ... 1 5 Operation of the GSM Relay Sensor Alarm Switch 7 2 Set Up 8 2 1 Preparing the GSM Relay Sensor Alarm Switch for operation 8 2 2 Configuring the GSM Relay Sensor Alarm Switch 8 2 3 Accessing Programing mode 10 2 4 Setting up for First Time Use 11 2 5 Verifying set up 11 2 6 Changing Adjusting the Parameters 12 2 7 GSM Relay Sensor Alarm Switch Installation 13 3 Troubleshooting the POLUS GSM Re...

Страница 3: ...Programming Armed On Guard POLUS GSM Relay Sensor Alarm Switch FEATURES Installs at any location with mobile GSM reception Arms and Disarms by simply turning power ON or OFF Settings programmable via mobile telephone online and thru utilizing Configurator Express GSM Android iOS apps or the GSM Central Control Monitoring Panel Uses two interface languages English and Russian Operates on a single 3...

Страница 4: ...ns do not exceed 109x32x27 5 mm Relay Sensor Alarm Switch w battery weight does not exceed 60 g Note The Relay Sensor Alarm Switch is capable of operating at temperatures below 25 C but the battery operating life will be reduced as well as the number of transmitted SMS notifications 1 4 Relay Sensor Alarm Switch Design The Relay Sensor Alarm Switch unit consists of a cover body with a LED indicato...

Страница 5: ...sor Alarm Switch contacts The two color LED s indicate the state of the Relay Sensor Alarm Switch in accordance with table 3 The GSM module circuit board contains a SIM cardholder XS3 and a GSM LED to indicate network signal strength Diagram 3 Exposed view of the controller circuit board and GSM module The Relay Sensor Alarm Switch ships with an installed battery insulated from the battery contact...

Страница 6: ...all the settings are completed the Relay Sensor Alarm Switch enters Armed On Guard mode While in Armed On Guard mode and when triggered by inputvia terminal block X2 causing a change in the position of the Relay Switch contacts Opened Closed the Relay Switch will enter ALARM mode and will then execute notifications via SMS and or by placing outgoing calls After concluding ALARM notifications the R...

Страница 7: ...ine is busy When the subscriber is out of network Calling out will cease after one of the subscriber numbers picks up and disconnects then the GSM Relay Sensor Alarm Switch will transmit Alarm Diag 4 notifications to the numbers located at cell positions 2SMS 6SMS Diagram 4 Default notification indicating the position of the Relay contacts Pcn ON Relay contacts closed Pcn OFF Relay contacts open S...

Страница 8: ...once a week 0 Notification not sent 18 AlarmNot 1 Alarm notification Option Type when Relay contact position Changes 0 Only SMS to 1sms 6sms 1 Call SMS SMS sent to1sms then callsplaced to all tel numbers followed by SMS transmittal to allremaining tel numbers 2sms 6sms 3 Only calls placed to 1sms 6sms 26 Pcn ON 1 Event Description whenRelay Contacts Closed Text up to 20 Latinalphabet characters e ...

Страница 9: ...lay Sensor Alarm Switch has entered Programing mode During the entire duration of the Programing mode the LED indicator will glow green In the event the GSM LED continues to flash quickly the SIM card is not registering on the GSM network and might be due to the SIM card being incorrectly or not installed blocked by a PIN code or the GSM network is inaccessible take steps in accordance with table ...

Страница 10: ...all is received the GSM Relay Sensor Alarm Switch will transmit an SMS containing the settings see diag 8 to the primary telephone number and will then enter Armed On Guard mode If you were unable to record all the necessary additional notification telephone numbers either re insert in the Protective Plastic Insert between the battery and contacts or remove the battery wait 2 two minutes and then ...

Страница 11: ... marks and spaces In order to change several parameters at once it is necessary to list the parameters separating them with a comma For example 2 1xxxxxxxxxx 18 3 27 Alarm 36 1 etc Note Characters are entered without quote marks and spaces 2 Access Programing mode in the GSM Relay Sensor Alarm Switch item 2 3 3 Send a previously prepared SMS message to the GSM Relay Sensor Alarm Switch telephone S...

Страница 12: ...cables Diag 7 Installation Size Specifications In order to install the GSM Relay Sensor Alarm Switch consecutively execute the following steps 1 Select a location to install the GSM Relay Sensor Alarm Switch 2 Mark up the selected installation location bearing in mind measurements and the location of mounting holes as located on the GSM Relay Sensor Alarm Switch base 3 Install the GSM Relay Sensor...

Страница 13: ...k is inaccessible 1 Verify the presence of a SIM card 2 Remove SIM card re install as shown in diag 7 3 Disable the SIM card PINcode feature by using a GSMTelephone see tel operatingmanual 4 a Re locate the GSM Relay Sensor Alarm Switch to a location with good access to a GSM Network signal in accordance with item 2 7 inthis user s manual b Change the mobile Network provider When verifying operati...

Страница 14: ...not in accordance with the instruction manual The warranty does not cover physical damage of any kind whatsoever nor does it cover damage caused by any attempt to tamper with or disassemble the product The warranty coverage does not extend to the batteries The warranty period commences on the day first purchased from the manufacturer or an authorized reseller as evidenced by a purchase receipt Wit...

Страница 15: ...17 ...

Отзывы: