Malfunction

Possible cause

Remedy

Frequent drive belt failure

Incorrect belt tension

Check belt tension and correct if necessary. See section 

5b

Motor pulley out of alignment

Check pulley alignment and correct if necessary

Pulley grooves worn

Replace transmission parts

Hostile environment (belts contaminated)

Replace belt, clean pulleys and protect blower from 

hostile environment

Incorrect belt fitted

Replace existing belt with Almeco approved belt

Incorrect belt installation method (Rolling 

belts onto pulleys)

Read manual (Section 5b) for correct installation and do 

not roll belts

Liquid entering blower inlet

Avoid any liquid entering blower

Incorrect starting ramp

The unit is designed to run CONTINUOUSLY. The start 

and stop must be progressive; if an inverter is used we 

recommend a 5 second ramp up time. If a star/ delta 

timer is used ensure there is no delay between switch-

ing from star to delta

Too many stop/ starts

Avoid high number of stop starts (max of 6 per hour) 

unless using a frequency inverter or a soft start. Sug-

gested minimum inverter setting = 30Hz

Electrical overloading

Exceeding rated CFM

Reduce “open area” of air delivery devices - i.e. slot 

width of Airknives

Blower not piped to system

Only run blower when connected to the operating 

system. Never run in isolation

Blower RPM too high

Reduce blower speed via inverter or change pulley size

Motor has winding or bearing damage

Contact Almeco immediately

Electrical supply problems

Ensure that supply voltages match with the motor rat-

ing plate details

Irregular/ excessive noise

Blockage in air delivery ducting

Check all ducting and air delivery devices for block-

ages/ damage. Replace as necessary

Leak in air delivery ducting

Check and replace damaged hose and clips.

Inlet silencer damaged (internally)

Replace main EP10 filter housing. See Section 5

Loose drive belt

Check belt tension and correct if necessary. See Section 

5b

Bolts loose on blower/ motor assembly

Regular maintenance and checking/ tightening all bolts

Motor mounts loose

Regular maintenance and checking/ tightening all 

mounts

Blower bearings worn

Contact Almeco immediately

Motor bearings worn

Contact Almeco immediately

Blower RPM too high

Reduce blower speed via inverter or change pulley size

Blower is receiving vibration from other 

equipment nearby

Isolate the blower using anti-vibration mounts

 

If you experience a problem and are in any doubt on the cause or possible remedial action required, please contact  

 

your local distributor.

Содержание ACI EP10A

Страница 1: ...www almeco eu DRYING SYSTEMS EP10A Compact blower Installation operation maintenance Instruction manual EP10A compact blower...

Страница 2: ...information 4 a Description and model identification b Equipment arrival 3 Key features and dimensions 5 a Key EP10A features b Key EP10AH features c Illustration further EP10A key features 4 Install...

Страница 3: ...of starts and stops if so then use a timer delay in the control to avoid frequent switching The EP10A blower needs to have airflow passing through it to ensure temperatures are not exceeded The use of...

Страница 4: ...or as a hot air version EP10AH where air temperatures of up to 365 F 185 C can be processed Almeco clearly labels each EP10A EP10AH blower unit on the back of the blower head as well as the motor cow...

Страница 5: ...er should be cleaned regularly and the main element replaced every six months Drive belt guard Poly V belt Motor pulley Motor IE3 Blowerhead EP10 A Filter Ref B3 003 039 B3 000 185 Pre lter B3 000 147...

Страница 6: ...www almeco eu Ref B3 003 037 Thermal cut Hot air Ref ACEP 250H 7 EP10A compact blower c Illustration furtherEP10AKeyFeatures d EP10AHeadOptions Electric Motor Standard Metric or NEMA Filter Assembly B...

Страница 7: ...mounting plate is provided to suit the large C face configuration NOTE Allow room for bracket movement during belt replacement Very low vibration levels of these units allow them to be bolted to any...

Страница 8: ...r If an inverter is not used use a suitable starter with overload protection star delta starter f Shaft rotation All units rotate counter clockwise when viewing the blower from the cooling fan of the...

Страница 9: ...tend the life of the mechanical components and ensure continued efficiency and longevity Removing filter element Step 1 Remove pre filter element by releasing the security nut and washer Use a 17mm AF...

Страница 10: ...f the unit is still not dry Re fitting filter elements Once the main filter element and the pre filter sock are thoroughly dried they can be re fitted to each other Refit the filter and its cover and...

Страница 11: ...2 nuts on the adjusting screw apply sufficient tension to raise the blower head back plate assembly into its approximate position and lightly tighten the M10 bolts to hold the assembly in place Tensio...

Страница 12: ...ith the poly vee pulleys Do not force the belt or roll the belt onto the pulleys Ensure the blower head is low enough to allow the belt to clear before attempting to fit Using the M12 nuts on the adju...

Страница 13: ...lter Maintenance Damaged hose lining Replace damaged hose Air leaks in system Check replace damaged hose and clips Drive belt slipping Worn Pulley Replace transmission parts Incorrect speed from contr...

Страница 14: ...cal overloading Exceeding rated CFM Reduce open area of air delivery devices i e slot width of Airknives Blower not piped to system Only run blower when connected to the operating system Never run in...

Страница 15: ...espective manufacturer s policy Motors and other items for which a national service network is in place should be sent directly to that manufacturer s representative for the most prompt service Almeco...

Отзывы: