TRIMMER – FUSE – RELAY   

 

P1

 WORKING TIME TRIMMER 

P2

 PAUSE TIME TRIMMER 

P3

 PEDESTRIAN TIME TRIMMER 

 

F1 

 FUSE 5X20 T0,8A  

on 18Vac  

protection : electronic supply and exit 24Vdc. 

F2 

 FUSE 5X20 F2A 

on 230Vac 

protection : transformer, contacts and blinker of 230Vca. 

 

RL1

 LIGHT OF COURTESY RELAY (exit 24Vdc) 

RL2

 BLINKER RELAY OF 24Vac 

RL3

 OPEN RELAY 

RL4

 CLOSE RELAY  

RL5

  SECURITY RELAY and BLINKER RELAY 230V  

DECLARATION OF CONFORMITY 

(according to ISO/IEC Guide 22 and EN 45014) 

 

Manufacturer’s Name :  

 

ALLTRONIC s.n.c. 

Manufacturer’s Address : 

 

Via Torino. 84—12041 Bene Vagienna (Cn) Italy 

 

 

DECLARES THAT THE FOLLOWING PRODUCT

 

 

Product Name :  

Gate Opener for Rapid Door

 

Model : 

 

Micro7 

 

CONFORMS TO THE FOLLOWING EMC SPECIFICATIONS BASED ON SAMPLE TESTING: 

 
 

 

 

 

EN 55011 

 

 

 

 

EN 60335-1 

 

 

 

 

EN 55014-1   

 

 

 

EN 60204-1 

 

 

 

 

EN 55014-2   

 

 

 

EN 12453 

 

 

 

 

EN 61000-3-2 

 

 

 

EN 61000-6-1 

 

 

 

 

EN 61000-3-3 

 

 

 

EN 61000-6-3 + A11 

 

The product has been tested in the typical installation configuration and with peripherals which conform to EMC Directive. 

 

I the undersigned declare that the product herewith complies with the protection requirements of the 

EMC Directive 89/336/

EEC

, the

 73/23/CEE Low Tension Directive 

and also the  

Directive

 

89/392/CEE 

(Electric Equipment Security of the Devi-

ces). 

 

Bene Vagienna, 30/10/2006  

 

 

 

 

 

 

     Allodi Francesco 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proprietario 

Gate-Opener Control Type Micro 7 Threephase 400V 

 

For rolling (fast) door   

Содержание Micro7

Страница 1: ...ARES THAT THE FOLLOWING PRODUCT Product Name Gate Opener for Rapid Door Model Micro7 CONFORMS TO THE FOLLOWING EMC SPECIFICATIONS BASED ON SAMPLE TESTING EN 55011 EN 60335 1 EN 55014 1 EN 60204 1 EN 5...

Страница 2: ...TERMINAL BLOCK M6 22 23 Input 24Vac external supply with fuse 24 25 Input 18Vac 4 POLE TERMINAL BLOCK M7 26 27 Input Arial RX Radio 27 Hold 28 29 Exit from RX Radio Channel 2 6 POLE TERM BLOCK M8 30...

Страница 3: ...THE CYCLE il pulsante di blocco 5 e 6 di M1 lo spegne OFF THE BLINKER FIRST BLINK 4 SEC BEFORE CLOSING the button of block 5 and 6 of M1 switches it off DIP 6 ON AUTO TEST FUNCTION DW24B ACTIVATED OF...

Страница 4: ...NING With DIP7 on ON B LOW PHOTOCELL PHOTOCELL BLOCKS IN CLOSING With DIP6 on ON DW24B edges DW24B BLOCKS IN CLOSING With DIP8 on OFF A HIGH PHOTOCELL PHOTOCELL NOT CONNECTED OR DISACTIVATED With DIP7...

Страница 5: ...versal time 0 5 sec Dip 4 OFF Dip 3 OFF reversal time 1 sec set of factor Dip 4 ON Dip 3 ON reversal time 2 sec Dip 4 OFF Dip 3 ON reversal time 4 sec Dip 4 ON SHUNTS SET W3 W4 W5 W6 W7 For predisposi...

Страница 6: ...working time combination P1 The control works with normally closed End run N C With the gate opened the pause timer It can be bypassed pressing the button of close after the deter minated time P2 will...

Страница 7: ...hen the motor opens The motor does not open the door com pletely Control close at once Control reverse the movement bru squely Photocell stops on Open Control does not open Control does not open Times...

Страница 8: ...he control have a load of 9 Amp And they must be relating to their load periodically checked It is advisable to overhaul the relay contacts every 4 years but always according to the following condi ti...