background image

LEDS VISUALIZATION 

 

DL1 

(yellow  led) 

LIGHT (On) : DW24B in warning (contact Open)

 

 
DL2

 (green led)

   

SWITCHED ON   : power supply insert 

 

 

 

 

SWITCHED OFF : lack of supply 

 

DL3

 ( red led )

   

SWITCHED ON : pressed OPEN order

 

 

 

 

 

 

 

It remains lighted only during the time while it is pressed

 

 

DL4 

( red led )

   

SWITCHED ON : presses CLOSE order

 

 

 

 

 

 

 

It remains lighted only during the time while it is pressed

 

 

DL5 

( red led )

   

SWITCHED ON : pressed AP/CH order (Dynamic) 

 

DL6

 ( red led )

   

SWITCHED ON : pressed PEDESTRIAN order 

 

DL7 

(yellow led ) 

SWITCHED ON   : semi automatic cycle activated 

 

 

 

 

SWITCHED OFF : automatic cycle activated 

 

DL8

 ( yellow led )

 

SWITCHED ON : present LOW PHOTOCELL (Open contact) 

 

DL9

 ( yellow led )

 

SWITCHED ON : present HIGH PHOTOCELL (Open contact) 

 

DL10

 ( yellow led )

 

SWITCHED ON : present button of BLOCK (Open contact) 

 

DL11

 ( red led )

   

SWITCHED ON : present END-RUN OF OPEN (Open contact) 

 
DL12

 (red led )   

SWITCHED ON : present END-RUN OF CLOSE (Open contact) 

 
 

Functionnement 

 

Automatic Cycle: 

Pressing N.O. button of Open the motor will begin to move for the time determinated 

by the “End-run/working time” combination (P1).  
The control works with normally closed End-run (N.C.). 
With the gate opened the pause timer (It can be bypassed pressing the button of close) , after the deter-
minated time (P2), will close the door. If during the pause time an object or a person crosses the photo-
cell, it resets the the pause time which will start again from the beginning. We get same function, always 
during the pause time, giving an opening impulse. 
The contact of 

Low and Hight Photocell 

(N.C.) is activated only during the reclosing phase, it opens 

again the door if  there is an obstacle.  
A possible temporary Block of the control can be obtained by acting on the block button (N.C.), in this 
case the motor will stop until the open-close button will be pressed again giving movement to the gate in 
the desired direction. 

 
Pedestrian Function 

: N.A. enter contact which operates the opening door for the time determinated by 

the P3 trimmer.  
During the reclosing phase the photocell or an impulse of Open will open the door completely. 

 
Semiautomatic Cycle 

(pass-pass): 

All the functions are the same of the automatic cycle except the pause time that is not inserted, therefore 
to reclose you should press the close button once again. 

Содержание Micro7

Страница 1: ...ARES THAT THE FOLLOWING PRODUCT Product Name Gate Opener for Rapid Door Model Micro7 CONFORMS TO THE FOLLOWING EMC SPECIFICATIONS BASED ON SAMPLE TESTING EN 55011 EN 60335 1 EN 55014 1 EN 60204 1 EN 5...

Страница 2: ...TERMINAL BLOCK M6 22 23 Input 24Vac external supply with fuse 24 25 Input 18Vac 4 POLE TERMINAL BLOCK M7 26 27 Input Arial RX Radio 27 Hold 28 29 Exit from RX Radio Channel 2 6 POLE TERM BLOCK M8 30...

Страница 3: ...THE CYCLE il pulsante di blocco 5 e 6 di M1 lo spegne OFF THE BLINKER FIRST BLINK 4 SEC BEFORE CLOSING the button of block 5 and 6 of M1 switches it off DIP 6 ON AUTO TEST FUNCTION DW24B ACTIVATED OF...

Страница 4: ...NING With DIP7 on ON B LOW PHOTOCELL PHOTOCELL BLOCKS IN CLOSING With DIP6 on ON DW24B edges DW24B BLOCKS IN CLOSING With DIP8 on OFF A HIGH PHOTOCELL PHOTOCELL NOT CONNECTED OR DISACTIVATED With DIP7...

Страница 5: ...versal time 0 5 sec Dip 4 OFF Dip 3 OFF reversal time 1 sec set of factor Dip 4 ON Dip 3 ON reversal time 2 sec Dip 4 OFF Dip 3 ON reversal time 4 sec Dip 4 ON SHUNTS SET W3 W4 W5 W6 W7 For predisposi...

Страница 6: ...working time combination P1 The control works with normally closed End run N C With the gate opened the pause timer It can be bypassed pressing the button of close after the deter minated time P2 will...

Страница 7: ...hen the motor opens The motor does not open the door com pletely Control close at once Control reverse the movement bru squely Photocell stops on Open Control does not open Control does not open Times...

Страница 8: ...he control have a load of 9 Amp And they must be relating to their load periodically checked It is advisable to overhaul the relay contacts every 4 years but always according to the following condi ti...

Отзывы: