ITA
ENG
FRA
ESP
DEU
POR
6-1624050 rev.12 14/11/2012 Pag 7 di 9
Mark the points (C and D) in which the fixing clamps (on the part of the
architrave) will be fixed to the ceiling.
By fixing the clamps at the ceiling, make sure that the guide is linked up
with the clamp on the architrave and that it is on level.
A
B
C
D
figure 25
3.4.3 Installation device of unlock
If the door is without a second entry, it is necessary to provide to the in-
stallation of the emergency unlock system.
In this way the door can be also moved without the intervention of the au-
tomation. Make the wire of steel pass (from the part of the head without
stop) through the eye present on the unblocking lever (fig.26).
figure 26
figure 27
Insert the wire inside the sheath (fig.27) and make it slide through her
completely.
It is advisable lubricate the wire in the way to make easy the sliding inside
the sheath.
Insert the head of the free cable inside to the stop provided on the clamp
fixed to the door (fig.28)
figure 28
Insert the supplied knob and stop it by using the clamp (fig.29).
figure 29
3.4.4 Mounting of the courtesy light
1.
Cut off the power supply to the system.
2.
Insert a lamp BAS9s, max 20W.
3.
Fix to join the lamp by rotating it in clockwise sense.
4.
Drive the screw of the carter of the gear motor.
The courtesy light remains turned on 1,30 minutes from the last order given