7
en
English
16a
V
725 Relay 2
18. Loosen the screw on AC post 2 of 725 light relay 2 and
connect the fork terminal on the wire (
V
, Figure 16a)
that is leading from either light switch 3 or 4 into the
post. Tighten down the screw onto the fork terminal.
19. On Zettler light relay 2 disconnect the existing 16 AWG
black wire (
W
, Figure 16a-b) from the DC ground
spade. This wire should be leading from the divider
panel of the component block. On Zettler relay 1
disconnect the 16 AWG black wire from the same
spade.
20.
Cut off and discard the female spade terminal from
the wire that was connected to the Zettler relay. Strip
off the appropriate amount of wire insulation and install
wire (
X
, Figure 17) into a 3 pin lever lock (
Y
, Figure 17,
Ref. 10) from the kit contents.
Zettler Relay
Disconnection Detail
16b
W
Zettler Relay 2
W
Zettler Relay 2
17
X
Y
21. From the kit contents, locate and select the black 16
AWG wire (
Z
, Figure 18, Ref. 2). Cut the black 16
AWG wire in half, and strip the ends of the cut wires.
On each of the cut wires crimp a blue fork terminal
(
AA
, Figure 18, Ref. 8) on one of the ends.
18
Z
AA
22. Install the fork terminal end of each black wire (
BB
,
Figure 19a-b) on DC post 1 of 725 light relay 1 and 2.
Then, install the bare wire ends of the two black wires
into the open ports of the 3 port lever lock (
CC
, Figure
19a-b) that was installed in Step 20.