11. Loosen the screw on AC post 1 of 725 light relay 2 and
connect the fork terminal on the wire (
K
, Figure 9a-b)
leading from either Distribution block 1 or 2 into the
post. Tighten down the screw onto the fork terminal.
5
en
English
8
Distribution Block 1
Distribution Block 2
J
9a
K
725 Relay
Connection Detail
9b
K
725 Relay 2
725 Relay 2
12. If replacing Zettler relay 2, locate the 12 AWG wire
(
L
, Figure 10a-b) that is leading from the relay to
light switches 2 and 4. If working from Zettler relay 1
locate wire from light switches 1 and 3. Remove the
two screws (
M
, Figure 10a), the 12 AWG wire, and
buss bar (
N
, Figure 10a) from the top of the switches.
Discard the buss bar, and set one of the screws aside
as it will be used in Step 17. Depending on Zettler
relay, re-install the wire and screw onto light switch 1
or 2.
Light Switches Detail
10a
L
Light Switch 2
Light Switch
Connection Detail
10b
Light Switch 2
Light Switch 4
Light Switch 1
Light Switch 3
L
N
M