13. On Zettler light relay 2, disconnect the 12 AWG wire
(
O
, Figure 11) from the AC light switch spade, and this
wire was just reconfigured on the light switch 2. On
Zettler relay 1, disconnect the wire leading from light
switch 1 from the same spade.
14.
Cut off and discard the female spade terminal from the
wire that was connected to the Zettler relay. Strip off
the appropriate amount of wire insulation and crimp
a yellow fork terminal (
P
, Figure 12, Ref. 7) onto the
wire.
15. Loosen the screw on AC post 1 of 725 light relay 1 and
connect the new fork terminal on the wire (
Q
, Figure
6a-b) removed from either Zettler relay 1 or 2 into the
post. Tighten down the screw onto the fork terminal.
Zettler Relay
Disconnection Detail
11
O
Zettler Relay 2
12
P
6
www.allmand.com
13
725 Relay 1
Q
16. Take the cut 10 AWG wire (
R
, Figure 14) that was set
aside in Step 9 and crimp a yellow fork terminal (
S
,
Figure 14, Ref. 7) on one of the ends. On the other
end, crimp on the terminal ring (
T
, Figure 14, Ref. 6).
14
T
S
R
17. If working from Zettler relay 2, install the terminal ring
end of the new assembled 10 AWG wire (
U
, Figure
15a-b) onto the top of light switch 4 by using the screw
that was removed in Step 12. If working from Zettler
relay 1, install wire onto light switch 3 (Not Shown).
Make sure screw is tightened down on the ring
terminal.
15a
U
Light Switch 2
Light Switch 4
Light Switch 1
Light Switch 3
Light Switch
Connection Detail
15b
Light Switch 4
U
Not for
Reproduction