508151-01
Issue 2104
Page 6 of 72
Unit Components
A96DS2V unit components are shown in Figure 1. The gas
valve, combustion air inducer and burners can be accessed
by removing the access panel. Electrical components are
in the control box (Figure 2) found in the blower section.
Electrostatic discharge can affect
electronic
components.
Take
precautions to neutralize electrostatic
charge by touching your hand and
tools to metal prior to handling the
control.
CAUTION
Control Box
Control Transformer (T1)
A transformer located in the control box provides power
to the low voltage section of the unit. Transformers on all
models are rated 40VA with a 120V primary and a 24V
secondary.
Transformer
Integrated Control
Interlock Switch
Circuit Breaker
Figure 2. Control Box
Door Interlock Switch (S51)
A door interlock switch rated 14A at 125VAC is wired in
series with line voltage. When the inner blower access
panel is removed the unit will shut down.
Circuit Breaker (CB8)
A 24V circuit breaker is also located in the control box. The
switch provides overcurrent protection to the transformer
(T1). The breaker is rated 3A at 32V. If the current exceeds
this limit the breaker will trip and all unit operation will
shutdown. The breaker can be manually reset by pressing
the button on the face. See Figure 3.
PRESS TO RESET
Figure 3.
Circuit Breaker CB8
Shock hazard.
Disconnect power before servicing. Integrated control
is not field repairable. If control is inoperable, simply
replace entire control.
Can cause injury or death. Unsafe operation will result
if repair is attempted.
WARNING
Integrated Control (A92)
Units are equipped with a variable capacity integrated
control. This control is used with the Comfort Sync
®
thermostat as part of a communicating comfort system.
The control can also operate with a non-communicating
conventional single or two-stage thermostat. The system
consists of an ignition / blower control (Figure 4 and Figure
5) with control pin designations (Table 1 through Table 3)
and an ignitor. The control and ignitor work in combination
to ensure furnace ignition and ignitor durability. The
control provides gas ignition, safety checks and indoor
blower control with two-stage gas heating. The furnace
combustion air inducer, gas valve and indoor blower are
controlled in response to various system inputs such as
thermostat signal, pressure and limit switch signal and
flame signal. The control features a seven-segment LED
display, indicating furnace status (including indoor blower)
and error codes. The LED flashes in single digits. For
example, using Table 5 under CODE, an “E” followed by
“2” followed by “5” followed by “0”, the limit switch circuit
is open. The control also has two unpowered (dry) 1/4”
contacts for a humidifier and a 120 volt accessory terminal.
Both rated at (1) one amp each.