Allied 2HP13 Скачать руководство пользователя страница 2

506162-02

Issue  0847

      Page  2  of   14

Safety Precautions

Follow all safety codes.  W ear safety glasses and work

gloves.  Use quenching cloth for brazing operations.  Have
fire extinguisher available.  Read these instructions
thoroughly and follow all warning or cautions attached to
the unit.

1.

Always wear proper personal protection equipm ent.

2.

Always disconnect electrical power before rem oving
panel or servicing equipm ent.

3.

Keep hands and clothing away from  m oving parts.

4.

Handle refrigerant with caution, refer to proper MSDS
from  refrigerant supplier.

5.

Use care when lifting, avoid contact with sharp edges.

UNIT LOCATION & INSTALLATION 

NOTE:

In som e cases noise in the living area has been
traced to gas pulsations from  im proper installation
of equipm ent.

 1. Locate unit away form  windows, patios, decks, etc.

where unit operation sounds m ay disturb custom er.

 2. Ensure that vapor and liquid tube diam eters are

appropriate to capacity of unit.

 3. Run refrigerant tubes as directly as possible by

avoiding unnecessary turns and bends.

 4. Leave som e slack between structure and unit to

absorb vibration.

 5. W hen passing refrigerant tubes through the wall, seal

opening with RTV or other silicon-based caulk.

 6. Avoid direct tubing contact with water pipes, duct  work,

floor joists, wall studs, floors, walls, and any structure.

 7. Do not suspend refrigerant tubing from  joists and  studs

with a rigid wire or strap which com es in direct contact
with tubing.

 8. Ensure that tubing insulation is pliable and com pletely

surrounds vapor tube.

W hen outdoor unit is connected to factory-approved

indoor unit, outdoor unit contains system  refrigerant charge
for operation with indoor unit of the sam e size when
connected by 15 ft. of field-supplied tubing.  For proper unit
operation, check refrigerant charge using charging
inform ation located on control box cover.

IM PORTANT:

Maxim um  liquid-line size is 3/8 in. O.D. for
all residential applications including long
lines.

Outdoor Section

Zoning ordinances m ay govern the m inim um  distance

the condensing unit can be installed from  the property line.

Install on a Solid, Level M ounting Pad

The outdoor section is to be installed on a solid

foundation.  This foundation should extend a m inim um  of
2" (inches) beyond the sides of the outdoor section.  To
reduce the possibility of noise transm ission, the foundation
slab should NO T be in contact with or be an integral part of
the building foundation.

This product and/or the indoor unit that is m atched
with m ay contain fiberglass wool.

Disturbing the insulation during installation,
m aintenance, or repair will expose you to fiberglass
wool dust.  (Fiberglass wool is known to the State of
California to cause cancer.)

Fiberglass wool m ay also cause respiratory, skin,
and eye irritation.

To reduce exposure to this substance or for further
inform ation, consult m aterial safety data sheets
available from  your distributor.

NOTE TO INSTALLING DEALER

These instructions and warranty are to be given
to the owner or prominently displayed near the
indoor air handler unit.

Before installing, m odifying, or servicing system ,
m ain electrical disconnect switch m ust be in the OFF
position. There m ay be m ore than 1 disconnect
switch.  Lock out and tag switch with a suitable
warning label.  Electrical shock can cause personal
injury or death.

Содержание 2HP13

Страница 1: ...l Code Part 1 CSA C22 1 2HP13 14 4HP13 SPLIT SYSTEM HEAT PUMP INSTALLATION START UP INSTRUCTIONS HOMEOWNERS INFORMATION MANUAL TABLE OF CONTENTS These units are designed for use in residential and light commercial type buildings Heat Pumps may only be installed with indoor combinations listed in the Air Conditioning and Refrigeration Institute ARI Directory of Certified Products Inspect the unit f...

Страница 2: ...nnected to factory approved indoor unit outdoor unit contains system refrigerant charge for operation with indoor unit of the same size when connected by 15 ft of field supplied tubing For proper unit operation check refrigerant charge using charging information located on control box cover IMPORTANT Maximum liquid line size is 3 8 in O D for all residential applications including long lines Outdo...

Страница 3: ...rant line lengths DO NOT LOCATE THE UNIT On brick concrete blocks or unstable surfaces Near clothes dryer exhaust vents Near sleeping area or near windows Under eaves where water snow or ice can fall directly on the unit with clearance less than 2 ft from a second unit with clearance less than 4 ft on top of unit Operating Ambient The minimum outdoor operating ambient in cooling mode is 55 F and t...

Страница 4: ...th water using a wet rag Leave rag on fitting body and re wet with water to help cool area Leak Check Refrigeration lines and indoor coil must be checked for leaks after brazing and before evacuation The recommended procedure is to apply a trace amount of vapor refrigerant approximately two ounces or 3 psig into the line set and indoor coil then pressurize with 150 psig of dry nitrogen Use a refri...

Страница 5: ... at the line side of the contactor in the control box of the outdoor unit Follow the appropriate wiring diagram attached to inside of the access panel Proper circuit protection recommendations are indicated on Unit Rating Plate Time delay fuses are required to prevent blowing due to starting current the current in rush when equipment starts is referred to as the Locked Rotor Amps or LRA A fuse of ...

Страница 6: ...or line sets shorter than 15 feet in length remove charge For line sets longer than 15 feet add charge Oil charge is sufficient for all line lengths Before final adjustment is made to the refrigerant charge it is imperative that proper indoor airflow be established Airflow will be higher across a dry coil versus a wet coil Blower charts are calculated with a dry or wet coil basis Recommended airfl...

Страница 7: ...ously Filter Drier The outdoor unit is equipped with a bi flow filter drier If replacement is necessary order new dryer according to the service parts manual Emergency Heat Function Room Thermostat An emergency heat function is designed into some room thermostats This feature is applicable when isolation of outdoor unit is required or when auxiliary electric heat is staged by outdoor thermostats W...

Страница 8: ... seconds going in and out of the defrost mode when the compressor delay jumper is removed NOTE The 30 second off cycle is not functional when jumpering the TEST pins Time Delay The timed off delay is 5 minutes long The delay help to protect the compressor from short cycling in case the power to the unit is interrupted or a pressure switch opens The delay is bypassed by placing the timer select jum...

Страница 9: ...506162 02 Issue 0847 Page 9 of 14 H P SINGLE PHASE WIRING DIAGRAM ...

Страница 10: ...506162 02 Issue 0847 Page 10 of 14 H P 3 PHASE WIRING DIAGRAM ...

Страница 11: ... manufacturers The information below is typical for most thermostats Ask your dealer for specific information regarding the model of thermostat installed Temperature Setting Levers Most heat pump thermostats have 2 temperature selector levers one for heating and one for cooling Set the levers or dials to the desired temperature set points for both heating and cooling Avoid frequent temperature adj...

Страница 12: ...s dryers and fall off from trees can be drawn into coils by movement of the air Clogged condenser coils will lower the efficiency of your unit and could cause damage to the condenser Periodically debris should be brushed from the condenser coils Use a soft bristle brush with light pressure only DO NOT damage or bend condenser coil fins Damaged or bent fins may affect unit operation Painted Surface...

Страница 13: ...lete model and serial number b proof of required periodic maintenance installation date and location c an accurate description of the problem W ARRANTY LIMITATIONS 1 This warranty is void if the covered equipment is removed from the original installation site 2 This warranty does not cover damage or defect resulting from a flood wind fire lightning mold or installation and operation in a corrosive...

Страница 14: ...506162 02 Issue 0847 Page 14 of 14 NOTES ...

Отзывы: