Installation and hardware GigE
20
Goldeye G/CL Technical Manual V4.1.1
Mounting the camera
You can attach the camera to a base in two ways:
1. To attach the camera to any horizontal or vertical base, four mounting threads
M4 x 6 mm are located on each side of the camera, except for the back side.
-
Refer to the drawings in chapter
for the
exact distances between the mounting threads.
-
To avoid damaging the camera housing, we recommend using bolts with an
effective length of 4 to 6 mm and apply a maximum torque of 2.0 Nm to
each bolt.
2. To attach the camera to the common mounting plate of tripods used in
photography, a 1/4 - 20 UNC mounting thread is located on the camera
bottom.