Camera interfaces
Goldeye Technical Manual
V2.2.0
40
Exposure output (pin 12, 13)
The exposure output indicates the active exposure time of the sensor in the
image-on-demand operation. At the end of the exposure this output stays
active for one line duration (32 μs Goldeye xy-008 or 63.4 μs Goldeye xy-032)
longer than the real exposure.
After end of exposure the 256 (Goldeye xy-008) or 508 (Goldeye xy-032) lines
of the sensor are read out to the digital output.
Line-sync output (pin 14)
The line-sync output (active low) supplies approx. 900 mV at a termination with
75 ohms.
Figure 12: Exposure output diagram
Caution
The current which flows through the optocoupler should not
exceed 20 mA (at 12 V R
v
600
).
Figure 13: Line-sync output diagram
Goldeye xy-008
Goldeye xy-032
Содержание Goldeye CL-008 SWIR
Страница 35: ...Start up Goldeye Technical Manual V2 2 0 35 Note For more information see Chapter Image processing on page 54...
Страница 50: ...Data interface Goldeye Technical Manual V2 2 0 50 Figure 17 Timing diagram Goldeye xy 008 320x160...
Страница 51: ...Data interface Goldeye Technical Manual V2 2 0 51 Figure 18 Timing diagram Goldeye xy 032...