Configuration of the camera
MARLIN Technical Manual
V2.4.0
229
Advanced register: trigger counter
The
trigger counter
feature is controlled by the following advanced feature
register:
Having this feature enabled, the current
trigger counter
value (external trig-
ger seen by hardware) will be inserted as a 32-bit integer value into any cap-
tured image.
Setting the
Reset
flag to 1 resets the
trigger counter
to 0 – the Reset flag
is self-cleared.
The
ON_OFF
and
LinePos
fields are simply mirrors of the time stamp feature.
Settings of these fields are applied to all image stamp features.
Additionally there is a register for direct read out of the
trigger counter
value.
Register
Name
Field
Bit
Description
0xF1000620 TRGCNT_STAMP
Presence_Inq
[0]
Indicates presence of this
feature (read only)
Reset
[1]
Reset trigger counter
---
[2..5]
Reserved
ON_OFF
[6]
SIS (time stamp) on/off
---
[7]
Reserved
---
[8..15]
Reserved
LinePos
[16..31]
Line position of SIS
(time stamp)
0xF1000624 TRGCNT
[0..31]
Trigger counter
Table 127: Advanced register:
Trigger counter
Note
L
The 4 bytes of the
trigger counter
value will be inserted as
the
9th to 12th byte of a line
.
Содержание AVT Marlin
Страница 43: ...Camera dimensions MARLIN Technical Manual V2 4 0 43 Tripod adapter Figure 17 Tripod dimensions...
Страница 63: ...Camera interfaces MARLIN Technical Manual V2 4 0 63 Figure 30 Y8 and Y16 format Source IIDC V1 3...
Страница 64: ...Camera interfaces MARLIN Technical Manual V2 4 0 64 Figure 31 Data structure Source IIDC V1 3...
Страница 87: ...Description of the data path MARLIN Technical Manual V2 4 0 87 Figure 44 Generation of shading image...