Configuration of the camera
MARLIN Technical Manual
V2.4.0
200
040h
PACKET_PARA_INQ
See note
044h
BYTE_PER_PACKET
According to IIDC V1.3
Note
L
•
For all modes in Format_7,
ErrorFlag_1
and
ErrorFlag_2
are refreshed on each access to the
Format_7 register.
•
Contrary to IIDC V1.3, registers relevant to Format_7
are refreshed on each access. The
Setting_1
bit is
automatically cleared after each access.
•
When
ErrorFlag_1
or
ErrorFlag_2
are set and Format_7
is configured, no image capture is started.
•
Contrary to IIDC v.1.3, COLOR_CODING_ID is set to a
default value after an INITIALIZE or
reset
.
•
Contrary to IIDC V1.3, the
UnitBytePerPacket
field is
already filled in with a fixed value in the
PACKET_PARA_INQ register.
Offset
Name
Notes
Table 96: Format_7 control and status register