Configuration of the camera
MARLIN Technical Manual
V2.4.0
213
Look-up tables (LUT)
Load the look-up tables to be used into the camera and choose the look-up
table number via the
LutNo
field. Now you can activate the chosen LUT via
the LUT_CTRL register.
The LUT_INFO register indicates how many LUTs the camera can store and
shows the maximum size of the individual LUTs.
The possible values for
LutNo
are 0..n-1, whereas n can be determined by
reading the field
NumOfLuts
of the LUT_INFO register.
Register
Name
Field
Bit
Description
0xF1000240
LUT_CTRL
Presence_Inq
[0]
Indicates presence of this
feature (read only)
---
[1..5]
Reserved
ON_OFF
[6]
Enable/Disable this feature
---
[7..25]
Reserved
LutNo
[26..31] Use look-up table with
LutNo
number
0xF1000244
LUT_MEM_CTRL
Presence_Inq
[0]
Indicates presence of this
feature (read only)
---
[1..4]
Reserved
EnableMemWR
[5]
Enable write access
---
[6..7]
Reserved
AccessLutNo
[8..15]
Reserved
AddrOffset
[16..31] byte
0xF1000248
LUT_INFO
Presence_Inq
[0]
Indicates presence of this
feature (read only)
---
[1..7]
Reserved
NumOfLuts
[8..15]
Maximum number of look-up
tables
MaxLutSize
[16..31] Maximum look-up table size
(bytes)
Table 107: Advanced register:
LUT
Содержание AVT Marlin
Страница 43: ...Camera dimensions MARLIN Technical Manual V2 4 0 43 Tripod adapter Figure 17 Tripod dimensions...
Страница 63: ...Camera interfaces MARLIN Technical Manual V2 4 0 63 Figure 30 Y8 and Y16 format Source IIDC V1 3...
Страница 64: ...Camera interfaces MARLIN Technical Manual V2 4 0 64 Figure 31 Data structure Source IIDC V1 3...
Страница 87: ...Description of the data path MARLIN Technical Manual V2 4 0 87 Figure 44 Generation of shading image...