Problem
The switch’s time is incorrect, even though it assigns the correct time to
devices on the LAN.
Solution
The UTC offset is probably incorrect, or needs to be adjusted for the beginning
or end of summer time. To correct this, select Configuration > System > Time
and enter the correct offset.
Loading Software
Problem
You have attempted to load a new release file onto the switch, but the load
has failed and you cannot access the switch through the GUI.
Solution
1.
Access the switch’s CLI (see “
Connecting a Terminal or PC
” on page 14).
If the switch has been switched off or has rebooted since you attempted to
load the release file, it will boot up with the default installation. This
contains the commands you require to load a file.
Log into the switch using the manager account and password.
2.
Download the release file to the switch. See “Example: Upgrade to a New
Software Release Using TFTP” on page 59 for an example.