Electrical Requirements
67
70458301ENR6
24 kW 035 Series Electric Models
Table 16
27 kW 055 Series Electric Models
Table 17
Serial Plate Voltage
Terminal Block
Connections Required
Serial Plate Amps
Recommended Circuit
Nonreversing
Reversing
Breaker Rating
Wire Size
AWG (mm
2
)
208V/60Hz/1ph
L1, L2, Neutral, and ground
122
N/A
175A – 2 pole
2/0 (70)
240V/60Hz/1ph
L1, L2, Neutral, and ground
107
N/A
150A – 2 pole
1/0 (50)
200V/60Hz/1ph
L1, Neutral, and ground
122
N/A
175A – 1 pole
2/0 (70)
200V/50Hz/1ph
L1, Neutral, and ground
119
N/A
150A – 1 pole
1/0 (50)
230-240V/50Hz/1ph
L1, Neutral, and ground
108
N/A
150A – 1 pole
1/0 (50)
200-208V/60Hz/3ph
L1, L2, L3, and ground
71
71
90A* – 3 pole
3 (26.7)
200V/50Hz/3ph
L1, L2, L3, and ground
65
65
90A* – 3 pole
3 (26.7)
230-240V/50Hz/3ph
L1, L2, L3, and ground
62
N/A
80A* – 3 pole
4 (25)
240V/60Hz/3ph
L1, L2, L3, and ground
62
62
80A* – 3 pole
4 (25)
380V/50 or 60Hz/3ph
L1, L2, L3, and ground
38
38
50A* – 3 pole
6 (16)
400-415V/50Hz/3ph
L1, L2, L3, and ground
35
35
45A* – 3 pole
8 (10)
440V/60Hz/3ph
L1, L2, L3, and ground
33
N/A
45A* – 3 pole
8 (10)
460-480V/60Hz/3ph
L1, L2, L3, and ground
31
31
40A* – 3 pole
8 (10)
*
3 Phase machines should not have fuses, breakers only.
N/A = Not Applicable
Serial Plate Voltage
Terminal Block
Connections Required
Serial Plate Amps
Recommended Circuit
Nonreversing
Reversing
Breaker Rating
Wire Size
AWG (mm
2
)
208V/60Hz/1ph
L1, L2, Neutral, and ground
129
N/A
175A – 2 pole
2/0 (70)
240V/60Hz/1ph
L1, L2, Neutral, and ground
115
N/A
150A – 2 pole
1/0 (50)
200V/60Hz/1ph
L1, Neutral, and ground
122
N/A
175A – 1 pole
2/0 (70)
200V/50Hz/1ph
L1, Neutral, and ground
131
N/A
175A – 1 pole
2/0 (70)
230-240V/50Hz/1ph
L1, Neutral, and ground
119
N/A
150A – 1 pole
1/0 (50)
200-208V/60Hz/3ph
L1, L2, L3, and ground
79
79
100A* – 3 pole
3 (26.7)
240V/60Hz/3ph
L1, L2, L3, and ground
65
65
80A* – 3 pole
4 (25)
380V/50Hz/3ph
L1, L2, L3, and ground
43
43
60A* – 3 pole
8 (10)
400-415V/50Hz/3ph
L1, L2, L3, and ground
38
38
50A* – 3 pole
8 (10)
*
3 Phase machines should not have fuses, breakers only.
N/A = Not Applicable