© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Electrical Requirements
70458301ENR6
60
Conversion Instructions
If serial plate voltage is:
Tumble Dryer can be converted to the following voltages:
120 Volt/60 Hertz/
1 Phase
2W&G
(All models except T45)
208-240 Volt/60 Hertz/1 Phase Models:
3W&G
1. Prior to connecting service, locate the red or black with red stripe wire which
runs between terminal block and the fan motor relay or contactor.
Refer to figure below.
2. Disconnect the red or black with red stripe wire from L1 of the terminal block
and connect to L2 of the terminal block.
3. Sign and date conversion sticker located on back of tumble dryer.
4. Follow the instructions covered in
Connecting Electrical Service
section.
NOTE: Motors operate on 120 Volt power regardless of input voltage
configuration.
240 Volt/60 Hertz/
3 Phase
3W&G
200-208 Volt/60 Hertz/3 Phase Models:
3W&G
1. Prior to connecting electric service, locate transformer configuration jumper
in junction box area.
2. Remove the 240 Volt jumper and replace it with the 208 Volt jumper located
in the literature packet in cylinder.
3. Sign and date conversion sticker located on back of tumble dryer.
4. Follow the instructions covered in
Connecting Electrical Service
section.
208 or 240 V~
LOCATION
(AS CONVERTED)
120 V~ LOCATION
(AS RECEIVED)
RED OR BLK
WITH RED
STRIPE
POWER DISTRIBUTION BLOCK
TO FAN MOTOR
RELAY OR
CONTACTOR
208 OR
240 V-
120 V-
120 V-
L1
N
L2