Electrical Requirements
70458301ENR6
64
055 Series Gas Models
T30 Series Gas and Steam Models (Total Machine)
Serial Plate Voltage
Terminal Block
Connections Required
Serial Plate Amps
Recommended Circuit
Nonreversing
Reversing
Breaker Rating
Wire Size
AWG (mm
2
)
120V/60Hz/1ph
L1, Neutral, and ground
9.2
N/A
15A – 1 pole
14 (2.5)
208-240V/60Hz/1ph
L1, L2, Neutral, and ground
6.5
N/A
10A – 2 pole
14 (2.5)
100V/60Hz/1ph
L1, Neutral, and ground
9.8
N/A
15A – 1 pole
14 (2.5)
100V/50Hz/1ph
L1, Neutral, and ground
10
N/A
15A – 1 pole
14 (2.5)
200V/50Hz/1ph
L1, Neutral, and ground
6.2
N/A
15A – 1 pole
14 (2.5)
230-240V/50Hz/1ph
L1, Neutral, and ground
5.5
N/A
10A – 1 pole
14 (2.5)
200-208V/60Hz/3ph
L1, L2, L3, and ground
4.0
4.0
10A* – 3 pole
14 (2.5)
240V/60Hz/3ph
L1, L2, L3, and ground
4.0
4.5
10A* – 3 pole
14 (2.5)
380V/50Hz/3ph
L1, L2, L3, and ground
2.0
2.5
10A* – 3 pole
14 (2.5)
400-415V/50Hz/3ph
L1, L2, L3, and ground
2.0
2.5
10A* – 3 pole
14 (2.5)
*
3 Phase machines should not have fuses, breakers only.
N/A = Not Applicable
Table 9
Serial Plate Voltage
Terminal Block
Connections Required
Serial Plate
Amps
Recommended Circuit
Breaker Rating
Wire Size
AWG (mm
2
)
120V/60Hz/1ph
L1, Neutral, and ground
16.0
20A – 1 pole
12 (4)
208-240V/60Hz/1ph
L1, L2, Neutral, and ground
8.0
10A – 2 pole
14 (2.5)
100V/60Hz/1ph
L1, Neutral, and ground
22.0
30A – 1 pole
10 (6)
200-220V/60Hz/1ph
L1, Neutral, and ground
11.6
15A – 1 pole
14 (2.5)
100V/50Hz/1ph
L1, Neutral, and ground
24.2
35A – 1 pole
8 (10)
200/50Hz/1ph
L1, Neutral, and ground
15.0
20A – 1 pole
12 (4)
230-240V/50Hz/1ph
L1, Neutral, and ground
9.0
15A – 1 pole
14 (2.5)
200-208V/60Hz/3ph
L1, L2, L3, and ground
6.4
10A* – 3 pole
14 (2.5)
240V/60Hz/3ph
L1, L2, L3, and ground
6.4
10A* – 3 pole
14 (2.5)
200V/50Hz/3ph
L1, L2, L3, and ground
5.8
10A* – 3 pole
14 (2.5)
230-240V/50Hz/3ph
L1, L2, L3, and ground
7.0
10A* – 3 pole
14 (2.5)
380V/50 or 60Hz/3ph
L1, L2, L3, and ground
3.0
10A* – 3 pole
14 (2.5)
400-415V/50Hz/3ph
L1, L2, L3, and ground
3.2
10A* – 3 pole
14 (2.5)
440V/60Hz/3ph
L1, L2, L3, and ground
3.3
10A* – 3 pole
14 (2.5)
460-480V/60Hz/3ph
L1, L2, L3, and ground
3.3
10A* – 3 pole
14 (2.5)
*
3 Phase machines should not have fuses, breakers only.
Table 10