Programming the Hold Step Type
The Hold Step Type allows the owner to pause a cycle at a specif-
ic type to allow user interaction with the cycle, generally to add a
chemical. After selecting the desired Cycle Step number and
pressing START (enter),
XXHoLd
will appear in the display.
Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
) key-
pad to scroll through the options and START (enter) to select a
value.
Step
Type
Diplay A
Display B
Values
Description
XXHoLd
Hold Step Type (
XX
is step number, step type is
flashing)
En diS
XXHo01
EnAbLE
,
diSAbL
,
dNod
1
,
dNod 2
Step Enable/Disable
Choosing
dNod 1
and
dNod 2
will enable the step
if the cycle modifier is chosen and set to be enabled
in
Cycle Modifier Programming CNP-
.
StAtUS
XXHo02
PrEWSH
,
WASH
,
rinSE1
,
rinSE2
,
rinSE3
,
rinSE4
,
SPin
Status LED: The corresponding LED on the control
will be lit during this step.
NinUtE
XXHo03
0-2
Step Minutes: If Programmed Cycle Time Display is
enabled and set to a value greater than zero, it will
override this time.
SECond
XXHo04
0-59
Step Seconds: If Programmed Cycle Time Display is
enabled and set to a value greater than zero, it will
override this time.
AUdioP
XXHo05
0-20
Audio Pattern: The audio will stop once a key is
pressed or the door is opened.
NESSAg
XXHo06
LoAd
,
CHEN
,
SoAP
,
bLEACH
,
SoFtnr
,
SoUr
,
StArCH
,
CUStN1
,
CUStN2
Display Message
StArtP
XXHo07
StrtCy
,
UnLoCK
Door Lock State
AUrESN
XXHo08
0-255
Automatic Resume Minutes: Cycle will resume au-
tomatically after the programmed time only if the
step was programmed to have the door remain
locked.
oUtP 1
XXHo12
oFF
,
on
External Output #1
oUtP 2
XXHo13
oFF
,
on
External Output #2
oUtP 3
XXHo14
oFF
,
on
External Output #3
oUtP 4
XXHo15
oFF
,
on
External Output #4
Table 22
While in the Hold Step, a message is used to indicate what inter-
action the machine is waiting for. The Hold step can be program-
med to either hold water and keep the door locked or to evacuate
water and unlock the door. In both cases a Start key press will al-
low the cycle to resume.
This step may be used to allow the machine to be rinsed out be-
fore adding the next load. An additional vend could be charged
by having a Modifier Key programmed to enable steps to perform
this functionality by setting the steps as Mod 1 or Mod 2. Refer to
Cycle Modifier Programming CNP-
Programming Control
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
86
Part No. 805405ENR5
Содержание BT3JGASG403UW01