To exit the Software Version Number Test, press the DELI-
CATES 30 (<) keypad. The control will return to the Testing
Mode.
Drive Board #1 Software Version Test
d 3
This option displays the drive board software version number. To
start test, control must be in the Testing Mode. Refer to
at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
db1XX
where
XX
is the software version number.
To exit the Drive Board #1 Version Test, press the DELICATES
30 (<) keypad. The control will return to the Testing Mode.
Water Level Trim Test
d 7
This test checks the water level trim value. To start test, control
must be in the Testing Mode. Refer to
at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
triNXX
where XX is the trim value in 0.1 inch precision where
a value of
05
would equal 0.5 inches. If the right most decimal
point is lit, the trim value is negative.
To exit the Water Level Trim Test, press the DELICATES 30 (<)
keypad. The control will return to the Testing Mode.
Service Door Opening Test
d 8
This option tests the service door switch. To start test, control
must be in the Testing Mode. Refer to
at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
S oP
when the service door switch is open and
S CL
when the
service door switch is closed.
The service door switch has to be closed for at least one second
and opened for at least one second for the display to change. This
test will add a count to the service door opening counter for the
audit and save the date/time for each opening.
To exit the Service Door Opening Test, press the DELICATES 30
(<) keypad. The control will return to the Testing Mode.
Coin Vault Opening Test
d 9
This option tests the coin vault switch. To start test, the control
must be in the Testing Mode. Refer to
at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
v oP
when the coin vault switch is open and
v CL
when the
coin vault switch is closed.
The coin vault switch has to be closed for at least one second and
opened for at least one second for the display to change. This test
will add a count to the coin vault opening counter for the audit
and save the time/date for each opening.
To exit the Coin Vault Opening Test, press the DELICATES 30
(<) keypad. The control will return to the Testing Mode.
Coin Drop 1 Input Test
d 10
This option tests coin drop #1. To start test, control must be in the
Testing Mode. Refer to
ginning of this section.
To enter, press the START (enter) keypad. The display will show
C1 XX
. The
XX
will show the number of coins entered and will
increment one for each coin entered in coin drop #1.
NOTE: Coins entered in test mode will not increment
the total # of coins counter that is accessed in the audit
feature.
To exit the Coin Drop #1 Input Test, press the DELICATES 30
(<) keypad. The control will return to the Testing Mode.
Coin Drop 2 Input Test
d 11
This option tests coin drop #2. To start test, control must be in the
Testing Mode. Refer to
ginning of this section.
To enter, press the START (enter) keypad. The display will show
C2 XX
. The
XX
will show the number of coins entered and will
increment one for each coin entered in coin drop #2.
NOTE: Coins entered in test mode will not increment
the total # of coins counter that is accessed in the audit
feature.
To exit the Coin Drop #2 Input Test, press the DELICATES 30
(<) keypad. The control will return to the Testing Mode.
Vend Connection Header Present Test
d 12
This option tests the vend header connection. To start test, control
must be in Testing Mode. Refer to
at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
CH oP
when the wiring connection is open and
CH CL
when the
connection is closed.
To exit Vend Connection Header Present Test, press the DELI-
CATES 30 (<) keypad. The control will return to the Testing
Mode.
Start Pulse Test
d 13
This option tests the Start Pulse. To start test, control must be in
the Testing Mode. Refer to
beginning of this section.
To enter, press the START (enter) keypad. The display will show
St XX
. The
XX
will show the number of pulses entered. This test
Testing Machine and Electronic Control Functions
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
100
Part No. 805405ENR5