7. Burner Ignites and Goes Out Repeatedly
Burner Ignites
and Goes Out
Repeatedly
Is there
insufficient
gas
pressure?
Check gas
supply and
pressure.
Yes
Is the
cabinet
thermostat
inoperative?
Yes
Test thermostat
and replace if
inoperative.
Is the
exhaust system
improper or
inadequate?
Yes
Refer to
Installation
Manual
for
exhaust
system
requirements.
No
No
Does
tumbler have
improper
orifices?
Yes
Tumbler is equipped
for type of gas
specified on serial
plate. If orifices are
different from that
specified on serial
plate, obtain and
install correct
orifices.
No
Is
there excessive
igniter to burner
clearance?
Yes
Refer to
Paragraph 43.
Is
there inadequate
make-up air?
Yes
Refer to
Installation
Manual
for
make-up air
requirements.
No
Is the
thermistor
inoperative?
Yes
No
Replace
thermistor.
Is the control
heater relay
malfunctioning?
Yes
Replace control.
No
Is there
broken, loose
or incorrect
wiring?
Yes
Refer to wiring
diagram.
No
Yes
Repair damper to
working order.
Are the back
draft dampers
locked in close
position?
No