Quantum Control Troubleshooting
58. CE Models No Display
Replace the control.
Is there voltage across
H1-1 and H1-3 on the
control?
Correct wiring
between fuse F4
and control.
Is there voltage coming
out of fuse F4?
Replace fuse.
Is fuse F4 good?
Correct wiring
between
transformer
and fuse.
Check transformer
for operation.
Replace if
necessary.
Is there voltage across
terminals 1 and 4 of
the transformer?
Is line voltage supplied
to the transformer
primary?
Is there
line voltage on the
output side of the
primary fuse?
Replace primary
fuse.
Correct wiring
between primary
fuse and
transformer.
Is there
line voltage on the
input side of primary
fuse?
Verify that unit is
plugged in. Correct
wiring between
supply terminals
and fuse F1.
(1)
(2)
(3)
(4)
(5)
(6)
Yes
No
Yes
No
No
Yes
(2)
Yes
No
Yes
No
Yes
No
No
Yes