Error Codes
Display
Description
Cause/Corrective Action
Ero
Locked rotor error: The motor is not sensed as
rotating when it should be.
Terminate cycle and check that nothing is obstructing
motor rotation. Check wire harness connection
between motor, user control and output board, or try
replacing the user control or the output board. Clear
error with a key press.
Eop
Open thermistor error: The thermistor circuit
is sensed as being physically open.
Remove any lint build up around thermistor. Check
wire harness connection between thermistor and
harness. If problem persists replace thermistor, harness
or output board. Thermistor must no longer be seen as
open to clear.
Esh
Shorted thermistor error: The thermistor
circuit is sensed as being shorted.
Remove any lint build up around thermistor. Check
wire harness connection between thermistor and
harness. If problem persists replace thermistor, harness
or output board. Thermistor must no longer be seen as
shorted to clear.
Ens
Motor output shorted error: Hardware error.
Terminate cycle. Replace output board. Power down
machine to clear.
E59
Door input acquisition error: Hardware error. Terminate cycle. Replace output board. Power down
machine to clear.
E60
Centrifugal switch input acquisition error:
Hardware error.
Terminate cycle. Replace output board. Power down
machine to clear.
E61
High limit thermostat input acquisition error:
Hardware error.
Advance cycle to cool down. Replace output board.
Power down machine to clear.
Eco
Output board communication error:
Communication failure.
Power down machine to clear, power up and try again.
If error persists, check harness connection between
user control and output board, or try replacing the user
control or the output board.
Enr
Output board not ready error: Hardware
failure.
Terminate cycle. Replace output board. Power down
machine to clear.