D515518ENR2
15
Section 3 Troubleshooting
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
6. DRYER HEATING ASSEMBLY DOES NOT HEAT OR BURNER DOES NOT IGNITE
Dryer heating assembly does not
heat or burner does not ignite.
Is exhaust
system
improper or
inadequate?
Refer to
Installation
Instructions
(supplied with
unit) for
exhaust
requirements.
Is exhaust
duct made of
plastic or thin
foil?
No
Replace with
rigid or semi-
rigid metal
exhaust duct.
Yes
Is house fuse
blown or
circuit breaker
tripped?
Check fuses or
circuit breakers.
Yes
Is limit
thermostat
inoperative?
Test
thermostat
and replace if
inoperative.
Yes
Electric Models:
Is heater
assembly
inoperative?
Test heater
assembly
and replace
if cold
Ohms do
not read
between 9
and 10.5
Ohms.
Yes
Electric
Models: Is
thermal fuse
inoperative?
Test thermal
fuse and
replace if
inoperative.
Yes
DRY1874S
Yes
No
Is drive
motor switch
inoperative?
Test switch
and replace if
inoperative.
No
Yes
Continued on
next page.
No
Is temperature
selector switch
set at NO
HEAT/AIR
FLUFF, or
inoperative?
Reset or test
switch and
replace if
inoperative.
No
Yes
No
No
No
Yes
No
Is
timer/
electronic
control improperly
set (set in
a cool-down period,
or a no heat
cycle)?
Reset
timer/electronic
control. Try
another cycle.
DRY1874S