Section 6 Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NOTE: Timer Motor Resistance:
120 Volt, 60 Hz
2,462 – 2,714 Ohms
240 Volt
10,900 – 13,300 Ohms
(4) Rotate timer to “cooldown” (5 minutes
before “OFF”). “Infinite” (open) reading
should be found between L2 and H.
(5) Rotate timer to “OFF” position. “Infinite”
(open) reading should be found between L1
and M and between L2 and H.
21. FABRIC SELECTOR SWITCH
NOTE: Refer to proper model wiring diagram
when rewiring switch.
a. Set test meter to read Ohms and apply meter
probes to switch terminals.
NOTE: Refer to proper model wiring diagram
when reconnecting wires.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
FABRIC SELECTOR SWITCH
–
4 Position
L1-1
L1-2
No Heat/Air Fluff
–
–
Delicate
X
X
Perm. Press
–
X
Regular
–
X
X indicates closed
FABRIC SELECTOR SWITCH
–
3 Position
L1-2
L1-3
L1-1
No Heat/Air Fluff
–
X
–
Delicate/Knits
X
–
X
Regular/Perm. Press
X
–
–
X indicates closed