42
801803
Section 4 Grounding
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
29. GROUND WIRES FROM POWER CORD TO REAR BULKHEAD AND FROM REAR BULKHEAD
TO CONTROL CABINET
Check Wall Receptacle Polarity (Gas Dryer Models Only)
Refer to Figure 2.
Figure 2
D354SE3A
Ground
L1
Neutral
Side
Dryer
Power Cord
115±12
V.A.C.
115±12
V.A.C.
0
V.A.C.
Ground
Wires