801803
99
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
76. CYLINDER ROLLERS
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 27.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
Refer to Figure 35.
c. Remove two screws holding bottom tabs on
front panel to dryer side panels. Refer to
Figure 28. Swing bottom of front panel away
from dryer far enough to disengage hold-down
clips and locators from cabinet top.
d. Disconnect wires from door switch. Refer to
NOTE: Refer to wiring diagram when rewiring
switch.
e. Disengage belt from motor and idler pulleys.
Refer to Figure 43.
f. Remove four screws holding bulkhead to front
flange of cabinet. Then lift complete bulkhead
assembly out of slots in cabinet. Refer to
Figure 48.
IMPORTANT: When reassembling, be sure seal on
exhaust fan cover makes airtight seal on flange of
duct. Refer to Figure 40. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted which can adversely affect dryer
performance.
g. Pull cylinder forward allowing rear of cylinder
to drop down exposing rollers. Refer to
Figure 54.
h. Refer to Figure 54 for removal of roller from
bulkhead.
NOTE: When replacing the cylinder roller, it is
important that cylinder roller is installed with the
flanged surface of the roller bearing facing towards
the front of the dryer.
77. OUTLET COVER
a. Open door and remove two screws holding
outlet cover to rear bulkhead. Refer to
Figure 53.
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
WARNING
Figure 54
Roller
Bracket
Shaft
Screw
Retainer
Ring
Flanged Surface
of Roller Bearing
(Must face toward front of dryer)
Locknut
Washers
Rear
Bulkhead
D260SE3B
Содержание LTS97A*N
Страница 2: ......
Страница 6: ...4 801803 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...
Страница 12: ...10 801803 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...
Страница 14: ...12 801803 Section 3 Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...
Страница 24: ...22 801803 Section 3 Troubleshooting Dryer Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...
Страница 50: ...48 801803 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...
Страница 106: ...104 801803 Section 5 Service Procedures Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...