Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
80. WIRE COVER OR WIRE CHANNEL
COVER PLATE
Refer to Figure 37.
a. Remove single screw holding wire channel
cover plate to wire channel (older models); or
remove six screws holding wire cover to rear of
tumbler (new models).
b. Remove wire cover or wire channel cover plate.
IMPORTANT: When reinstalling cover, make sure
the wires and thermostat sensing tube (if equipped)
are not pinched between rear of cabinet and wire
cover or between cover plate and channel.
81. DRIVE GUARD
a. Support drive guard and remove screws
holding guard to rear of tumbler. Refer to
Figure 37.
b. Reinstall drive guard.
Figure 38
T037SE1A
NEWER MODELS
AIRFLOW
SWITCH
MOUNTING
SCREWS
SWITCH
LEVER
SWITCH
BOX
MOUNTING
BRACKET
MOUNTING
BRACKET
AIRFLOW
SWITCH
ATTACHING
SCREWS
AIRFLOW
SWITCH
PHILLIPS
HEAD
SCREWS
TU038-SV