Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
52. GAS VALVE
(Standing Pilot Models)
a. Remove control panel.
b. Close gas shut-off valve. Refer to Figure 20.
c. Disconnect all wires from gas valve terminals
and disconnect gas valve pipe unions.
d. Disconnect thermocouple and pilot tube from
gas valve.
IMPORTANT: When reinstalling gas valve, use
pipe compound resistant to action of L.P. gas on all
pipe threads.
e. Remove screws holding gas valve and bracket
to stove assembly.
f. Remove nipple from left side of valve and plug
from right side of valve.
53. OPERATOR
(Standing Pilot Models)
a. Remove control panel.
b. Close gas shut-off valve. Refer to Figure 20.
c. Disconnect wires from operator terminals
d. Remove screws holding operator to gas valve
NOTE: Refer to wiring diagram when rewiring gas
valve operator.
54. RESET ASSEMBLY
(Standing Pilot Models)
a. Remove control panel.
b. Close gas shut-off valve. Refer to Figure 20.
c. Disconnect pilot tube and thermocouple from
reset assembly.
d. Remove screws holding reset assembly to gas
valve. Refer to Figure 19.
Figure 20
T016SE3A
PILOT
BURNER
PILOT
TUBE
THERMOCOUPLE
PIPE
UNION
GAS
SHUT-OFF
VALVE
(Shown in the
ON Position)
GAS
VALVE
STANDING PILOT BURNER
To reduce risk of fire or explosion, check
pipe connections for gas leaks with a non-
corrosive leak detection fluid. Do not use an
open flame to check for gas leaks!
W310
WARNING