c. Manual Timers and Coin Meter Models
(1) Remove two screws holding control panel
to cabinet. Refer to Figure 3.
(2) Lift control panel off top edge of front
panel and pull panel forward just far
enough to disconnect wire harness at the
plug.
35. PUSH-TO-START SWITCH
a. Remove control panel.
b. Remove two screws holding switch and
mounting bracket (if applicable) to control
panel. Refer to Figure 3.
c. Disconnect wires from switch terminals and
remove switch.
NOTE: Refer to wiring diagram when rewiring
switch.
36. COOLING, DRYING OR RUN LIGHT
a. Remove control panel.
b. Disconnect light wire leads.
NOTE: On Coin Meter Models, the run light white
lead must be joined to the wire harness white lead
using a double spade connector. Remove the single
spade lug from the replacement run light white
wire. On Coin Slide Models, the run light leads must
be disconnected from the Molex plug. Mark plug
with felt tipped pen to insure proper reconnecting of
the wire leads.
c. Compress locking tabs on sides of light and
push light through front of control panel.
(Refer to Figure 4, Coin Models;
Refer to Figure 5, Manual Timer Models).
NOTE: Refer to wiring diagram when rewiring
light.
Figure 4
TAB
TAB
COIN DROP CONTROL PANEL
RUN LIGHT
T005SE1b
RUN LIGHT
COIN SLIDE CONTROL PANEL