Option
Number
Option
Display
Description
Default
Value
Value Range
7
CHHS3-
Segment 3
-
CHHS31 (Segment 3 Enable/Disable), CHHS32 (Seg-
ment 3 Time), CHHS33 (Segment 3 Temperature),
CHHS34 (Segment 3 Auto Dry Target Level),
CHHS35 (Segment 3 Moisture Dry Target Moisture),
CHHS36 (Segment 3 Reversing Enable/ Disable)
8
CHHS4-
Segment 4
-
CHHS41 (Segment 4 Enable/Disable), CHHS42
(Segment 4 Time), CHHS43 (Segment 4 Tempera-
ture), CHHS44 (Segment 4 Auto Dry Target Level),
CHHS45 (Segment 4 Moisture Dry Target Moisture),
CHHS46 (Segment 4 Reversing Enable/ Disable)
9
CHHS5-
Segment 5
-
CHHS51 (Segment 5 Enable/Disable), CHHS52
(Segment 5 Time), CHHS53 (Segment 5 Tempera-
ture), CHHS54 (Segment 5 Auto Dry Target Level),
CHHS55 (Segment 5 Moisture Dry Target Moisture),
CHHS56 (Segment 5 Reversing Enable/ Disable)
10
CHHCd-
Cool Down
-
CHHCd1 (Cool Down Temperature), CHHCd2 (Cool
Down Time), CHHCd3 (Cool Down Segment Re-
versing Enable/Disable)
11
CHHr-
Reversing
-
CHH r1 (Cycle Reversing Enable/Disable), CHH r2
(Cycle Reversing Rotate Time), CHH r3 (Cycle Re-
versing Stop Time)
2
Cd-
Global Cool Down
-
-
a
Cd 1
Cool Down Temperature
100°F
[38°C]
70°-110°F [21°-43°C]
b
Cd 2
Cool Down Time (minutes)
2
1-15
3
rEu-
Global Reversing Parame-
ters
-
-
a
rEu 1
Rotate Time (seconds)
3 (30)
3-9 (30-540 seconds)
b
rEu 2
Stop Time (seconds)
0 (6)
0-4 (6-10 seconds)
c
rEu 3
Advanced Reversing
0
0 (oFF), 1 (on)
4
tEnP-
Global Temperatures
-
-
a
tEnP 1
Global Very Low Tempera-
ture
120°F
[49°C]
100°-120°F [38°-49°C]
b
tEnP 2
Global Low Temperature
140°F
[60°C]
120°-140°F [49°-60°C](50, 75, 120, 170, 200 Pound
Models), 105°-145°F [41°-63°C](25, 30, T30 Pound
Models),125°-155°F [52°-68°C](35, T45, 55 Pound
Models)
Table continues...
Programming Control
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
28
Part No. 70444901ENR10
Содержание CHD25E2-CT025E
Страница 2: ......