Rapid Advance Mode
If the Rapid Advance Option is enabled, the user can advance a
running machine cycle by pressing the Start keypad. In a Time
Dry cycle, pressing the Start keypad will decrease the remaining
time by one minute. Pressing and holding the Start keypad will
decrease the remaining time by four minutes per second until the
end of the cycle.
In the Auto-Dry and Moisture Dry cycles, pressing the Start key-
pad will advance the cycle to the next enabled segment. Note that
Auto-Dry cycles only have one programmable segment.
In the Cool Down segment, pressing the Start keypad will de-
crease the remaining time by one minute.
When the cycle is completed, the audit counter, Total Rapid Ad-
vance Cycles, is incremented rather than the Total Machine Cy-
cles audit counter. If the Rapid Advance Option is disabled pre-
venting a manual Rapid Advance, the user may still execute a
Rapid Advance using the PDA or PC. Refer to
PC and PDA Ap-
plication User Instructions
for additional information on using a
PDA or PC to Rapid Advance a cycle.
Pause Mode
If Stop keypad is pressed or the loading or lint door is opened
while in Run Mode, control enters Pause Mode.
If the door was opened to enter Pause Mode, the control will
show
door
until the door is closed or Pause Mode is exited. If
the door is closed, the control will show
PUSH
for one second
followed by
StArt
for one second as well as flash the Start key-
pad LED one second on/one second off.
If the Stop keypad was pressed to enter Pause Mode and the load-
ing door is closed, the control will show
PAUSE
until Pause
Mode is exited.
Any time
PAUSE
is shown on the control, the Start keypad LED
will flash one second on/one second off to prompt the user to re-
start the cycle.
Error Mode
This mode will be entered to display all fatal machine errors.
Communication Mode
This mode is entered whenever the control is communicating
with a PDA. Refer to
PC and PDA Application User Instruc-
tions
.
Cool Down Mode
The control enters the Cool Down Mode after the heat segment of
the cycle is completed or fatal error occurs. The control turns the
heater off and for steam heated units turns the damper motor on.
The cool down segment will end once the cool down temperature
has been reached or the programmed cool down time expires,
which ever happens first.
End of Cycle Mode
The control enters End of Cycle Mode after the cool down seg-
ment is finished. The display will toggle between
LoAd
and
rEAdy
for one second each until End of Cycle Mode is exited. If
the door has not been opened or a keypad has not been pressed
after two minutes, the machine will enter Extended Tumble
Mode. This mode is exited when the door is opened or Stop key-
pad is pressed. The control will then return to Idle Mode.
Extended Tumble Mode
The Extended Tumble Mode has two portions. The Anti-Wrinkle
Tumble is entered two minutes after the cycle has ended if the
door is not opened. The cylinder will tumble for 30 seconds every
two minutes for up to one hour.
If the door hasn’t been opened and no keys have been pressed
one hour after the Anti-Wrinkle Tumble has ended, the control in-
crements the Anti-Wrinkle Time Exceeded audit counter and en-
ters Delayed Tumble. The cylinder will tumble for two minutes
every 60 minutes for up to 18 hours.
Reversing Mode (reversing models only)
Models equipped with the reversing feature will rotate in the for-
ward direction, pause, rotate in the reverse direction and then
pause for programmable times and segments of the cycle. Factory
default reversing rotate time is 30 seconds and reversing stop
time is 6 seconds for all cycles with reversing enabled.
Entering Diagnostic Mode From Idle Mode
When entered from the Idle Mode, the control will be running a
test selected by the user via keypad presses or communication
with a device.
Displaying Temperature Mode
The temperature can be displayed during an active cycle by
pressing the up arrow or down arrow to scroll through the menu.
Select A:(Temp Value) to see the actual or current temperature.
Select P:(Temp Value) to see the programmed temperature.
Control Identification
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
23