Preliminary Information
About the Control
This control is an advanced, programmable computer that lets the
owner control most machine features by pressing a sequence of
keypads.
The control allows the owner to program custom cycles, run di-
agnostic cycles, and retrieve audit and error information.
Tumble Dryers shipped from the factory have default cycles and
other settings built in. The owner can change the default cycle or
any cycle.
IMPORTANT: It is extremely important that the tumble
dryer has a positive ground and that all mechanical
and electrical connections are made before applying
power to or operating the tumble dryer.
DIP Switch Configuration
Make sure DIP switches are configured properly for the machine.
Refer to
TMB1445R_SVG
Figure 1
Power Failure Recovery
If a cycle is in progress when the power fails, and if the power
outage lasts three or more seconds, the cycle is lost and cannot be
resumed when power recovers. If the power outage lasts less than
three seconds, the control will resume the cycle when the power
recovers.
Communications
The control has the ability to communicate with a PDA and a lap-
top with an IrDA device running the control software. Devices
such as PDAs and laptops that are IrDA capable (able to transmit
information to machine) that have been tested and approved for
use with the software can be used as a tool for managing the ma-
chine.
Audit Information
The control collects and stores audit information, which can be
accessed with a PDA or PC. Refer to the following list for some
of the available audit information. Refer to
PC and PDA Appli-
cation User Instructions
.
• End of Cycle to Loading Door Open Time
• End of Cycle to Start of Next Cycle Time
• Total Number of Machine Cycles
• Total Number of Operating Minutes
• Power Failure Audit Data
The PDA or PC can receive audit and program data from the con-
trol, and send programming data and diagnostic commands to the
control. Refer to
PC and PDA Application User Instruction
s
for additional information.
Some of the above listed audit data is available manually. Refer
to
section.
Restore to Factory Defaults
When the user resets to factory default, the control resets all of
the default values. The control also resets Machine Cycles #1
through #30. The control will also reset the following to factory-
defaults:
Default Global Settings
Ignition Retries = 3
Temperature Units = Fahrenheit (°F)
High (H) Temperature = 190 (°F)
Medium (M) Temperature = 160 (°F)
Low (L) Temperature = 140 (°F)
Very Low (VL) Temperature = 120 (°F)
Cool Down Temperature = 100 (°F)
Cool Down Time = 2 (minutes)
Rapid Advance = Disabled
Multi-Segment Cycles = Disabled
Daylight Saving = Enabled
Key Pad Audio = Enabled
End of Cycle Audio = Enabled (5 seconds)
Preliminary Information
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
18
Part No. 70444901ENR10
Содержание CHD25E2-CT025E