background image

Dimensional Clearances - Side-by-Side Mount - 20-60 Pound [9.1-27.2 Kg] Models, in. [mm]

Description

20

30

40

60

A

Distance to wall (minimum)

24 [610]

24 [610]

24 [610]

24 [610]

B

Mounted without bases (mini-
mum)

5.14 [131]

5.12 [130]

4.63 [118]

4.06 [103]

Mounted with bases (mini-
mum)

5.5 [139]

5.5 [139]

4.88 [124]

4.44 [112]

C

Length of pad (minimum)

34.8 [884]

39.5 [1003]

43.5 [1105]

50.6 [1285]

D

Width of pad (minimum)

57.54 [1462]

63.52 [1613]

67.38 [1711]

78.98 [2006]

E

Side clearance between ma-
chines

.5 [13]

.5 [13]

.5 [13]

.5 [13]

Table 13

Installation

©

 Copyright, Alliance Laundry Systems LLC -

 DO NOT COPY or TRANSMIT

  47

  Part No. F8619501ENR11

Содержание BCA Series

Страница 1: ...s Refer to Page 9 for Machine Identification Original Instructions Keep These Instructions for Future Reference CAUTION Read the instructions before using the machine If this machine changes ownership this manual must accompany machine www alliancelaundry com Part No F8619501ENR11 September 2022 ...

Страница 2: ......

Страница 3: ... radiator and your body Limited Channels Fixed For Use In USA IEEE 802 11b or 802 11g or 802 11n HT20 operation of this product in the U S is firmware limited to Channel 1 through 11 CANADA CAN ICES 3 B NMB 3 B This device contains license exempt transmitter s receiver s that comply with Innovation Science and Economic Develop ment Canada s license exempt RSS s standards Operation is subject to th...

Страница 4: ...nt has complied with NCC regulations According to Administrative Regulations of Low Power Radio Waves Radiated Devices Article 12 The low power radio frequency devices must not be altered by changing the frequency enhancing emission power adding external antenna and modification of original design characteristic as well as function Article 14 The operation of the low power radio frequency devi ces...

Страница 5: ...table is prepared in accordance with the provisions of SJ T 11364 O Indicates that the content of said hazardous substance in all of the homogenous materials in the component is within the limits required by GB T 26572 X Indicates that the content of said hazardous substance exceeds the limits required by GB T 26572 in at least one homogenous material in the component All parts named in this table...

Страница 6: ...lean ing solvents flammable chemicals thinners or other flamma ble or explosive substances These substances give off vapors that could ignite explode or cause the fabric to catch fire by itself Under certain conditions hydrogen gas may be produced in a hot water system that has not been used for two weeks or more HYDROGEN GAS IS EXPLOSIVE If the hot water system has not been used for such a period...

Страница 7: ...conditions which can produce bodily injury and or property damage NOTE The WARNINGS and IMPORTANT SAFETY IN STRUCTIONS appearing in this manual are not meant to cover all possible conditions and situations that may occur Common sense caution and care must be exer cised when installing maintaining or operating the washer Any problems or conditions not understood should be reported to the dealer dis...

Страница 8: ...rlock before starting operation of the ma chine a Attempt to start the machine with the door open The ma chine should not start b Close the door without locking it and start the machine The machine should not start c Attempt to open the door while a cycle is in progress The door should not open If the door lock and interlock are not functioning properly dis connect power and call a service technic...

Страница 9: ...r 43 Elevated Pad Installation on Existing Floor 43 Elevated Base Frame Installation on Existing Floor 43 New Foundation 43 Isolated Pad Installation 43 Foundation and Pad Installation 44 Floor Layout and Pad Dimensions 45 Foundation Requirements 54 Machine Mounting and Grouting 58 Drain Connection Requirements 61 Drain Hose Models Connect Drain Hose to Drain Receptacle 64 Water Connection Require...

Страница 10: ...with F Control 100 HCT SCA SCD SCG SCH SCJ SCT SCU UCA UCD UCG UCH UCJ UCT and UCU Models with N Control 100 BCG HCA HCD HCG HCH HCJ HCT HCU PCG SCA SCG SCT UCA UCD UCG UCH UCJ UCT and UCU Models with Q Control 100 Vend Control Instructions 102 BCG HCT and PCG Models with N and W Controls 102 SCA SCE SCG SCJ and SCU Models with N and W Controls 102 DCJ HCT SCH and SCT Models with N and W Controls ...

Страница 11: ...020NL HCE020NQ HCE020NT HCE020NV HCE020NX HCE020NY HCE020WC HCE020WD HCE020WE HCE020WF HCE020WH HCE020WL HCE020WQ HCE020WT HCE020WV HCE020WX HCE020WY HCG020FN HCG020NC HCG020ND HCG020NE HCG020NF HCG020NH HCG020NL HCG020NQ HCG020NT HCG020NV HCG020NX HCG020NY HCG020QN HCG020WC HCG020WD HCG020WE HCG020WF HCG020WH HCG020WL HCG020WT HCG020WV HCG020WX HCG020WY HCH020FN HCH020NC HCH020ND HCH020NE HCH020N...

Страница 12: ...NH SCH020NL SCH020NN SCH020NQ SCH020NT SCH020NV SCH020NX SCH020NY SCH020WC SCH020WD SCH020WE SCH020WF SCH020WH SCH020WL SCH020WQ SCH020WT SCH020WV SCH020WX SCH020WY SCJ020FN SCJ020NN SCJ020WC SCJ020WD SCJ020WE SCJ020WF SCJ020WH SCJ020WL SCJ020WQ SCJ020WT SCJ020WV SCJ020WX SCJ020WY SCK020FN SCK020NC SCK020ND SCK020NE SCK020NF SCK020NH SCK020NL SCK020NN SCK020NQ SCK020NT SCK020NV SCK020NX SCK020NY S...

Страница 13: ...0NY HCE030WC HCE030WD HCE030WE HCE030WF HCE030WH HCE030WL HCE030WQ HCE030WT HCE030WV HCE030WX HCE030WY HCG030FN HCG030NC HCG030ND HCG030NE HCG030NF HCG030NH HCG030NL HCG030NQ HCG030NT HCG030NV HCG030NX HCG030NY HCG030QN HCG030WC HCG030WD HCG030WE HCG030WF HCG030WH HCG030WL HCG030WT HCG030WV HCG030WX HCG030WY HCH030FN HCH030NC HCH030ND HCH030NE HCH030NF HCH030NH HCH030NL HCH030NQ HCH030NT HCH030NV ...

Страница 14: ...NH SCH030NL SCH030NN SCH030NQ SCH030NT SCH030NV SCH030NX SCH030NY SCH030WC SCH030WD SCH030WE SCH030WF SCH030WH SCH030WL SCH030WQ SCH030WT SCH030WV SCH030WX SCH030WY SCJ030FN SCJ030NN SCJ030WC SCJ030WD SCJ030WE SCJ030WF SCJ030WH SCJ030WL SCJ030WQ SCJ030WT SCJ030WV SCJ030WX SCJ030WY SCK030FN SCK030NC SCK030ND SCK030NE SCK030NF SCK030NH SCK030NL SCK030NN SCK030NQ SCK030NT SCK030NV SCK030NX SCK030NY S...

Страница 15: ...0NF HCH040NH HCH040NL HCH040NQ HCH040NT HCH040NV HCH040NX HCH040NY HCH040QN HCH040WC HCH040WD HCH040WE HCH040WF HCH040WH HCH040WL HCH040WQ HCH040WT HCH040WV HCH040WX HCH040WY HCJ040FN HCJ040NC HCJ040ND HCJ040NE HCJ040NF HCJ040NH HCJ040NL HCJ040NQ HCJ040NT HCJ040NV HCJ040NX HCJ040NY HCJ040QN HCJ040WC HCJ040WD HCJ040WE HCJ040WF HCJ040WH HCJ040WL HCJ040WQ HCJ040WT HCJ040WV HCJ040WX HCJ040WY HCK040NH ...

Страница 16: ...NH SCK040NL SCK040NN SCK040NQ SCK040NT SCK040NV SCK040NX SCK040NY SCK040WC SCK040WD SCK040WE SCK040WF SCK040WH SCK040WL SCK040WQ SCK040WT SCK040WV SCK040WX SCK040WY SCL040FN SCL040NC SCL040ND SCL040NE SCL040NF SCL040NH SCL040NL SCL040NN SCL040NQ SCL040NT SCL040NV SCL040NX SCL040NY SCL040WC SCL040WD SCL040WE SCL040WF SCL040WH SCL040WL SCL040WQ SCL040WT SCL040WV SCL040WX SCL040WY SCT040FN SCT040NC S...

Страница 17: ...0NF HCH060NH HCH060NL HCH060NQ HCH060NT HCH060NV HCH060NX HCH060NY HCH060QN HCH060WC HCH060WD HCH060WE HCH060WF HCH060WH HCH060WL HCH060WQ HCH060WT HCH060WV HCH060WX HCH060WY HCJ060FN HCJ060NC HCJ060ND HCJ060NE HCJ060NF HCJ060NH HCJ060NL HCJ060NQ HCJ060NT HCJ060NV HCJ060NX HCJ060NY HCJ060QN HCJ060WC HCJ060WD HCJ060WE HCJ060WF HCJ060WH HCJ060WL HCJ060WQ HCJ060WT HCJ060WV HCJ060WX HCJ060WY HCK060NH ...

Страница 18: ...NH SCK060NL SCK060NN SCK060NQ SCK060NT SCK060NV SCK060NX SCK060NY SCK060WC SCK060WD SCK060WE SCK060WF SCK060WH SCK060WL SCK060WQ SCK060WT SCK060WV SCK060WX SCK060WY SCL060FN SCL060NC SCL060ND SCL060NE SCL060NF SCL060NH SCL060NL SCL060NN SCL060NQ SCL060NT SCL060NV SCL060NX SCL060NY SCL060WC SCL060WD SCL060WE SCL060WF SCL060WH SCL060WL SCL060WQ SCL060WT SCL060WV SCL060WX SCL060WY SCT060FN SCT060NC S...

Страница 19: ...0WD HCH080WE HCH080WF HCH080WH HCH080WL HCH080WQ HCH080WT HCH080WV HCH080WX HCH080WY HCJ080FN HCJ080NC HCJ080ND HCJ080NE HCJ080NF HCJ080NH HCJ080NL HCJ080NQ HCJ080NT HCJ080NV HCJ080NX HCJ080NY HCJ080QN HCJ080WC HCJ080WD HCJ080WE HCJ080WF HCJ080WH HCJ080WL HCJ080WQ HCJ080WT HCJ080WV HCJ080WX HCJ080WY HCK080NH HCT080FN HCT080NC HCT080ND HCT080NE HCT080NF HCT080NH HCT080NL HCT080NQ HCT080NT HCT080NV ...

Страница 20: ...K080NH SCK080NL SCK080NN SCK080NQ SCK080NT SCK080NV SCK080NX SCK080NY SCK080WC SCK080WD SCK080WE SCK080WF SCK080WH SCK080WL SCK080WQ SCK080WT SCK080WV SCK080WX SCK080WY SCT080FN SCT080NC SCT080ND SCT080NE SCT080NF SCT080NH SCT080NL SCT080NN SCT080NT SCT080NQ SCT080NV SCT080NX SCT080NY SCT080QC SCT080QD SCT080QE SCT080QF SCT080QH SCT080QL SCT080QN SCT080QQ SCT080QT SCT080QV SCT080QX SCT080QY SCT080...

Страница 21: ...0WD HCH100WE HCH100WF HCH100WH HCH100WL HCH100WQ HCH100WT HCH100WV HCH100WX HCH100WY HCJ100FN HCJ100NC HCJ100ND HCJ100NE HCJ100NF HCJ100NH HCJ100NL HCJ100NQ HCJ100NT HCJ100NV HCJ100NX HCJ100NY HCJ100QN HCJ100WC HCJ100WD HCJ100WE HCJ100WF HCJ100WH HCJ100WL HCJ100WQ HCJ100WT HCJ100WV HCJ100WX HCJ100WY HCK100NH HCT100FN HCT100NC HCT100ND HCT100NE HCT100NF HCT100NH HCT100NL HCT100NQ HCT100NT HCT100NV ...

Страница 22: ...CK100NH SCK100NL SCK100NN SCK100NQ SCK100NT SCK100NV SCK100NX SCK100NY SCK100WC SCK100WD SCK100WE SCK100WF SCK100WH SCK100WL SCK100WQ SCK100WT SCK100WV SCK100WX SCK100WY SCT100FN SCT100NC SCT100ND SCT100NE SCT100NF SCT100NH SCT100NL SCT100NN SCT100NT SCT100NQ SCT100NV SCT100NX SCT100NY SCT100QC SCT100QD SCT100QE SCT100QF SCT100QH SCT100QL SCT100QN SCT100QQ SCT100QT SCT100QV SCT100QX SCT100QY SCT10...

Страница 23: ...eking technical assistance Refer to Figure 1 Model Example of Serial Plate Location 1 Serial Plate on Panel 2 Serial Plate on Door Frame Figure 1 Replacement Parts If literature or replacement parts are required contact the source from which the machine was purchased or contact Alliance Laun dry Systems at 1 920 748 3950 for the name and address of the nearest authorized parts distributor Customer...

Страница 24: ... 78 2 20 105 2 97 112 3 17 Slat crate shipping dimensions WxDxH in mm 32 5 x 36 8 x 55 826 x 935 x 1397 36 0 x 41 3 x 55 0 914 x 1049 x 1397 37 0 x 45 9 x 55 0 940 x 1166 x 1397 42 0 x 49 9 x 64 0 1067 x 1267 x 1626 48 5 x 57 5 x 65 1 1232 x 1461 x 1654 48 5 x 61 5 x 65 1 1232 x 1562 x 1654 Wash Cylinder Information Cylinder diameter in mm 21 0 533 24 0 610 26 3 668 30 0 762 36 0 914 36 0 914 Cyli...

Страница 25: ...h extract RPM G 648 125 606 125 579 125 542 125 495 125 495 125 Very high extract RPM G 710 150 664 150 635 150 594 150 542 150 542 150 Ultra high extract RPM G 819 200 766 200 733 200 686 200 626 200 568 165 Direct Steam Heating Optional Steam inlet connection size in NPT N A N A 1 2 1 2 1 2 1 2 Number of steam inlets N A N A 1 1 1 1 Maximum pressure psi kPa N A N A 85 570 85 570 85 570 85 570 Re...

Страница 26: ...s 3 3 6 6 6 6 Electrical heat element size kW 2 6 2 6 2 6 2 6 4 2 4 2 Time required to raise bath temperature minutes per 10 F 5 5 C LOW 1 690 2 545 1 792 2 648 2 101 2 436 MED 2 048 3 119 2 187 2 902 2 268 2 843 HIGH 2 368 3 693 2 394 3 269 2 643 3 031 Noise Emissions dBA Wash 58 58 58 58 60 64 Extract 100G 56 56 58 60 67 69 Extract 200G 61 65 65 65 73 73 N A Not Applicable Table 1 Specifications...

Страница 27: ...Machine Dimensions Front View CHM2563N_SVG Figure 2 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 27 Part No F8619501ENR11 ...

Страница 28: ...1 30 9 785 30 9 785 C 17 0 432 17 0 432 17 7 450 18 1 460 21 7 551 21 7 551 D 14 4 366 14 0 356 14 6 371 14 9 378 17 9 378 17 9 378 E 26 0 660 29 0 737 30 6 777 34 1 866 41 5 1054 41 5 1054 F 1 1 28 1 1 28 1 1 28 1 1 28 1 1 28 1 1 28 Table 2 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 28 Part No F8619501ENR11 ...

Страница 29: ...Side View CHM2564N_SVG Figure 3 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 29 Part No F8619501ENR11 ...

Страница 30: ...27 3 693 31 8 808 37 0 940 39 5 1003 44 1 1120 48 1 1222 D 30 9 785 35 3 897 42 3 1074 44 7 1135 47 1 1196 51 1 1298 E 9 3 236 9 3 236 9 3 236 9 3 236 9 3 236 9 3 236 Door width 16 75 426 19 38 492 21 75 552 21 75 552 25 25 641 25 25 641 Table 3 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 30 Part No F8619501ENR11 ...

Страница 31: ...rical 3 7 8 Electrical 4 7 8 Electrical 5 Compartment Cold Fill Valve 6 Compartment Hot Fill Valve 7 Cold Hard Water Valve or 3rd Water Inlet 8 Pump Drain View Figure 4 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 31 Part No F8619501ENR11 ...

Страница 32: ...8 960 D 33 8 859 35 8 909 E 3 9 99 4 3 109 F 7 8 198 9 3 236 G 2 0 51 2 0 51 H 18 1 460 21 1 536 J 20 7 526 23 7 602 K 23 1 587 26 1 663 L 39 4 1001 41 4 1052 M 35 6 904 37 5 953 Table 4 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 32 Part No F8619501ENR11 ...

Страница 33: ...7 8 Electrical 4 7 8 Electrical 5 Steam Valve 6 Compartment Cold Fill Valve 7 Compartment Hot Fill Valve 8 Cold Hard Water Valve or 3rd Water Inlet 9 Pump Drain View Figure 5 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 33 Part No F8619501ENR11 ...

Страница 34: ...1067 C 40 3 1024 D 38 0 965 E 4 5 114 F 8 8 224 G 17 0 432 H 2 0 51 J 22 8 579 K 25 4 645 L 27 7 704 M 39 7 1008 N 43 6 1107 P 43 5 1105 Table 5 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 34 Part No F8619501ENR11 ...

Страница 35: ...rical 4 7 8 Electrical 5 Tub Cold Fill Valve 6 Tub Hot Fill Valve 7 Steam Valve 8 Compartment Cold Fill Valve 9 Compartment Hot Fill Valve 10 Cold Hard Water Valve or 3rd Water Inlet Figure 6 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 35 Part No F8619501ENR11 ...

Страница 36: ...28 8 732 28 8 732 H 2 0 51 2 0 51 2 0 51 J 21 0 533 28 4 721 28 4 721 K 22 5 572 29 9 759 29 9 759 L 26 2 665 33 6 853 33 6 853 M 28 8 732 36 2 919 36 2 919 N 31 2 792 38 6 980 38 6 980 P 46 3 1176 52 6 1336 52 6 1336 Q 42 4 1077 49 7 1262 49 7 1262 R 46 3 1176 53 6 1361 53 6 1361 S 42 4 1097 49 7 1262 49 7 1262 Table 6 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT CO...

Страница 37: ...to Table 7 CHM2609N_SVG Q L P O N M K J I F G H E C B D A R 2 1 A 3 1 Elevated Base Width 2 Front of Mounting Bolt Template 3 Machine Width Figure 7 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 37 Part No F8619501ENR11 ...

Страница 38: ...1 12 28 1 033 26 G 2 15 55 1 81 46 H 2 71 69 2 37 60 I 2 8 71 2 813 71 J 4 5 114 4 51 114 K 9 638 245 10 5 267 L 20 649 525 23 5 597 M 0 113 3 0 188 5 N 23 938 608 28 938 735 O 24 69 627 29 69 754 P 27 95 710 32 38 597 Q 26 660 29 737 R 0 641 16 0 641 16 Table 7 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 38 Part No F8619501ENR11 ...

Страница 39: ... Models 40 and 60 Models refer to Table 8 1 Elevated Base Width 2 Front of Mounting Bolt Template 3 Machine Width Figure 8 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 39 Part No F8619501ENR11 ...

Страница 40: ... 11 0 614 16 G 1 98 50 1 75 44 H 2 37 60 2 37 60 I 3 1 79 3 28 83 J 4 63 118 4 96 126 K 12 5 318 11 927 303 L 23 626 600 27 5 699 M 1 187 30 1 25 32 N 32 5 826 36 914 O 33 54 852 36 87 699 P 37 36 949 40 7 1034 Q 30 6 777 34 1 866 R 0 641 16 0 641 16 Table 8 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 40 Part No F8619501ENR11 ...

Страница 41: ...achines installed back to back use the outside bolt holes marked A For multiple machines installed side by side with minimum clearance use the inside bolt holes marked B 1 Front of Mounting Bolt Template Figure 9 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 41 Part No F8619501ENR11 ...

Страница 42: ...0 508 13 I 1 96 50 1 96 50 J 3 38 86 3 38 86 K 0 94 24 0 94 24 L 16 406 16 406 M 35 889 35 889 N 37 28 947 37 28 947 O 42 16 1071 42 16 1071 P 49 54 1258 49 54 1258 Q 4 102 4 102 AA Outside 42 72 1085 42 72 1085 BB Inside 35 43 900 35 43 900 CC Outside 52 86 1342 52 86 1342 DD Inside 47 16 1197 47 16 1197 Table 9 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or T...

Страница 43: ...e without voids under slab and meet depth requirements per Table 20 If the floor meets these requirements and an elevated pad is NOT desired re fer to Figure 18 and proceed to Machine Mounting and Grouting If the floor does not meet these requirements and an elevated pad is NOT desired refer to Figure 21 and proceed to Machine Mounting and Grouting Elevated Pad Installation on Existing Floor The e...

Страница 44: ... 152 Table 11 IMPORTANT Do NOT install a pad on top of the exist ing floor The foundation and pad must be constructed and tied together as one piece If the existing floor is not reinforced concrete at least 12 inches 305 mm thick an elevated pad is desired or multiple machines are to be installed the following steps must be performed refer to Foundation Requirements 1 Cut a hole through the existi...

Страница 45: ...chor bolts as the concrete is poured refer to Figure 23 and Table 24 14 Proceed to Machine Mounting and Grouting Floor Layout and Pad Dimensions Dimensional Clearances Single Machine Mount 20 60 Pound 9 1 27 2 Kg Models refer to Table 12 CHM2504N_SVG 1 2 3 4 5 A C C B B D E 1 Wall 2 Rear Edge of Pad 3 Side Edge of Pad 4 Machine 1 5 Front Edge of Pad Figure 11 Dimensional Clearances Single Machine ...

Страница 46: ...81 71 5 18 131 D Length of pad minimum 34 8 884 39 5 1003 43 5 1105 50 6 1285 E Width of pad minimum 31 4 798 34 4 874 36 5 927 44 8 1138 Table 12 Dimensional Clearances Side by Side Mount 20 60 Pound 9 1 27 2 Kg Models refer to Table 13 CHM2505N_SVG C D 1 2 E 3 5 2 4 5 A B B 1 Wall 2 Rear Edge of Pad 3 Machine 1 4 Machine 2 5 Front Edge of Pad Figure 12 Installation Copyright Alliance Laundry Sys...

Страница 47: ...5 14 131 5 12 130 4 63 118 4 06 103 Mounted with bases mini mum 5 5 139 5 5 139 4 88 124 4 44 112 C Length of pad minimum 34 8 884 39 5 1003 43 5 1105 50 6 1285 D Width of pad minimum 57 54 1462 63 52 1613 67 38 1711 78 98 2006 E Side clearance between ma chines 5 13 5 13 5 13 5 13 Table 13 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 47 Part No F8619501ENR11 ...

Страница 48: ...onal Clearances Back to Back Mount 20 60 Pound 9 1 27 2 Kg Models in mm Description 20 30 40 60 A Adjacent rear bolt spacing minimum 28 3 719 27 6 702 28 0 710 27 5 699 B Distance from front bolt to edge of pad minimum 5 26 134 5 26 134 6 19 157 8 9 226 C Length of pad minimum 88 63 2251 98 37 2499 115 23 2927 119 48 3035 Table 14 continues Installation Copyright Alliance Laundry Systems LLC DO NO...

Страница 49: ...927 44 8 1138 Table 14 Dimensional Clearances Single Machine Mount 80 and 100 Pound 36 3 and 45 4 Kg Models refer to Table 15 CHM2519N_SVG D E 1 2 3 4 5 A C C B B 1 Wall 2 Rear Edge of Pad 3 Side Edge of Pad 4 Machine 1 5 Front Edge of Pad Figure 14 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 49 Part No F8619501ENR11 ...

Страница 50: ... minimum 24 610 B Distance of machine base to edge of pad minimum 4 98 126 C Distance of machine base to edge of pad minimum 8 203 D Length of pad minimum 49 2 1250 E Width of pad minimum 57 5 1461 Table 15 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 50 Part No F8619501ENR11 ...

Страница 51: ...chine 2 5 Front Edge of Pad Figure 15 Standard Mount Side by Side 80 and 100 Pound 36 3 and 45 4 Kg Models in mm Description 80 100 A Distance to wall minimum 24 610 B Adjacent unit spacing minimum 6 152 C Length of pad minimum 49 2 1250 D Width of pad minimum 99 5 2527 Table 16 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 51 Part No F8619501ENR11 ...

Страница 52: ...36 3 and 45 4 Kg Models in mm Description 80 100 A Distance to wall minimum 24 610 B Adjacent unit bolt spacing minimum 10 38 264 C Length of pad minimum 49 2 1250 D Width of pad minimum 99 5 2527 IMPORTANT When close mounting bolt machine using inside bolt holes Table 17 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 52 Part No F8619501ENR11 ...

Страница 53: ...nt facing Edge of Pad 2 Machine 2 3 Rear of Machine 4 Machine 1 5 Side Edge of Pad or Wall Figure 17 Back to Back Mount 80 and 100 Pound 36 3 and 45 4 Kg Models in mm Description 80 100 A Adjacent rear spacing minimum 33 3 846 Table 18 continues Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 53 Part No F8619501ENR11 ...

Страница 54: ...bolt to edge of pad minimum 8 94 227 Table 18 Pad Thickness Requirements in mm Specification 20 30 40 60 80 100 Minimum Foun dation Thickness F speed 4 102 4 102 4 102 4 102 6 152 V speed 4 102 4 102 6 152 6 152 9 229 Minimum Exca vation Depth F speed 8 203 8 203 8 203 8 203 12 305 V speed 8 203 8 203 12 305 12 305 15 381 Table 19 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or ...

Страница 55: ...0 40 60 F speed 40 60 V speed 80 100 F speed 80 100 V speed A Required thickness of existing floor minimum 4 102 4 102 6 152 9 229 Table 20 New Monolithic Floor refer to Table 21 PHM981N_SVG 2 3 B A 1 1 1 Edge of Pad 2 3500 PSI minimum Concrete 3 Compacted Fill minimum 6 in 152 mm beneath machine Figure 19 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 55 Part No F8619...

Страница 56: ...F speed 80 100 V speed A Depth of Surrounding Floor 4 102 4 102 6 152 9 229 B Total depth of foundation con crete plus 6 in 152 mm fill minimum 10 254 10 254 12 305 15 381 Table 21 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 56 Part No F8619501ENR11 ...

Страница 57: ... of elevated pad above floor maximum 8 203 8 203 8 203 8 203 B Distance between reinforcing bars maximum 12 305 12 305 12 305 12 305 C Length of reinforcing bar ex tending into existing floor mini mum 2 5 64 2 5 64 2 5 64 2 5 64 D Total depth of foundation con crete plus 6 in 152 mm fill minimum 10 254 10 254 12 305 15 381 E Required thickness of existing floor minimum 4 102 4 102 6 152 9 229 Tabl...

Страница 58: ...V speed 80 100 F speed 80 100 V speed A Required thickness of existing floor minimum 4 102 4 102 6 152 9 229 B Total depth of foundation con crete plus 6 in 152 mm fill minimum 10 254 10 254 12 305 15 381 C Distance between reinforcing bars minimum 12 305 12 305 12 305 12 305 D Length of reinforcing bar ex tending into existing floor mini mum 2 5 64 2 5 64 2 5 64 2 5 64 Table 23 Installation Copyr...

Страница 59: ...il all voids are filled IMPORTANT Minimum Grade 5 SAE rating flat washers and minimum Grade 5 SAE rating serrated hex flange locknuts are the recommended hardware for anchoring machine or elevated base frame to an chor bolts 11 Position the flat washers and locknuts on the anchor bolts and finger tighten to machine base or elevated base frame 12 Allow machine grout to set but not cure IMPORTANT Re...

Страница 60: ...chine Frame Base 2 Grout 1 2 in 13 mm 3 Acrylic Adhesive 4 Anchor Bolt minimum Grade 5 SAE rating 5 Concrete 6 Drill Hole Size per Manufacturer Requirements 7 Edge of Pad Figure 22 Cast in place Anchors refer to Table 24 CHM2438N_SVG 5 A D E B C 1 2 4 3 1 Machine Frame Base 2 Grout 3 Anchor Bolt minimum Grade 5 SAE rating 4 Concrete 5 Edge of Pad Figure 23 Installation Copyright Alliance Laundry S...

Страница 61: ...rame to floor Table 24 Floor Load Data Specification 20 30 40 60 80 100 Static floor load lbs kN 430 1 91 550 2 45 690 3 07 920 4 09 1590 7 07 1690 7 51 Static pressure lbs ft 2 kN m 2 97 4 64 95 4 55 98 4 69 105 5 03 140 6 70 149 7 13 Dynamic floor load lbs kN 420 1 86 630 2 80 840 3 74 1260 5 61 1680 7 48 1680 7 48 Dynamic floor pressure lbs ft2 kN m 2 96 4 60 109 5 22 119 5 70 143 6 85 149 7 13...

Страница 62: ... to the 3 inches 76 mm schedule 40 PVC plumbing If proper drain size is not available or practical a surge tank is required A surge tank along with a sump pump should be used when gravity drainage is not possible Drain Trough System CHM2379N_SVG 1 2 3 4 5 6 7 1 Rear of Machine 2 Drain Pipe 3 Steel Grate 4 Drain Trough 5 Strainer 6 Waste Line 7 1 in 25 mm minimum gap Figure 24 Installation Copyrigh...

Страница 63: ...fication 20 30 40 60 80 100 Drain connection size in 3 3 3 3 3 3 Overflow drain connection size in 1 1 2 2 1 4 2 1 4 2 1 4 2 1 4 2 1 4 Number of drain outlets 1 1 1 1 1 1 Drain flow capacity gal min l min 25 95 30 114 40 151 50 189 55 208 55 208 Maximum discharge level 30 gal l 11 2 42 23 9 90 27 4 104 30 8 117 43 4 165 53 3 202 Recommended drain pit size ft 3 l 2 0 57 2 5 71 3 5 128 5 7 161 8 0 2...

Страница 64: ...per minute lit ers per minute 3 ft 0 9 m 9 4 35 5 5 ft 1 5 m 7 6 28 8 6 ft 1 8 m 6 6 25 1 7 ft 2 1 m 5 6 21 2 8 ft 2 4 m 4 3 16 4 Water Connection Requirements WARNING To prevent personal injury avoid contact with inlet water temperatures higher than 125 Fahrenheit 51 Celsius and hot surfaces W748 The maximum water inlet temperature for vended models is 125 F 51 C and the recommended maximum water...

Страница 65: ...ot Cold 1 3 4 3 4 2 1 3 4 3 1 1 4 1 4 1 1 2 1 Table 28 Suitable air cushions risers should be installed in supply lines to prevent hammering Refer to Figure 26 Alliance Laundry Systems LLC ranges of front loading commer cial clothes washing machines have solenoid valves at the inlets The water supply to the washing machines is supplied with an AB air gap between the soap tray and the drum Minimum ...

Страница 66: ...Fig ure 29 4 Screw hose couplings with the filter screens onto the water supply faucets until they are finger tight Use the red color coded hose for the hot water connection and the blue color coded hose for the cold water connection 5 Using pliers screw approximately 1 4 turn 6 Screw the coupling with the plain rubber washer of the red color coded hose attached to the hot water connection onto th...

Страница 67: ... water connection 6 Using pliers screw approximately 1 4 turn 7 Screw the coupling with the plain rubber washer of one 1 of the red color coded hoses attached to the hot water connec tion onto the main fill valve inlet marked with a red label Screw the coupling with the plain rubber washer of the other red color coded hose onto the tub fill valve inlet marked with a red label Tighten to finger tig...

Страница 68: ...in Fill 5 Rubber Washer plain 6 Red Fill Hose hot 7 Hose Coupling 8 Hot Water Supply Faucet 9 Cold Water Supply Faucet 10 Y connection 11 Filter Screen screen must be facing outward toward water supply 12 Blue Fill Hose cold Figure 30 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 68 Part No F8619501ENR11 ...

Страница 69: ...Plumbing Diagrams 20 60 Models Side View refer to Table 29 Figure 31 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 69 Part No F8619501ENR11 ...

Страница 70: ...20 60 Models Rear View refer to Table 29 CHM2641N_SVG 1 Vacuum Breaker Overflow Figure 32 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70 Part No F8619501ENR11 ...

Страница 71: ... operating water level 18 5 470 17 0 432 19 9 505 C Vaccum breaker overflow 33 9 861 35 8 909 38 0 965 D Vaccum breaker overflow centerline 35 5 902 37 5 953 39 7 1008 E Inlet Valves 38 9 988 41 4 1052 43 2 1097 Table 29 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 71 Part No F8619501ENR11 ...

Страница 72: ...60 100 Models Side View refer to Table 30 Figure 33 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 72 Part No F8619501ENR11 ...

Страница 73: ...60 100 Models Rear View refer to Table 30 1 1 Vacuum Breaker Overflow Figure 34 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 73 Part No F8619501ENR11 ...

Страница 74: ...ARNING Hazardous Voltage Can cause shock burn or death Verify that a ground wire from a proven earth ground is connected to the lug near the input power block on this machine W360 WARNING This Machine produces excessive leakage current Do not use a grounding conductor smaller than 10mm 2 W946 NOTE For voltages above or below listed specifica tion a qualified electrical contractor must be consulted...

Страница 75: ...ents For voltages above or below listed specifications contact your power company or local electrician IMPORTANT Improper connections will result in equip ment damage and will void warranty DANGER Electrical shock hazard will result in death or serious injury Disconnect electric power and wait five 5 mi nutes before servicing W810 Circuit Breakers and Quick Disconnects Single phase machines requir...

Страница 76: ... the ON and OFF positions IMPORTANT Where an emergency stop is required by local ordinances a disconnect must be installed that is readily accessible to all users NOTE Installation of models in North America recom mended installation is hard wired without a GFCI If a GFCI is mandatory due to local requirements then the GFCI must be rated for 30mA or higher Single Phase Connections For single phase...

Страница 77: ...r pipes WARNING Electrically heated machines DO NOT require dual power sources Do not connect customer power or customer load to the Internal Load Distribution ter minal block Refer to the machine electrical schemat ic for details W759 Machines with Electric Heat 1 Grounding Lug Connect to proven earth ground 2 Customer Input Power Terminals Figure 39 Machines without Electric Heat 1 Grounding Lug...

Страница 78: ...n Specifications Code Voltage Cycle Phase Wire Full Load Amps Circuit Breaker AWG mm 2 F Speed Models B 120 60 1 2 8 15 14 2 5 W 200 240 50 1 3 2 3 4 3 15 14 2 5 Y 200 240 60 1 3 2 3 4 3 15 14 2 5 X 200 240 50 60 1 3 2 3 4 3 15 14 2 5 Q Electric Heat 200 240 50 60 3 3 22 30 10 6 0 P Standard 380 415 50 60 3 3 2 15 14 2 5 Electric Heat 12 15 14 2 5 N Standard 440 480 50 60 3 3 2 15 14 2 5 Electric ...

Страница 79: ...cifications Code Voltage Cycle Phase Wire Full Load Amps Circuit Breaker AWG mm 2 N Standard 440 480 50 60 3 3 2 15 14 2 5 Electric Heat 14 15 14 2 5 Table 32 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 79 Part No F8619501ENR11 ...

Страница 80: ...rd 380 415 50 60 3 3 3 15 14 2 5 Electric Heat 12 15 14 2 5 N 440 480 50 60 3 3 3 15 14 2 5 14 15 14 2 5 V Speed Models B 120 60 1 2 12 15 12 4 W 200 240 50 1 3 2 3 7 4 15 14 2 5 Y 200 240 60 1 3 2 3 7 4 15 14 2 5 X 200 240 50 60 1 3 2 3 7 4 15 14 2 5 Q Electric Heat 200 240 50 60 3 3 22 30 10 6 0 P Standard 380 415 50 60 3 3 3 15 14 2 5 Electric Heat 12 15 14 2 5 N Standard 440 480 50 60 3 3 3 15...

Страница 81: ...50 60 3 3 3 15 14 2 5 Electric Heat 24 30 10 6 0 N Standard 440 480 50 60 3 3 3 15 14 2 5 Electric Heat 22 30 10 6 0 V Speed Models B 120 60 1 2 12 15 12 2 5 W 200 240 50 1 2 3 7 4 15 14 2 5 Y 200 240 60 1 3 2 3 7 4 15 14 2 5 X 200 240 50 60 1 3 2 3 7 4 15 14 2 5 Q Electric Heat 200 240 50 60 3 3 41 50 8 10 0 P Standard 380 415 50 60 3 3 3 15 14 2 5 Electric Heat 24 30 10 6 0 N Standard 440 480 50...

Страница 82: ... 60 3 3 4 15 14 2 5 Electric Heat 26 30 10 6 0 N Standard 440 480 50 60 3 3 4 15 14 2 5 Electric Heat 22 30 10 6 0 V Speed Models X 200 240 50 60 1 3 2 3 11 7 15 14 2 5 Q Electric Heat 200 240 50 60 3 3 41 50 8 10 0 P Standard 380 415 50 60 3 3 4 15 14 2 5 Electric Heat 26 30 10 6 0 N Standard 440 480 50 60 3 3 4 15 14 2 5 Electric Heat 22 30 10 6 0 Table 35 Installation Copyright Alliance Laundry...

Страница 83: ... 3 3 5 15 14 2 5 Electric Heat 33 40 8 10 0 N Standard 440 480 50 60 3 3 5 15 14 2 5 Electric Heat 36 40 8 10 0 V Speed Models X 200 240 50 60 1 3 2 3 15 9 20 15 12 14 4 2 5 Q Electric Heat 200 240 50 60 3 3 73 80 4 25 0 P Standard 380 415 50 60 3 3 6 15 14 2 5 Electric Heat 33 40 8 10 0 N Standard 440 480 50 60 3 3 6 15 14 2 5 Electric Heat 36 40 8 10 0 Table 36 Installation Copyright Alliance La...

Страница 84: ... 3 3 5 15 14 2 5 Electric Heat 32 40 8 10 0 N Standard 440 480 50 60 3 3 5 15 14 2 5 Electric Heat 36 40 8 10 0 V Speed Models X 200 240 50 60 1 3 2 3 16 10 20 15 12 14 4 2 5 Q Electric Heat 200 240 50 60 3 3 74 80 4 25 0 P Standard 380 415 50 60 3 3 6 15 14 2 5 Electric Heat 32 40 8 10 0 N Standard 440 480 50 60 3 3 6 15 14 2 5 Electric Heat 36 40 8 10 0 Table 37 Installation Copyright Alliance L...

Страница 85: ...sectional area shall be provided up to a point where the protective conductor has a cross sectional area not less than 10 mm2 Cu 20 Models CE Approval Voltage Designation Specifications Code Voltage Cycle Phase Wire Full Load Amps Circuit Breaker mm 2 F Speed Models B 120 60 1 2 8 10 2 5 W 200 240 50 1 3 2 3 4 3 6 2 5 Y 200 240 60 1 3 2 3 4 3 6 2 5 X 200 240 50 60 1 3 2 3 4 3 6 2 5 Q Electric Heat...

Страница 86: ... 17 20 25 2 5 P Standard 380 415 50 60 3 3 3 6 2 5 Electric Heat 11 16 2 5 N 440 480 50 60 3 3 3 6 2 5 V Speed Models B 120 60 1 2 12 16 2 5 W 200 240 50 1 3 2 3 7 4 10 6 2 5 Y 200 240 60 1 3 2 3 7 4 10 6 2 5 X 200 240 50 60 1 3 2 3 7 4 10 6 2 5 Q Electric Heat 220 240 50 60 3 3 17 20 25 2 5 P Standard 380 415 50 60 3 3 3 6 2 5 Electric Heat 11 16 2 5 N 440 480 50 60 3 3 3 6 2 5 Table 39 Installat...

Страница 87: ...5 50 60 3 3 3 6 2 5 Electric Heat 23 25 2 5 N Standard 440 480 50 60 3 3 3 6 2 5 Electric Heat 20 25 2 5 V Speed Models B 120 60 1 2 12 16 2 5 W 200 240 50 1 3 2 3 7 4 10 6 2 5 Y 200 240 60 1 3 2 3 7 4 10 6 2 5 X 200 240 50 60 1 3 2 3 7 4 10 6 2 5 Q Electric Heat 200 240 50 60 3 3 33 39 50 10 0 P Standard 380 415 50 60 3 3 3 6 2 5 Electric Heat 23 32 2 5 N Standard 440 480 50 60 3 3 3 6 2 5 Electr...

Страница 88: ...380 415 50 60 3 3 4 6 2 5 Electric Heat 23 32 2 5 N Standard 440 480 50 60 3 3 4 6 2 5 Electric Heat 20 25 2 5 V Speed Models X 200 240 50 60 1 3 2 3 11 7 16 10 2 5 Q Electric Heat 200 240 50 60 3 3 33 39 50 10 0 P Standard 380 415 50 60 3 3 4 6 2 5 Electric Heat 23 32 2 5 N Standard 440 480 50 60 3 3 4 6 2 5 Electric Heat 20 25 2 5 Table 41 Installation Copyright Alliance Laundry Systems LLC DO N...

Страница 89: ...15 50 60 3 3 5 6 2 5 Electric Heat 30 40 4 0 N Standard 440 480 50 60 3 3 5 6 2 5 Electric Heat 35 40 4 0 V Speed Models X 200 240 50 60 1 3 2 3 17 11 20 16 2 5 Q Electric Heat 200 240 50 60 3 3 59 70 80 16 0 P Standard 380 415 50 60 3 3 7 10 2 5 Electric Heat 30 40 4 0 N Standard 440 480 50 60 3 3 7 10 2 5 Electric Heat 35 40 4 0 Table 42 Installation Copyright Alliance Laundry Systems LLC DO NOT...

Страница 90: ...415 50 60 3 3 5 6 2 5 Electric Heat 30 40 4 0 N Standard 440 480 50 60 3 3 5 6 2 5 Electric Heat 35 40 4 0 V Speed Models X 200 240 50 60 1 3 2 3 17 11 20 16 2 5 Q Electric Heat 220 240 50 60 3 3 59 70 80 16 0 P Standard 380 415 50 60 3 3 7 10 2 5 Electric Heat 30 40 4 0 N Standard 440 480 50 60 3 3 7 10 2 5 Electric Heat 35 40 4 0 Table 43 Installation Copyright Alliance Laundry Systems LLC DO NO...

Страница 91: ...e machine and void the warranty The chemical supply connector is located on the back right hand side of the machine There are 12 chemical ports on the connec tor through each a liquid supply hose can be connected A flush manifold system can only be connected through the top 6 ports refer to Figure 42 IMPORTANT Water pressure must not exceed 40 psi 275 kPa 1 Drill through the ports on the chemical ...

Страница 92: ...Figure 42 for detail of chemical supply connector C CHM1N1_SVG1 1 Chemical Supply Connector 2 External Liquid Supply Connection Ports 12 Figure 41 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 92 Part No F8619501ENR11 ...

Страница 93: ...A flush manifold system can only be connected through the top 6 ports boxed 1 3 4 inch port O D 2 1 2 inch port O D 3 3 8 inch port O D Figure 42 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 93 Part No F8619501ENR11 ...

Страница 94: ... available but require some wiring changes and must be provided with an external power source Under no circumstances should the high voltage machine supply connections or source be used for the communication wiring Communication wiring connections which is H2 a single row green connector on a small output board can be found under a service panel at the upper back of the machine Chemical Injection ...

Страница 95: ...al supplies must not be derived from the high voltage main power connection point IMPORTANT The external power must supply power of 240VAC or less and be protected at 3 Amps or less 1 Disconnect and cap off the Red and White 24VAC wires 2 Connect one side of the external power to the RELAY COM and the other to the external dispenser input signals common Refer to Figure 46 and Figure 47 CHM2573N_SV...

Страница 96: ...gnal board if ES1 is selected the K1 contact will close and power will be supplied to Supply 1 Signal The contact will remain closed for the amount of time programmed in control Refer to Figure 48 for Internal Supply Connection or Figure 50 for External AC Connection For example of an 8 signal board if ES1 is selected the K12 con tact will close and power will be supplied to Supply 1 Signal The co...

Страница 97: ...r supply 2 K12 Contact 3 Supply 1 Signal Figure 50 1 ES1 Power supply 2 K12 Contact 3 Supply 1 Signal Figure 51 Installation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 97 Part No F8619501ENR11 ...

Страница 98: ...ck that basket rotation is counter clockwise in the ex tract step 1 If rotation is not counter clockwise disconnect power to ma chine 2 Have a qualified electrician reverse any two motor leads at the motor Start Up Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 98 Part No F8619501ENR11 ...

Страница 99: ... nets to prevent drain blockage IMPORTANT To prevent out of balance conditions premature wear or damage to machine when using laundry nets use several small nets in a load 4 Close the door and turn handle counter clockwise Refer to Figure 54 CHM2244N_SVG Figure 54 5 Refer to OPL Control Instructions to select and start a cycle CAUTION Water cannot be extracted from rubber backed items To avoid dam...

Страница 100: ... SCH SCJ SCT SCU UCA UCD UCG UCH UCJ UCT and UCU Models with N Control Figure 56 1 If equipped with an optional supply dispenser add dry sup plies to the compartment cups prior to the start of each cycle Liquid supplies can be injected directly into the supply dis penser by an external chemical supply system NOTE Supply dispenser compartment cups must not be removed when an external chemical injec...

Страница 101: ...spenser Refer to Table 45 a Detergent Liquid Compartment 1 prewash Compartment 3 Powder Compartment 1 prewash Compartment 2 b Bleach Liquid Compartment 3 Powder Compartment 2 c Softener Liquid Compartment 4 3 Press the START enter keypad to select NOTE Cycles cannot be changed anytime after the machine is started 4 When a cycle is complete the control displays OPEN DOOR Operation Copyright Allianc...

Страница 102: ...ored 6 When a cycle is complete the control displays OPEN DOOR SCA SCE SCG SCJ and SCU Models with N and W Controls Figure 59 1 Press the Normal 90C Normal 60C Normal 40C Perminant Press 60C Delecates 30C or Delecates Cold keypad to select the desired cycle temperature The corresponding LED indi cates the selection 2 Press the A keypad to run the selected cycle with no modifi ers Press the B and o...

Страница 103: ...tment 3 Powder Compartment 2 c Softener Liquid Compartment 4 6 Press the START enter keypad to select NOTE Cycles can be changed anytime during the first Fill Step After the first Fill Step all cycle key pad presses are ignored 7 When a cycle is complete the control displays OPEN DOOR HCA HCD HCE HCH HCJ and HCU Models with N and W Controls CHM1795C_SVG Rinse Wash Insert Coins Card Spin Door START...

Страница 104: ... prewash Compartment 3 Powder Compartment 1 prewash Compartment 2 b Bleach Liquid Compartment 3 Powder Compartment 2 c Softener Liquid Compartment 4 4 Press the START enter keypad to select NOTE Cycles cannot be changed anytime after the machine is started 5 When a cycle is complete the control displays OPEN DOOR HCT Models with Q Control CHM1794C_SVG Rinse Wash Spin Door Hot Warm Cold Heavy Hot Q...

Страница 105: ...gnored 5 When a cycle is complete the control displays OPEN DOOR Adding Supplies a DETERGENT CHM2228N_SVG 1 1 Liquid Detergent CHM2227N_SVG 2 2 Powder Detergent b BLEACH CHM2229N_SVG 3 3 Liquid Bleach CHM2230N_SVG 4 4 Powder Bleach c SOFTENER CHM2231N_SVG 5 5 Liquid Softener Table 45 Operation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 105 Part No F8619501ENR11 ...

Страница 106: ...on Figure 64 1 Press red emergency stop button to stop all action 2 To restart the machine pull red emergency stop button out and press START enter on the control Operation Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 106 Part No F8619501ENR11 ...

Страница 107: ...and interlock are not functioning properly dis connect power and call a service technician 2 Check the machine for leaks a Start an unloaded cycle to fill the machine b Verify that door and door gasket do not leak c Verify that the drain valve is operating and that the drain system is free from obstruction If water does not leak out during the first wash segment the drain valve is closed and funct...

Страница 108: ...ap H042I_SVG 2 1 1 Cap 2 Steam Filter Element Figure 65 4 For electric heat models only inspect heating elements for ex cess debris by rotating basket to view them through its perfo rations Remove drain valve hose to access and clear debris with pliers Replace element s if necessary NOTE Lint buildup may take several months to oc cur Inspect heating elements a minimum of every 6 months 5 For 80 an...

Страница 109: ... eyebolt top nut until the prop er belt gauge refer to Table 47 is obtained mid span Torque jam nut to spring bracket to 20 6 2 ft lbs Refer to Figure 66 Spring Length Tighten eyebolt top nut until the spring measures the correct distance between the hooks Refer to Table 46 Torque jam nut to spring bracket to 20 6 2 ft lbs Refer to Figure 66 Spring Length in mm Model Distance Between Hooks 20 2 HP...

Страница 110: ...0 All 357 Table 48 d Tighten door hinges and fasteners if necessary 7 Place a large magnet over the normally closed ball switch to verify the stability switch operation 8 Ensure all panels and guards are properly reinstalled a Verify that the drain motor shield is in place and secure if so equipped 9 Run factory test reference programming manual for proce dure details and components tested NOTE Re...

Страница 111: ... of the rust may be an iron or steel part not made of stainless steel such as a nail or screw Remove discoloration or heat tint from overheating by scour ing with a powder or by employing special chemical solu tions Do not leave sterilizing solutions on stainless steel equipment for prolonged periods of time When an external chemical supply is used ensure no siphon ing of chemicals occurs when the...

Страница 112: ...ent En suring this product is disposed of correctly will help prevent po tential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact the local city office household wast...

Отзывы: