![Alliance Laundry Systems BCA Series Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/alliance-laundry-systems/bca-series/bca-series_installation-operation-and-maintenance_2901651057.webp)
)
PHM852N_SVG
1
2
3
B
C
E
D
A
4
5
1.
Existing Floor
2.
3500 PSI (minimum) Concrete
3.
Reinforcing Bar
4.
Perimeter Reinforcing Bar
5.
Compacted Fill (minimum 6 in. [152 mm] )
Figure 20
Elevated Pad, in. [mm]
Description
20-30
40-60 (F-speed)
40-60 (V-speed) /
80-100 (F-speed)
80-100 (V-
speed)
A
Height of elevated pad above
floor (maximum)
8 [203]
8 [203]
8 [203]
8 [203]
B
Distance between reinforcing
bars (maximum)
12 [305]
12 [305]
12 [305]
12 [305]
C
Length of reinforcing bar ex-
tending into existing floor (mini-
mum)
2.5 [64]
2.5 [64]
2.5 [64]
2.5 [64]
D
Total depth of foundation (con-
crete plus 6 in. [152 mm] fill)
(minimum)
10 [254]
10 [254]
12 [305]
15 [381]
E
Required thickness of existing
floor (minimum)
4 [102]
4 [102]
6 [152]
9 [229]
Table 22