66
512176
Section 6 Adjustments
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
63. BURNER FLAME (Gas Models)
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to
.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to
c. Set timer to 60 minutes.
d. Close the loading door. Start the dryer in a heat
setting (refer to Operating Instructions supplied
with the dryer). The dryer will start, the igniter
will glow red, and the main burner will ignite.
e. Allow the dryer to operate for approximately
five minutes, then loosen the air shutter
lockscrew. Refer to
.
f. Turn the air shutter to the left to get a luminous
yellow tipped flame, then turn it back slowly to
the right to obtain a steady blue flame.
g. After proper flame is obtained, tighten air
shutter lockscrew firmly. Refer to
h. Reinstall access panel and screws.
NOTE: After the dryer has operated for
approximately three minutes, exhaust air or
exhaust pipe should be warm.
To reduce the risk of fire or serious injury,
the access panel must be in place during
normal operation.
W262
WARNING
Figure 43
Air Shutter
Lockscrew
Air
Shutter
Shut-Off Valve
Handle
(Shown in open position)
1/8 Inch Pipe Plug
(For checking manifold pressure)
D265SE3A