60
512176
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
(7) Lift cabinet top to a vertical position by
hinging it on the rear hold-down brackets.
Refer to
.
NOTE: When servicing, cabinet top may be raised
and hinged on the rear hold-down brackets or
supported against wall behind dryer.
(8) Carefully withdraw wire harness through
hole in cabinet top and lift the top off the
rear hold-down brackets.
NOTE: Retainer clips hold the wire harness to the
side panel of the dryer. Remove these before
attempting to withdraw wire harness.
(9) Set cabinet top aside.
(10) Disengage belt from motor and idler
.
NOTE: When reinstalling belt, be sure belt is
properly installed on motor and idler pulleys and is
on the correct side of the idler lever. Refer to
. Belt must be positioned around center
section of cylinder approximately three inches
ahead of rear rib on cylinder with the ribbed
surface of the belt against the cylinder. Refer to
. After installing belt, manually rotate
cylinder counterclockwise to check that belt is
properly aligned.
(11)
Models with Cylinder Light
– Disconnect
wires from light receptacle terminals.
(12)
Models with Cylinder Light
– Disconnect
wire clip from front bulkhead.
(13) Remove four screws holding front
bulkhead to dryer. Refer to
(a) Remove front bulkhead.
(b) Remove cylinder.
NOTE: When reassembling the front bulkhead to
the cabinet, hold glides in position with finger tips
on the edges of glides. Once bulkhead is in place,
inspect the glide position with a mirror to ensure the
glides are aligned with the cylinder, making sure the
tabs are visible. Refer to
.
IMPORTANT: During reinstallation of front
bulkhead, be sure that air duct is properly
positioned with flange inside the seal on blower fan
cover. Refer to
. If the duct or seal is
installed improperly, the airflow through the dryer
will be reduced which can cause fire and dryer
malfunction.
(14)
For Gas Models:
(a) Disconnect igniter wires at disconnect
blocks, sensor wires from sensor
terminals, and wires from gas valve
coils at the quick disconnect blocks.
Refer to
(b) Remove screw from right side of burner
housing holding burner tube in place.
Refer to
(c) Gently move burner tube toward rear of
dryer to disengage tab from slot on left
side of burner housing. Refer to
.
(d) Carefully rotate burner tube and igniter
counterclockwise
so tab is at the 8
o’clock position.
(e) Move air shutter end of burner tube
slightly to right and CAREFULLY
remove burner tube and igniter
assembly out through front of dryer.
NOTE: The igniter is very fragile. Be careful not to
damage it during removal.
To reduce the risk of serious injury or
death by carbon monoxide and other
gases in gas dryers, carefully read and
follow all instructions given in this section.
W005
WARNING