PAGE
16
www.allfett.net
PUMP MAINTENANCE
2. IF PUMP NOT SENDING GREASE
1. IF PUMP NOT STARTS
Electrical connections of the pump may be loosen or broken. Check the electrical cables and connections
of the system according to schemas on page 9 and page 10.
Connected electricity to pump may different then DC voltage. Connect the electricity 12 or 24 V DC
which is marked on pump sticker.
Connected electericity may be converted to DC voltage from AC voltage by a transformer.
Transformer must be minimum 5A current.
If pump has low level indicator ;
Control unit (PLC or integrated control card) may give failure and stops the pump because of the grease
inside pump decreased under minimum level. Fill the reservoir according to items 10, 11, 12, 13, 14,
15 and 16 in RULES TO COMPLY WHILE USING AND WARRANTY CONDITIONS.
If ALLFETT control card is connected the system ;
Electronic control card may be in waiting period. Wait until working time starts.
If necessary control card pass to working period by pressing
ADDITIONAL CYCLE
button.
a.
b.
c.
d.
e.
Grease inside pump decreased under minimum level. Fill the reservoir according to items 10, 11, 12,
13, 14, 15 and 16 in RULES TO COMPLY WHILE USING AND WARRANTY CONDITIONS.
Pump elements may take air due to work without grease ;
Read and apply PUMP ELEMENT MAINTENANCE information on page 14.
a.
b.
Unouthorized modifications to the units and the use of unouthorized spare parts and
aids prohobited and disqualify the warranty.
TECHNICAL SERVICE
Содержание ALL-1 PS
Страница 23: ...PAGE 22 www allfett net NOTES ...
Страница 24: ......